Citations

Mayo Clinic

Clear

53 citation(s) found for "Yao, Joseph".

1426Correlation of Cytomegalovirus Viral Load between a Laboratory-Developed Test and a WHO-Calibrated Commercial Assay in Transplant Recipients
Lahr, Brian D. , Yao, Joseph D. , Hata, D. Jane , Dioverti, M. Veronica , Grys, Thomas E. , Razonable, Raymund R.

Open Forum Infectious Diseases | February 3, 2017 | Volume: 1 | Issue: suppl_1 | Pages: S375-S375

10.1093/ofid/ofu052.972 Get It

Cytomegalovirus DNA in Transplant Recipients: Comparison of Whole Blood and Plasma Viral Loads
Dioverti, M. Veronica , Lahr, Brian D. , Germer, Jeffrey J., Yao, Joseph D. , Razonable, Raymund R. , Dioverti, Maria Veronica

Open Forum Infectious Diseases | February 1, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.1839 Get It

Cytomegalovirus (CMV) Deoxyribonucleic Acid (DNA) Quantification in Bronchoalveolar Lavage Fluid Collected From Immunocompromised Patients With CMV Pneumonia
Germer, Jeffrey J., Lahr, Brian D. , Binnicker, M. J., Yao, Joseph D. , Beam, Elena , Limper, Andrew H. , Razonable, Raymund R.

Open Forum Infectious Diseases | February 1, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw194.18 Get It

Prime, Shock, and Kill: Priming CD4 T Cells from HIV Patients with a BCL-2 Antagonist before HIV Reactivation Reduces HIV Reservoir Size
Sainski, Amy M., Dai, Haiming , Natesampillai, Sekar, Pang, Yuan‐Ping , Bren, Gary D., Correia, Maria Cristina Miranda de Araujo, Sampath, Rahul , Rizza, Stacey A. , O’Brien, Daniel R. , Yao, Joseph D. , Badley, Andrew D. , Correia, Cristina , Cummins, Nathan W. , de Araujo Correia, Maria Cristina Miranda, Kaufmann, Scott H. , Correia, Maria Cristina Miranda de Araujo, Correia, Cristina , Badley, Andrew D , Pang, Yuan-Ping , Dai, Haiming

Journal of Virology | February 4, 2016 | Volume: 90 | Issue: 8 | Pages: 4032-4048

10.1128/jvi.03179-15 | PMID 26842479 Get It

ABSTRACT Understanding how some HIV-infected cells resist the cytotoxicity of HIV replication is crucial to enabling HIV cure efforts. HIV killing of CD4 T cells that replicate HIV can involve HIV protease-mediated cleavage of procaspase 8 to generate a fragment (Casp8p41) that directly binds and activates the mitochondrial proapoptotic protein BAK. Here, we demonstrate that Casp8p41 also binds with nanomolar affinity to the antiapoptotic protein Bcl-2, which sequesters Casp8p41 and prevents apoptosis. Further, we show that central memory CD4 T cells (T CM ) from HIV-infected individuals have heightened expression of BCL-2 relative to procaspase 8, possibly explaining the persistence of HIV-infected T CM despite generation of Casp8p41. Consistent with this hypothesis, the selective BCL-2 antagonist venetoclax induced minimal killing of uninfected CD4 T cells but markedly increased the death of CD4 T cells and diminished cell-associated HIV DNA when CD4 T cells from antiretroviral therapy (ART)-suppressed HIV patients were induced with αCD3/αCD28 to reactivate HIV ex vivo . Thus, priming CD4 T cells from ART suppressed HIV patients with a BCL-2 antagonist, followed by HIV reactivation, achieves reductions in cell-associated HIV DNA, whereas HIV reactivation alone does not. IMPORTANCE HIV infection is incurable due to a long-lived reservoir of HIV + memory CD4 T cells, and no clinically relevant interventions have been identified that reduce the number of these HIV DNA-containing cells. Since postintegration HIV replication can result in HIV protease generation of Casp8p41, which activates BAK, causing infected CD4 T cell death, we sought to determine whether this occurs in memory CD4 T cells. Here, we demonstrate that memory CD4 T cells can generate Casp8p41 and yet are intrinsically resistant to death induced by diverse stimuli, including Casp8p41. Furthermore, BCL-2 expression is relatively increased in these cells and directly binds and inhibits Casp8p41's proapoptotic effects. Antagonizing BCL-2 with venetoclax derepresses this antagonism, resulting in death, preferentially in HIV DNA containing cells, since only these cells generate Casp8p41. Thus, BCL-2 antagonism is a clinically relevant intervention with the potential to reduce HIV reservoir size in patients.
Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory
Mitchell, P. Shawn, Mandrekar, Jayawant N. , Yao, Joseph D. , Yao, Joseph D C

Journal of Clinical Microbiology | May 15, 2014 | Volume: 52 | Issue: 7 | Pages: 2689-2693

10.1128/jcm.00430-14 | PMID 24829247 Get It

ABSTRACT Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved.
Evaluation of the Abbott HBV RUO Sequencing Assay Combined with Laboratory-Modified Interpretive Software
Germer, Jeffrey J., Abraham, Priya , Mandrekar, Jayawant N. , Yao, Joseph D.

