Citations

Mayo Clinic

Clear

19 citation(s) found for "Ruiter, Godard C W de".

Extreme subparaneurial ganglion cysts. Part 2: The geyser theory as a mechanistic explanation for crossover
Ruiter, Godard C. W. de , Howe, B. Matthew, Son, Byung-chul , Amrami, Kimberly K. , Spinner, Robert J. , de Ruiter, Godard C W, Reina, Miguel Ángel , Sala‐Blanch, Xavier

Journal of Neurosurgery | July 4, 2025 | Volume: 143 | Issue: 6 | Pages: 1653-1666

10.3171/2025.2.jns242816 | PMID 40614278 Get It

OBJECTIVE Extreme subparaneurial ganglion cysts are poorly understood. In Part 1, the authors demonstrated that patterns of distribution in the subparaneurial space are consistent with the principles of the articular theory for intraneural ganglion cysts (INGCs). How a cyst transfers from the subepineurial to the subparaneurial compartment remains to be determined. In this part, the authors provide evidence supporting that cyst transfer occurs at the sciatic nerve bifurcation based on MRI and histological analysis, and introduce the geyser theory as an explanation for the redistribution of cysts. METHODS The authors analyze MR images obtained in patients with extreme subparaneurial cysts as well as newly identified cases of nearly extreme subparaneurial cysts (i.e., cysts visible in the subparaneurial compartment but not to the extreme degree as defined in Part 1) for potential crossover sites. They also analyze histological sections from 10 cadavers around the sciatic nerve bifurcation for the presence of openings in the epineurium and paraneurium. RESULTS MRI studies performed in 8 patients in Part 1 and 8 newly identified examples with nearly extreme subparaneurial INGCs showed evidence to support communication between different compartments at the sciatic nerve bifurcation (subepineurial-to-subparaneurial and subparaneurial-to-neighboring soft tissues). Openings in the epineurium of the common peroneal and tibial nerves at the sciatic nerve bifurcation were consistently found in all 10 cadaver specimens, as were openings in the paraneurium. CONCLUSIONS The authors expand on the evidence to support cyst redistribution at the sciatic nerve bifurcation for INGCs in the knee region. They put forth a logical explanation for the development of a spectrum of extreme INGCs (ranging from a faint amount of cyst around the epineurium [wedding ring sign] to extreme subparaneurial INGCs [owl eyes]) based on principles seen in a geyser. The authors believe that radiological occurrence of crossover can be explained by the presence of fenestrations in both the epineurium and paraneurium at the sciatic nerve bifurcation, allowing cyst crossover in two steps: from the subepineurial to the subparaneurial space ("cross") and between a shared subparaneurial space of different nerves ("over"). Finally, the frequent occurrence of extraneural rupture ("cross-out") is due to cyst transfer into the soft tissue compartment via an opening in the outermost circumneurial layer.
Tibial intraneural ganglion cysts arising from the tibiofemoral joint: illustrative cases
Lenartowicz, Karina A. , Wu, Kitty Y. , Amrami, Kimberly K. , Ruiter, Godard C. W. de , Desy, Nicholas M. , Spinner, Robert J.

Journal of Neurosurgery: Case Lessons | September 4, 2023 | Volume: 6 | Issue: 10 | Pages: No page available

10.3171/case23314 | PMID 37728275 Get It

BACKGROUND Intraneural cysts involving the tibial nerve in the knee region (popliteal fossa) are rare. According to the articular (synovial) theory, which posits a joint origin for this pathology, these cysts originate from either the superior tibiofibular joint (STFJ) or the tibiofemoral (knee) joint. As tibial intraneural cysts arising from the tibiofemoral joint remain poorly understood, the authors present 2 illustrative cases and a review of the world’s literature on all tibial intraneural ganglion cysts in the knee region. OBSERVATIONS Fourteen cases of tibial intraneural ganglion cysts arising from the tibiofemoral joint were identified in the literature. Different articular branch patterns were demonstrated, which could be explained by the varied, rich articular branch innervation at the knee. Favorable outcomes were observed in cases in which the articular branch had been disconnected and the cyst drained and were comparable to the outcomes seen in tibial intraneural ganglion cysts with an STFJ origin. LESSONS Tibial intraneural cysts in the knee region can be subdivided by their joint of origin: the STFJ or the tibiofemoral joint. Those arising from the tibiofemoral joint originate from different areas of the joint and propagate in predictable patterns, with favorable outcomes following surgical intervention when the joint connection is identified and treated. The origin of tibial intraneural cysts from the tibiofemoral joint are more complex than those originating from the STFJ but seem to have similar propagation patterns and outcomes.
Innervation of the anconeus epitrochlearis muscle: MRI and cadaveric studies
Collin, Peter G., Ishak, Basem , Iwanaga, Joe , Amrami, Kimberly K. , Ringler, Michael D. , Ruiter, Godard C. W. de , Spinner, Robert J. , Tubbs, R. Shane , Tubbs, R Shane , Iwanaga, Joe , Grewal, Sanjeet S.

