Citations

Mayo Clinic

Clear

43 citation(s) found for "O'Connor, Michael K".

Cerebral topography of rectal stimulation using single photon emission computed tomography
Bouras, Ernest P., O’Brien, Terence J. , Camilleri, Michael , O’Connor, Michael K. , Mullan, Brian P.

American Journal of Physiology-Gastrointestinal and Liver Physiology | December 24, 2017 | Volume: 277 | Issue: 3 | Pages: G687-G694

10.1152/ajpgi.1999.277.3.g687 | PMID 10484395 Get It

Central processing of visceral information in humans is incompletely understood. We aimed to demonstrate the feasibility of single photon emission computed tomography (SPECT) and to quantitate the changes in regional cerebral blood flow during rectal distension. Ten healthy volunteers underwent randomized sham and active rectal distensions on separate days, during which cerebral blood flow was assessed by intravenous technetium-99m ethyl cysteinate dimer (99mTc-ECD) SPECT. Three-dimensional coregistration of brain images was used to quantitate activation in four preselected cerebral foci and two control regions. Paired analysis compared blood flow during sham and active distensions. There was increased right anterior cingulate gyrus activity (6.5 ± 2.9%, P = 0.03) with active rectal distension. A 5.4 ± 2.4% reduction in blood flow in the superior parieto-occipital control region ( P = 0.04) suggested blood “redistribution” during stimulation. Marked variability in activation of the frontal cortex, thalamus/basal ganglia complex, and mesiotemporal lobe was noted. Thus rectal distension increases activity in the right anterior cingulate gyrus on average; other foci of cerebral activation are quite variable, suggesting a lack of specific cerebral projections during rectal stimulation.
Technical Note: Development of a combined molecular breast imaging/ultrasound system for diagnostic evaluation of MBI‐detected lesions
O’Connor, Michael K. , Morrow, Melissa M. , Conners, Amy Lynn , Hunt, Katie N. , Hruska, Carrie B. , Conners, Amy L, Tran, Thuy Thi Thu , Morrow, Melissa M

Medical Physics | December 10, 2016 | Volume: 44 | Issue: 2 | Pages: 451-459

10.1002/mp.12043 | PMID 28133745 Get It

PurposeThe purpose of this study was to perform a pilot evaluation of an integrated molecular breast imaging/ultrasound (MBI/US) system designed to enable, in real‐time, the registration of US to MBI and diagnostic evaluation of breast lesions detected on MBI.MethodsThe MBI/US system was constructed by modifying an existing dual‐head cadmium zinc telluride (CZT)‐based MBI gamma camera. The upper MBI detector head was replaced with a mesh panel, which allowed an ultrasound probe to access the breast. An optical tracking system was used to monitor the location of the ultrasound transducer, referenced to the MBI detector. The lesion depth at which ultrasound was targeted was estimated from analysis of previously acquired dual‐head MBI datasets. A software tool was developed to project the US field of view onto the current MBI image. Correlation of lesion location between both modalities with real‐time MBI/US scanning was confirmed in a breast phantom model and assessed in 12 patients with a breast lesion detected on MBI.ResultsCombined MBI/US scanning allowed for registration of lesions detected on US and MBI as validated in phantom experiments. In patient studies, successful registration was achieved in 8 of 12 (67%) patients, with complete registration achieved in seven and partial registration achieved in one patient. In 4 of 12 (37%) patients, lesion registration was not achieved, partially attributed to uncertainty in lesion depth estimates from MBI.ConclusionThe MBI/US system enabled successful registration of US to MBI in over half of patients studied in this pilot evaluation. Future studies are needed to determine if real‐time, registered US imaging of MBI‐detected lesions may obviate the need to proceed to more expensive procedures such as contrast‐enhanced breast MRI for diagnostic workup or biopsy of MBI findings.
Curative ex vivo liver-directed gene therapy in a pig model of hereditary tyrosinemia type 1
Mao, Shennen A. , Glorioso, Jaime , Elgilani, Faysal, Amiot, Bruce , Chen, Harvey , Rinaldo, Piero, Marler, Ronald J., Jiang, Huailei , DeGrado, Timothy R. , Suksanpaisan, Lukkana , O’Connor, Michael K. , Freeman, Brittany L., Ibrahim, Samar H. , Peng, Kah Whye, Grompe, Markus , Ikeda, Yasuhiro , Lillegard, Joseph B. , Russell, Stephen J. , Nyberg, Scott L. , Hickey, Raymond D, Marler, Ronald, O'Connor, Michael K, Hickey, Raymond , Harding, Cary O. , Ho, Chak‐Sum , Russell, Stephen J , Ibrahim, Samar H , Mao, Shennen A , Jiang, Huailei

