Citations

Mayo Clinic

Clear

237 citation(s) found for "Illés, Árpád".

Cystatin C Falsely Underestimated GFR in a Critically Ill Patient with a New Diagnosis of AIDS
Brown, Caitlin S. , Clain, Jeremy M., Frazee, Erin N. , Frazee, Erin N , Kashani, Kianoush

Case Reports in Nephrology | May 17, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-4

10.1155/2016/9349280 | PMID 27293926 Get It

Cystatin C has been suggested to be a more accurate glomerular filtration rate (GFR) surrogate than creatinine in patients with acquired immunodeficiency syndrome (AIDS) because it is unaffected by skeletal muscle mass and dietary influences. However, little is known about the utility of this marker for monitoring medications in the critically ill. We describe the case of a 64-year-old female with opportunistic infections associated with a new diagnosis of AIDS. During her course, she experienced neurologic, cardiac, and respiratory failure; yet her renal function remained preserved as indicated by an eGFR ≥ 120 mL/min and a urine output > 1 mL/kg/hr without diuresis. The patient was treated with nephrotoxic agents; therefore cystatin C was assessed to determine if cachexia was resulting in a falsely low serum creatinine. Cystatin C measured 1.50 mg/L which corresponded to an eGFR of 36 mL/min. Given the >60 mL/min discrepancy, serial 8-hour urine samples were collected and a GFR > 120 mL/min was confirmed. It is unclear why cystatin C was falsely elevated, but we hypothesize that it relates to the proinflammatory state with AIDS, opportunistic infections, and corticosteroids. More research is needed before routine use of cystatin C in this setting can be recommended.
Guidelines for the Appropriate Use of Bedside General and Cardiac Ultrasonography in the Evaluation of Critically Ill Patients—Part II: Cardiac Ultrasonography
Levitov, Alexander , Frankel, Heidi L., Blaivas, Michael , Su, Erik , Evans, David P. , Summerfield, Douglas T. , Slonim, Anthony D. , Breitkreutz, Raoul, McLaughlin, Matthew, Marik, Paul E. , Elbarbary, Mahmoud , Kirkpatrick, Andrew W. , Price, Susanna

Critical Care Medicine | May 17, 2016 | Volume: 44 | Issue: 6 | Pages: 1206-1227

10.1097/ccm.0000000000001847 | PMID 27182849 Get It

Objective: To establish evidence-based guidelines for the use of bedside cardiac ultrasound, echocardiography, in the ICU and equivalent care sites. Methods: Grading of Recommendations, Assessment, Development and Evaluation system was used to rank the “levels” of quality of evidence into high (A), moderate (B), or low (C) and to determine the “strength” of recommendations as either strong (strength class 1) or conditional/weak (strength class 2), thus generating six “grades” of recommendations (1A–1B–1C–2A–2B–2C). Grading of Recommendations, Assessment, Development and Evaluation was used for all questions with clinically relevant outcomes. RAND Appropriateness Method, incorporating the modified Delphi technique, was used in formulating recommendations related to terminology or definitions or in those based purely on expert consensus. The process was conducted by teleconference and electronic-based discussion, following clear rules for establishing consensus and agreement/disagreement. Individual panel members provided full disclosure and were judged to be free of any commercial bias. Results: Forty-five statements were considered. Among these statements, six did not achieve agreement based on RAND appropriateness method rules (majority of at least 70%). Fifteen statements were approved as conditional recommendations (strength class 2). The rest (24 statements) were approved as strong recommendations (strength class 1). Each recommendation was also linked to its level of quality of evidence and the required level of echo expertise of the intensivist. Key recommendations, listed by category, included the use of cardiac ultrasonography to assess preload responsiveness in mechanically ventilated (1B) patients, left ventricular (LV) systolic (1C) and diastolic (2C) function, acute cor pulmonale (ACP) (1C), pulmonary hypertension (1B), symptomatic pulmonary embolism (PE) (1C), right ventricular (RV) infarct (1C), the efficacy of fluid resuscitation (1C) and inotropic therapy (2C), presence of RV dysfunction (2C) in septic shock, the reason for cardiac arrest to assist in cardiopulmonary resuscitation (1B–2C depending on rhythm), status in acute coronary syndromes (ACS) (1C), the presence of pericardial effusion (1C), cardiac tamponade (1B), valvular dysfunction (1C), endocarditis in native (2C) or mechanical valves (1B), great vessel disease and injury (2C), penetrating chest trauma (1C) and for use of contrast (1B–2C depending on indication). Finally, several recommendations were made regarding the use of bedside cardiac ultrasound in pediatric patients ranging from 1B for preload responsiveness to no recommendation for RV dysfunction. Conclusions: There was strong agreement among a large cohort of international experts regarding several class 1 recommendations for the use of bedside cardiac ultrasound, echocardiography, in the ICU. Evidence-based recommendations regarding the appropriate use of this technology are a step toward improving patient outcomes in relevant patients and guiding appropriate integration of ultrasound into critical care practice.
Engaging Critically Ill Patients in Symptom Management: Thinking Outside the Box!
Chlan, Linda L.