Clinical Anatomy | September 29, 2018 | Volume: 32 | Issue: 2 | Pages: 218-223

10.1002/ca.23285 | PMID 30267439 Get It

Ulnar neuropathy at the cubital tunnel is common. However, a rare form of ulnar neuropathy here is due to compression from an accessory muscle, the anconeus epitrochlearis. Reports in the literature regarding the details of this muscle's innervation are vague, so the aim of the present study was to characterize this anatomy more clearly. This was a combined review of magnetic resonance imaging (MRI) from patients with an anconeus epitrochlearis and ulnar neuropathy and cadaveric dissections to characterize the innervation of this variant muscle. A review of 11 patients and three reports of ulnar neuropathy and an anconeus epitrochlearis in the literature revealed no MRI changes consistent with acute denervation of this muscle. However, in two cases, there were signs of chronic denervation of the muscle. Dissection of five cadavers revealed that the nerve supply to the anconeus epitrochlearis originated proximal to the medial epicondyle, traveled parallel to the ulnar nerve, terminated on the deep aspect of this muscle, and had a mean length of 60 mm. This clinicoanatomical study provides evidence that the innervation of the anconeus epitrochlearis is proximal to the muscle and on its deep aspect. Clin. Anat. 32:218–223, 2019. © 2018 Wiley Periodicals, Inc.
The subparaneurial compartment: A new concept in the clinicoanatomic classification of peripheral nerve lesions
Prasad, Nikhil K. , Capek, Stepan , Ruiter, Godard C. W. de , Amrami, Kimberly K. , Spinner, Robert J.

Clinical Anatomy | July 2, 2015 | Volume: 28 | Issue: 7 | Pages: 925-930

10.1002/ca.22589 | PMID 26133748 Get It

Based on our experience in treating peripheral non‐neural sheath derived pathology, we have identified a novel pattern of lesion progression along the anatomic course of nerves. This report highlights the existence of a subparaneurial compartment around peripheral nerves. We first applied an anatomic framework to review MR images and intraoperative photographs of patients treated by the senior author in the last 10 years. After identifying a pattern that was consistent with subparaneurial lesion progression, we searched for other examples of cases that might exhibit this pattern. Four examples of subparaneurial pathology were identified, a hemangioma of the ulnar nerve, a ganglion cyst of the common fibular nerve, a lymphoma of the sciatic nerve and a lipoma of the ulnar nerve. All four patients were operated on and had intraoperative photographs; three had high resolution MR imaging. This report highlights the existence of pathology contained within a subparaneurial compartment, outside of the epineurium, that follows the course of the nerve and surrounds it circumferentially. The subparaneurial localization of peripheral nerve lesions has hitherto received little attention. Identification of this new pattern on preoperative MRI may have implications for surgical management. Clin. Anat. 28:925–930, 2015. © 2015 Wiley Periodicals, Inc.
Molecularly Engineered Biodegradable Polymer Networks with a Wide Range of Stiffness for Bone and Peripheral Nerve Regeneration
Wang, Shanfeng , Ruiter, Godard C. W. de , Spinner, Robert J. , Windebank, Anthony J. , Yaszemski, Michael J. , Lu, Lichun , Kempen, Diederik H.R. , Cai, Lei

Advanced Functional Materials | March 24, 2015 | Volume: 25 | Issue: 18 | Pages: 2715-2724

