Citations

Mayo Clinic

Clear

2128 citation(s) found for "Ju, Christine".

P4‐300: Gene expression profiling to identify microvascular changes in Alzheimer's disease mouse models
Pereson, Sandra, Vandewoestyne, Mado, Broeck, Bianca Van, Cuijt, Ivy , Peeters, E.F.H.I., Ceuterick, Chantal, McGowan, Eileen , Jucker, Mathias , Broeckhoven, Christine Van , Deforce, Dieter L. D. , Kumar‐Singh, Samir

Alzheimer's & Dementia | July 24, 2008 | Volume: 4 | Issue: 4S_Part_23 | Pages: No page available

10.1016/j.jalz.2008.05.2369 Get It

P3‐108: Subjective memory complaints in the healthy elderly
Belden, Christine M. , Connor, Donald J., Adler, Charles, Sabbagh, Marwan N.

Alzheimer's & Dementia | July 24, 2008 | Volume: 4 | Issue: 4S_Part_17 | Pages: No page available

10.1016/j.jalz.2008.05.1673 Get It

Phase I-II Trial of Bortezomib Plus Oral Cyclophosphamide and Prednisone in Relapsed and Refractory Multiple Myeloma
Reece, Donna , Rodriguez, Giovanni Piza, Chen, Christine , Trudel, Suzanne , Kukreti, Vishal , Pantoja, Mariela, Xu, Wei , Stewart, A. Keith, Mıkhael, Joseph

Journal of Clinical Oncology | July 21, 2008 | Volume: 26 | Issue: 29 | Pages: 4777-4783

10.1200/jco.2007.14.2372 | PMID 18645194 Get It

Purpose The combination of oral weekly cyclophosphamide and alternate day prednisone is a convenient regimen for relapsed/refractory multiple myeloma (MM), and we sought to improve its efficacy by adding bortezomib, a proteasome inhibitor with proven antimyeloma activity. Patients and Methods We conducted a phase I-II trial evaluating six dose levels to define the maximum tolerated dose (MTD) of this combination in relapsed/refractory MM. An additional 10 patients were evaluated at the highest dose level reached. Results Thirty-seven patients were treated on this study. The MTD was not defined. Both of the highest dose levels of bortezomib tested (1.3 mg/m 2 on days 1, 4, 8, and 11 and 1.5 mg/m 2 on days 1, 8, and 15, each on a 28-day cycle) could be safely given with cyclophosphamide 300 mg/m 2 per week and prednisone. At these dose levels, the overall response rate was 95% (complete responses [CR] plus partial response plus minimal response), with CR observed in more than 50% of patients. The weekly bortezomib regimen resulted in fewer instances of grade 3 thrombocytopenia and grade 1 to 2 peripheral neuropathy; the 1-year progression-free and overall survival probabilities with this dose level were 83% (95% CI, 73% to 96%) and 100%, respectively. Conclusion Weekly bortezomib 1.5 mg/m 2 plus oral cyclophosphamide and prednisone produces an unprecedented response rate and encouraging 1-year survival in relapsed/refractory patients with MM. Further evaluation of this promising regimen is warranted both in relapsed and newly diagnosed disease.
Multifocal Renal Cell Carcinoma: Clinicopathologic Features and Outcomes for Tumors ≤
Crispen, Paul L. , Lohse, Christine M. , Blute, Michael L.

Advances in Urology | July 16, 2008 | Volume: 2008 | Issue: No issue available | Pages: 1-7

10.1155/2008/518091 | PMID 18645615 Get It

A significant increase in the incidental detection of small renal tumors has been observed with the routine use of cross-sectional abdominal imaging. However, the proportion of small renal tumors associated with multifocal RCC has yet to be established. Here then, we report our experience with the treatment of multifocal RCC in which the primary tumor was ≤4 cm. In our series of 1113 RCC patients, 5.4% (60/1113) had multifocal disease at the time of nephrectomy. Discordant histology was present in 17% (10/60) of patients with multifocal RCC. Nephron sparing surgery was utilized more frequently in patients with solitary tumors. Overall, cancer-specific, and distant metastasis-free survival appeared to be similar between multifocal and solitary tumors. These findings are consistent with previous series which evaluated multifocal RCC with tumors >4 cm. With the known incidence of multifocality RCC, careful inspection of the entire renal unit should be performed when performing nephron sparing surgery.
A collaborative effort to comply with USP chapter 797 for compounding sterile preparations for investigational use
Formea, Christine M. , Weiss, William T., McCluskey, Susan V