American Journal of Critical Care | May 1, 2016 | Volume: 25 | Issue: 3 | Pages: 202-202

10.4037/ajcc2016671 Get It

Incidence of and Risk Factors For Post-Intubation Hypotension in the Critically Ill
Demirci, Onur , Diedrich, Daniel A. , Barbara, David W. , Sandefur, Benjamin J. , Trivedi, Sangita , McGarry, Sean D. , Smischney, Nathan J. , Kashyap, Rahul

Medical Science Monitor | April 12, 2016 | Volume: 22 | Issue: No issue available | Pages: 346-355

10.12659/msm.895919 | PMID 26831818 Get It

Tricuspid Annular Plane Systolic Excursion and Its Association with Mortality in Critically Ill Patients
Gajanana, Deepakraj, Rammohan, Harish Seetha, Alli, Oluseun , Romero‐Corral, Abel, Purushottam, Bhaskar, Ponamgi, Shiva , Figueredo, Vincent M. , Pressman, Gregg S.

Echocardiography | March 2, 2015 | Volume: 32 | Issue: 8 | Pages: 1222-1227

10.1111/echo.12926 | PMID 25728401 Get It

BackgroundTransient left ventricular dysfunction can occur under conditions of extreme emotional or physiological stress. There is little data on right ventricular function in such situations.MethodsOne hundred twenty patients admitted to an ICU with a noncardiac illness were studied. Those with documented coronary disease, ejection fraction <40%, sepsis, or intracranial hemorrhage were excluded. Echocardiograms were performed within 24 hours of admission. Tricuspid annular plane systolic excursion (TAPSE) was measured to assess right ventricular systolic function. Plasma catecholamines (norepinephrine, epinephrine, dopamine) were measured on admission. Clinical and demographic data were collected, along with data on ICU length of stay (LOS), hospital LOS, and in‐hospital and long‐term mortality. TAPSE was tested for correlation with adverse outcomes and length of stay.ResultsMean TAPSE for the group was 2.05 ± 0.66 cm. Based on area under the ROC curve analysis, TAPSE <2.4 cm was the best cutoff for predicting in‐hospital and long‐term mortality. There were 13 in‐hospital deaths, 12 in the group with TAPSE <2.4 cm and one among those with TAPSE ≥2.4 cm. On multivariate analysis, TAPSE <2.4 cm was a significant predictor of in‐hospital mortality (χ2 = 4.6, P = 0.03). When tested against hospital LOS, an inverse correlation was found (P = 0.04). No association was found between TAPSE and catecholamine levels.ConclusionsRight ventricular systolic function, as assessed by TAPSE, has important prognostic value in critically ill patients. Mean values were lower in patients who died in‐hospital versus those who survived to discharge. In addition, patients with TAPSE <2.4 cm had a longer hospital length of stay.
Ketamine and Propofol Combination (“Ketofol”) for Endotracheal Intubations in Critically Ill Patients: A Case Series
Hoskote, Sumedh S. , Moraes, Alice Gallo de , Gallo de Moraes, Alice, Racedo Africano, Carlos J, Reddy, Dereddi Raja S, Tedja, Rudy, Thakur, Lokendra , Pannu, Jasleen K, Hassebroek, Elizabeth C, Smischney, Nathan J. , Gallo de Moraes, Alice