Science Translational Medicine | July 27, 2016 | Volume: 8 | Issue: 349 | Pages: No page available

10.1126/scitranslmed.aaf3838 | PMID 27464750 Get It

Transplantation of gene-corrected autologous hepatocytes can cure metabolic disease in a preclinical pig model of hereditary tyrosinemia type 1.
Diagnostic Workup and Costs of a Single Supplemental Molecular Breast Imaging Screen of Mammographically Dense Breasts
Conners, Amy Lynn , Jones, Katie N., O’Connor, Michael K. , Moriarty, James P. , Rhodes, Deborah J. , Hruska, Carrie B. , Boughey, Judy C.

American Journal of Roentgenology | May 22, 2015 | Volume: 204 | Issue: 6 | Pages: 1345-1353

10.2214/ajr.14.13306 | PMID 26001247 Get It

JOURNAL CLUB: Molecular Breast Imaging at Reduced Radiation Dose for Supplemental Screening in Mammographically Dense Breasts
Rhodes, Deborah J. , Conners, Amy Lynn , Tortorelli, Cindy L., Maxwell, Robert W. , Jones, Katie N., Toledano, Alicia Y. , O’Connor, Michael K. , Hruska, Carrie B.

American Journal of Roentgenology | January 23, 2015 | Volume: 204 | Issue: 2 | Pages: 241-251

10.2214/ajr.14.13357 | PMID 25615744 Get It

Noninvasive 3‐dimensional imaging of liver regeneration in a mouse model of hereditary tyrosinemia type 1 using the sodium iodide symporter gene
Mao, Shennen A. , Amiot, Bruce , Suksanpaisan, Lukkana , Miller, Amber , Nace, Rebecca A., Glorioso, Jaime , O’Connor, Michael K. , Peng, Kah Whye, Russell, Stephen J. , Nyberg, Scott L. , Hickey, Raymond D, Hickey, Raymond , Ikeda, Yasuhiro , Russell, Stephen J , Mao, Shennen A

Liver Transplantation | December 9, 2014 | Volume: 21 | Issue: 4 | Pages: 442-453

10.1002/lt.24057 | PMID 25482651 Get It

Cell transplantation is a potential treatment for the many liver disorders that are currently only curable by organ transplantation. However, one of the major limitations of hepatocyte (HC) transplantation is an inability to monitor cells longitudinally after injection. We hypothesized that the thyroidal sodium iodide symporter (NIS) gene could be used to visualize transplanted HCs in a rodent model of inherited liver disease: hereditary tyrosinemia type 1. Wild‐type C57Bl/6J mouse HCs were transduced ex vivo with a lentiviral vector containing the mouse Slc5a5 (NIS) gene controlled by the thyroxine‐binding globulin promoter. NIS‐transduced cells could robustly concentrate radiolabeled iodine in vitro, with lentiviral transduction efficiencies greater than 80% achieved in the presence of dexamethasone. Next, NIS‐transduced HCs were transplanted into congenic fumarylacetoacetate hydrolase knockout mice, and this resulted in the prevention of liver failure. NIS‐transduced HCs were readily imaged in vivo by single‐photon emission computed tomography, and this demonstrated for the first time noninvasive 3‐dimensional imaging of regenerating tissue in individual animals over time. We also tested the efficacy of primary HC spheroids engrafted in the liver. With the NIS reporter, robust spheroid engraftment and survival could be detected longitudinally after direct parenchymal injection, and this thereby demonstrated a novel strategy for HC transplantation. This work is the first to demonstrate the efficacy of NIS imaging in the field of HC transplantation. We anticipate that NIS labeling will allow noninvasive and longitudinal identification of HCs and stem cells in future studies related to liver regeneration in small and large preclinical animal models. Liver Transpl 21:442–453, 2015. © 2015 AASLD.
Threshold Values for Preserved Viability With a Noninvasive Measurement of Collateral Blood Flow During Acute Myocardial Infarction Treated by Direct Coronary Angioplasty
Berger, Peter B. , O’Connor, Michael K. , Hodge, David O. , Christian, Timothy F. , Gibbons, Raymond J.