10.1002/adfm.201500105 Get It

To satisfy different mechanical requirements in hard and soft tissue replacements, a series of biodegradable and crosslinkable copolymers of poly(propylene fumarate)‐co‐polycaprolactone (PPF‐co‐PCL) are synthesized and employed to fabricate 2D disks and 3D scaffolds via photocrosslinking. Thermal properties such as the glass transition temperature (Tg) and melting temperature (Tm) of the PPF‐co‐PCL networks can be controlled efficiently by varying the PCL composition (φPCL). As a result, their mechanical properties vary significantly from hard and stiff materials to soft and flexible ones with increasing φPCL, making them attractive candidate materials for bone and peripheral nerve regeneration, respectively. Several PPF‐co‐PCL formulations are selected to perform in vitro cell studies using mouse pre‐osteoblastic MC3T3‐E1, rat Schwann cell precursor line (SPL201), and pheochromocytoma (PC12) cells, and in vivo animal testing in the rat femur bone defect model and in the rat sciatic nerve transection model. The formation of new bone in the porous bone scaffolds with a low φPCL and guided axon growth through the nerve conduits with a higher φPCL suggest that crosslinked PPF‐co‐PCLs have appropriate compatibility and functionality. Furthermore, the role of surface stiffness in modulating cellular behavior and functions is verified on the crosslinked PPF‐co‐PCL surfaces without any pretreatments.
Misdirection and guidance of regenerating axons after experimental nerve injury and repair
Ruiter, Godard C. W. de , Spinner, Robert J. , Verhaagen, Joost , Malessy, Martijn J. A.

Journal of Neurosurgery | October 11, 2013 | Volume: 120 | Issue: 2 | Pages: 493-501

10.3171/2013.8.jns122300 | PMID 24116727 Get It

Misdirection of regenerating axons is one of the factors that can explain the limited results often found after nerve injury and repair. In the repair of mixed nerves innervating different distal targets (skin and muscle), misdirection may, for example, lead to motor axons projecting toward skin, and vice versa—that is, sensory axons projecting toward muscle. In the repair of motor nerves innervating different distal targets, misdirection may result in reinnervation of the wrong target muscle, which might function antagonistically. In sensory nerve repair, misdirection might give an increased perceptual territory. After median nerve repair, for example, this might lead to a dysfunctional hand. Different factors may be involved in the misdirection of regenerating axons, and there may be various mechanisms that can later correct for misdirection. In this review the authors discuss these different factors and mechanisms that act along the pathway of the regenerating axon. The authors review recently developed evaluation methods that can be used to investigate the accuracy of regeneration after nerve injury and repair (including the use of transgenic fluorescent mice, retrograde tracing techniques, and motion analysis). In addition, the authors discuss new strategies that can improve in vivo guidance of regenerating axons (including physical guidance with multichannel nerve tubes and biological guidance accomplished using gene therapy).
Axon Regeneration through Scaffold into Distal Spinal Cord after Transection
Chen, Bing Kun, Ruiter, Godard C. W. de , Spinner, Robert J. , Yaszemski, Michael J. , Currier, Bradford L. , Windebank, Anthony J. , Knight, Andrew Michael

Journal of Neurotrauma | June 23, 2009 | Volume: 26 | Issue: 10 | Pages: 1759-1771

10.1089/neu.2008.0610 Get It

Designing ideal conduits for peripheral nerve repair
Ruiter, Godard C. W. de , Yaszemski, Michael J. , Windebank, Anthony J. , Spinner, Robert J. , Malessy, Martijn J. A.

Neurosurgical Focus | January 30, 2009 | Volume: 26 | Issue: 2 | Pages: E5

10.3171/foc.2009.26.2.e5 | PMID 19435445 Get It

Nerve tubes, guides, or conduits are a promising alternative for autologous nerve graft repair. The first biodegradable empty single lumen or hollow nerve tubes are currently available for clinical use and are being used mostly in the repair of small-diameter nerves with nerve defects of < 3 cm. These nerve tubes are made of different biomaterials using various fabrication techniques. As a result these tubes also differ in physical properties. In addition, several modifications to the common hollow nerve tube (for example, the addition of Schwann cells, growth factors, and internal frameworks) are being investigated that may increase the gap that can be bridged. This combination of chemical, physical, and biological factors has made the design of a nerve conduit into a complex process that demands close collaboration of bioengineers, neuroscientists, and peripheral nerve surgeons. In this article the authors discuss the different steps that are involved in the process of the design of an ideal nerve conduit for peripheral nerve repair.
ACCURACY OF MOTOR AXON REGENERATION ACROSS AUTOGRAFT, SINGLE-LUMEN, AND MULTICHANNEL POLY(LACTIC-CO-GLYCOLIC ACID) NERVE TUBES
Ruiter, Godard C. de, Spinner, Robert J. , Moore, Michael J. , Sorenson, Eric J. , Currier, Bradford L. , Yaszemski, Michael J. , Windebank, Anthony J. , Malessy, Martijn J. A.

Neurosurgery | August 26, 2008 | Volume: 63 | Issue: 1 | Pages: 144-155

10.1227/01.neu.0000335081.47352.78 | PMID 18728579 Get It