American Journal of Case Reports | February 13, 2015 | Volume: 16 | Issue: No issue available | Pages: 81-86

10.12659/ajcr.892424 | PMID 25676819 Get It

The conundrum of underfeeding vs overfeeding neurocritically ill patients
Suárez, José I. , Vizzini, Angela, Freeman, William D. , Freeman, William D

Neurology | January 17, 2015 | Volume: 84 | Issue: 7 | Pages: 639-640

10.1212/wnl.0000000000001272 | PMID 25596502 Get It

Overestimation of Glomerular Filtration Rate Among Critically Ill Adults With Hospital-Acquired Oligoanuric Acute Kidney Injury
Frazee, Erin N., Personett, Heather A. , Wood‐Wentz, Christina M. , Herasevich, Vitaly , Frazee, Erin N., Lieske, John C. , Kashani, Kianoush , Herasevich, Vitaly

Journal of Pharmacy Practice | October 18, 2014 | Volume: 29 | Issue: 2 | Pages: 125-131

10.1177/0897190014549841 | PMID 25326198 Get It

Background: Medication use in the intensive care unit (ICU) depends on creatinine-based glomerular filtration rate (GFR) estimates. Urine output deterioration may precede the creatinine rise resulting in delayed recognition of GFR reductions. Our objective was to quantify the disparity between estimated GFR (eGFR) and true GFR in ICU patients with hospital-acquired oligoanuric acute kidney injury (hAKI). Methods: This single-center cohort study examined adults who met the Acute Kidney Injury Network stage III urine output criterion ≥48 hours after ICU admission. True GFR was ≤15 mL/min/1.73 m 2 , and eGFR was described by 6 different creatinine-based equations. True GFR and eGFR were compared on the day of hAKI diagnosis and followed for 4 days using multivariable linear regression with generalized estimating equations, adjusting for day and method. Results: Of the 691 patients screened, we enrolled 61 patients. After adjustment for multiple comparisons and day, there were significant differences in eGFR between the estimation methods and true GFR ( P < .001). After day adjustment, eGFR overestimated true GFR by 17 to 50 mL/min/1.73 m 2 and overestimation persisted through the fourth day of hAKI ( P ≤ .001). Conclusion: Creatinine-based equations overestimated GFR in ICU patients with hAKI. This study highlights a population at risk of medication misadventures in whom systems optimization should be considered.
Retrospective Evaluation of the Accuracy of Roche AccuChek Inform and Nova StatStrip Glucose Meters when Used on Critically Ill Patients
Karon, Brad S. , Blanshan, Chanse T., Deobald, Gayle R., Wockenfus, Amy M.

Diabetes Technology & Therapeutics | August 5, 2014 | Volume: 16 | Issue: 12 | Pages: 828-832

10.1089/dia.2014.0074 | PMID 25093919 Get It

Background: More stringent accuracy guidelines for hospital-use glucose meters have recently been published, but it remains unclear whether glucose meters can meet these accuracy guidelines when measurement is performed on critically ill patients with fresh whole blood samples. Materials and Methods: We performed a retrospective evaluation of a conventional (Roche Diagnostics [Indianapolis, IN] AccuChek ® Inform) and a newer-generation (Nova Biomedical [Waltham, MA] StatStrip ® ) glucose system by comparing paired (drawn within 5 min of each other) whole blood glucose meter and laboratory serum glucose values obtained from intensive care unit (ICU) patients. We also performed a prospective evaluation of the accuracy of the Nova StatStrip. Results: The median (interquartile range) bias between Roche AccuChek Inform and serum laboratory glucose measurements was 11 (6–18) mg/dL, compared with a median bias between the Nova StatStrip and serum glucose measurements of 1 (−5 to 5) mg/dL. StatStrip met International Organization for Standardization 15197 and Clinical and Laboratory Standards Institute (CLSI) POCT12-A3 accuracy guidelines using both retrospective and prospective datasets. Conclusions: The newer-generation (StatStrip) glucose meter met more stringent CLSI POCT12-A3 accuracy criteria because of reduced bias compared with the previous-generation device. Reduced glucose meter bias led to fewer insulin dosing discrepancies when the insulin dose determined from serum glucose was compared with that determined from the glucose meter value using the institutional glycemic control protocol.