Circulation | June 12, 2012 | Volume: 100 | Issue: 24 | Pages: 2392-2395

10.1161/01.cir.100.24.2392 | PMID 10595949 Get It

Background —Quantitative measures of myocardial perfusion defect severity from acute 99m Tc-sestamibi tomographic images (nadir) have correlated closely with collateral and residual antegrade blood flow during acute myocardial infarction. The purpose of this study was to determine whether a viability threshold could be identified from this measure in patients with acute myocardial infarction treated in a homogeneous manner with successful reperfusion therapy. Methods and Results —The study group consisted of 61 patients with acute myocardial infarction with a risk area of >6% LV treated with primary angioplasty between 120 and 240 minutes after symptom onset. All patients were injected with 20 to 30 mCi of 99m Tc-sestamibi before primary angioplasty and imaged after the procedure. Acute myocardium at risk (MAR) and subsequent infarct size (IS) were quantified by a threshold program. Severity (nadir) from the acute image was the lowest ratio of minimal/maximum counts from 5 short-axis slices. Infarct location was anterior in 22 and inferior in 39 patients. MAR was 33±15% LV and IS was 13±15% LV: 23 patients had no infarction despite MAR similar to those with infarction. Receiver-operator characteristic curve analysis identified a nadir value of 0.26 as providing the best separation of patients with and without infarction (sensitivity, 74%; specificity, 74%). This nadir threshold varied by infarct location: anterior defect, 0.21; inferior defect, 0.31. The sensitivity and specificity for absent infarction for these values were anterior, 69% and 67%, and inferior, 88% and 84%, respectively. Conclusions —In a time frame in which the presence of residual blood flow is important, the severity of the acute 99m Tc-sestamibi defect can be used to predict whether infarction will develop despite successful reperfusion.
Temporal lobectomy outcome in older versus younger adults
Sirven, Joseph I , Malamut, Barbara L., O’Connor, Michael J., Sperling, Michael R. , Sperling, Michael R

Neurology | May 13, 2012 | Volume: 54 | Issue: 11 | Pages: 2166-2170

10.1212/wnl.54.11.2166 | PMID 10851387 Get It

Randomized, comparative study of interferon β-1a treatment regimens in MS
Panitch, Hillel, Francis, G., Chang, Peter , Coyle, Patricia K. , Ed, Monaghan, Li, D., Weinshenker, Brian G. , Goodin, Douglas S. , O’Connor, Paul , Weinshenker, Brian G

Neurology | May 13, 2012 | Volume: 59 | Issue: 10 | Pages: 1496-1506

10.1212/01.wnl.0000034080.43681.da | PMID 12451188 Get It

Evaluation of Molecular Breast Imaging in Women Undergoing Myocardial Perfusion Imaging with Tc-99m Sestamibi
Rhodes, Deborah J. , Collins, Douglas A. , Tortorelli, Cindy L., Askew, J. Wells , O’Connor, Michael K. , Hruska, Carrie B.

Journal of Women's Health | March 9, 2012 | Volume: 21 | Issue: 7 | Pages: 730-738

10.1089/jwh.2011.3267 | PMID 22404787 Get It