Journal of Clinical Microbiology | October 25, 2012 | Volume: 51 | Issue: 1 | Pages: 95-100

10.1128/jcm.02155-12 | PMID 23100352 Get It

ABSTRACTThe Abbott HBV RUO Sequencing assay (Abbott Molecular Inc., Des Plaines, IL), which combines automated sample processing, real-time PCR, and bidirectional DNA sequencing, was evaluated for detection of nucleos(t)ide analogue (NA) resistance-associated mutations located in the hepatitis B virus (HBV) polymerase (Pol) gene. Interpretive software from the assay manufacturer was modified to allow interrogation of the overlapping HBV surface (S) gene sequence for HBV genotype determination and detection of immune escape mutations. Analytical sensitivity (detection and sequencing) of the assay was determined to be 103.9 IU/ml (95% confidence interval [CI], 80.0 to 173.3) for HBV genotype A. Testing of commercially available HBV genotype panels consisting of 23 individual members yielded complete agreement between expected results and results obtained from the laboratory-developed HBV genotype library. Excellent specificity was observed among clinical specimens with serologic or molecular markers for various unrelated blood-borne viruses (n= 6) and sera obtained from healthy, HBV-negative blood donors (n= 20). Retrospectively selected clinical specimens tested by a commercial reference laboratory HBV sequencing assay (n= 54) or the TrugeneHBVGenotyping kit (n= 7) and the Abbott HBV RUO Sequencing assay showed minor differences in detection and reporting of NA resistance-associated mutations in 7 of 61 (11.5%) specimens but complete agreement of genotype results. The Abbott HBV RUO Sequencing assay provided a convenient and efficient assay workflow suitable for routine clinical laboratory use, with the flexibility to be modified for customized detection of NA resistance-associated mutations, HBV genotype determination, and detection of immune escape mutations from a single contiguous HBV sequence.
Hepatitis C Virus Genotypes in Clinical Specimens Tested at a National Reference Testing Laboratory in the United States
Germer, Jeffrey J., Mandrekar, Jayawant N. , Bendel, Jordan L., Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | May 26, 2011 | Volume: 49 | Issue: 8 | Pages: 3040-3043

10.1128/jcm.00457-11 | PMID 21613437 Get It

ABSTRACTHepatitis C virus (HCV) genotype (GT) distribution and frequency were studied among 22,407 unique specimens tested at a national reference testing laboratory. Subjects with HCV GT 3 were younger (P< 0.0001) than those with GT 1, 2, or 4, and the regional frequencies of HCV GT 2 and 3 ranged from 19.9% to 29.2%.
Results of the Abbott RealTi m e HIV-1 Assay for Specimens Yielding “Target Not Detected” Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test
Germer, Jeffrey J., Yao, Joseph D. , Babady, N. Esther

Journal of Clinical Microbiology | December 31, 2009 | Volume: 48 | Issue: 3 | Pages: 969-971

10.1128/jcm.01394-09 | PMID 20042629 Get It

ABSTRACT No significantly discordant results were observed between the Abbott RealTi m e HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding “target not detected” results by CTM.
Detection and Quantification of Hepatitis C Virus (HCV) by MultiCode-RTx Real-Time PCR Targeting the HCV 3′ Untranslated Region
Mulligan, Elizabeth K., Germer, Jeffery J., Arens, Max Q., D'Amore, Krista L., Bisceglie, Adrian M. Di , Ledeboer, Nathan A., Moser, Michael J., Newman, Andrew, O'Guin, Andy K., Olivo, Paul D. , Podzorski, Diane, Vaughan, Kimberly A., Yao, Joseph D. , Elagin, Slava, Johnson, Scott C.

Journal of Clinical Microbiology | June 18, 2009 | Volume: 47 | Issue: 8 | Pages: 2635-2638

10.1128/jcm.02170-08 | PMID 19535519 Get It

ABSTRACT A prototype, real-time reverse-transcription PCR assay, based on MultiCode-RTx technology, quantifying hepatitis C virus (HCV) RNA by targeting the HCV 3′ untranslated region demonstrated linearity over 7 logs, with a good correlation between the quantitative results of this assay and the results of two commercially available comparator assays for 466 clinical specimens comprising all six HCV genotypes.
Anomalous Quantitation Standard Growth Curves in a Laboratory-Developed Hepatitis C Virus (HCV) RNA Quantification Assay Using the TaqMan HCV Analyte-Specific Reagent
Germer, Jeffrey J., Kathrotiya, Jemee D., Bouse, Carrie F., Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | May 7, 2009 | Volume: 47 | Issue: 7 | Pages: 2317-2320

10.1128/jcm.00028-09 | PMID 19420174 Get It

ABSTRACT A retrospective examination of quantitation standard growth curves associated with 1,000 unique clinical serum specimens tested by a laboratory-developed TaqMan hepatitis C virus analyte-specific reagent-based assay revealed anomalous growth curves associated with 0.40% (95% confidence interval, 0.11% to 1.00%) of these specimens.