American Journal of Health-System Pharmacy | June 23, 2008 | Volume: 65 | Issue: 13 | Pages: 1266-1269

10.2146/ajhp070497 | PMID 18574018 Get It

In Reply
Leibovich, Bradley C. , Sheinin, Yuri, Lohse, Christine M. , Thompson, R. Houston, Cheville, John C. , Závada, J, Kwon, Eugene D.

Journal of Clinical Oncology | June 18, 2008 | Volume: 26 | Issue: 18 | Pages: 3107-3109

10.1200/jco.2008.16.2164 Get It

Computed tomography imaging of the paranasal sinuses: Direct versus reformatted coronal images
Pletcher, Steven D. , Hoxworth, Joseph M. , Goldberg, Andrew N. , Murr, Andrew H. , Glastonbury, Christine M. , Hoxworth, Joseph M

Otolaryngology–Head and Neck Surgery | June 4, 2008 | Volume: 138 | Issue: 6 | Pages: 710-714

10.1016/j.otohns.2008.03.001 | PMID 18503840 Get It

ObjectiveTo evaluate the image quality of coronal reformatted CT images compared with direct coronal CT images.Study DesignCross‐sectional.Subjects and MethodsPatients who underwent paranasal sinus CT scans using both direct coronal images (DC) and axially acquired images with coronal reconstructions (CR) were consecutively enrolled. Two reconstruction groups were evaluated: group CR1 with 1‐mm axial collimation and group CR2 with 0.625‐mm axial collimation. Scans were presented in a randomized, blinded fashion to two sinus surgeons and a neuroradiologist.ResultsWhen compared with CR1, DC images had higher image quality for each of five key anatomic landmarks (P <. 0001). DC images were more likely to be adequate preoperative imaging (P <. 0001). When compared with CR2, improved DC image quality was noted in the majority of key anatomic landmarks. No difference was noted in the “adequacy rating” between the DC and CR2 (0.625 mm) protocols.ConclusionThe 0.625‐mm reformatted images were judged to be adequate preoperative imaging. The additional information provided by multiple‐image planes make reformatted 0.625‐mm axial images an acceptable approach.
Surgical Resection of Isolated Retroperitoneal Lymph Node Recurrence of Renal Cell Carcinoma Following Nephrectomy
Boorjian, Stephen A. , Crispen, Paul L. , Lohse, Christine M. , Leibovich, Bradley C. , Blute, Michael L.

Journal of Urology | May 16, 2008 | Volume: 180 | Issue: 1 | Pages: 99-103

10.1016/j.juro.2008.03.025 | PMID 18485415 Get It

Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention
Henz, Benhur Davi , Johnson, Susan B., Bunch, T. Jared , O'BRIEN, CHRISTINE J., Hodge, David O. , Altman, Andres, Govari, Assaf , Packer, Douglas L. , Okumura, Yasuo

Circulation: Arrhythmia and Electrophysiology | April 30, 2008 | Volume: 1 | Issue: 2 | Pages: 110-119

10.1161/circep.108.769935 | PMID 19808401 Get It

Background— Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. Methods and Results— Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1�1.1 mm for atrial and 2.4�1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3�1.6 mm; ventricles: 4.8�2.0 mm; P< 0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1�1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98�24 cm 3 versus 109�25 cm 3 , P< 0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. Conclusions— These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.
B7-H1 Expression in Wilms Tumor: Correlation With Tumor Biology and Disease Recurrence
Routh, Jonathan C. , Ashley, Richard , Sebo, Thomas J., Lohse, Christine M. , Husmann, Douglas A. , Kramer, Stephen A., Kwon, Eugene D., Routh, Jonathan C

Journal of Urology | March 21, 2008 | Volume: 179 | Issue: 5 | Pages: 1954-1960

10.1016/j.juro.2008.01.056 | PMID 18355839 Get It