Citations

Mayo Clinic

Clear

28 citation(s) found for "J, Park Soon".

Coronary Artery Bypass Grafting Versus Drug-Eluting Stents in Patients with End-Stage Renal Disease
Shah, Ishan K., Lim, Ju Yong , Erwin, Patricia J., Park, Soon J., Deo, Salil V. , Dunlay, Shannon M. , Dillon, John

Journal of Cardiac Surgery | January 22, 2014 | Volume: 29 | Issue: 2 | Pages: 163-169

10.1111/jocs.12296 | PMID 24447133 Get It

Cardiovascular Implantable Electronic Device Infections in Left Ventricular Assist Device Recipients
Riaz, Talha , Nienaber, Juhsien J. C., Walker, Randall C., Park, Soon J., Sohail, M. Rizwan , Baddour, Larry M. , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | September 2, 2013 | Volume: 37 | Issue: 2 | Pages: 225-230

10.1111/pace.12240 | PMID 23998684 Get It

BackgroundMost patients with left ventricular assist devices (LVADs) have concomitant cardiovascular implantable electronic devices (CIEDs). However, clinical presentation and outcome of CIED infection in the setting of LVAD has not been previously described.MethodsWe retrospectively reviewed 247 patients who underwent LVAD implantation at Mayo Clinic campuses in Minnesota, Arizona, and Florida, from January 2005 to December 2011. Demographic and clinical data of patients who met criteria for CIED infection were extracted.ResultsOf 247 patients with LVADs, 215 (87%) had CIED at the time of LVAD implantation and six (2.8%) subsequently developed CIED infections. Three patients developed CIED lead‐related endocarditis and the other three had pocket infection. All three instances of CIED pocket infection were preceded by device generator exchange, whereas all three patients with CIED lead‐related endocarditis had prior LVAD‐related infections. Causative pathogens included Pseudomonas aeruginos (1), coagulase‐negative staphylococci (2), methicillin‐resistant Staphylococcus aureus (1), a gram‐positive bacillus (1), and culture negative (2). All patients underwent complete CIED removal along with antimicrobial therapy. The three patients with CIED lead‐related endocarditis and prior LVAD infections received chronic suppressive antibiotic therapy, and one patient had LVAD exchange. All but one remained alive at the last follow‐up with a median duration of 15 months (7–46 months) from the time of CIED infection.ConclusionPatients who are receiving LVAD therapy and develop CIED infection should be managed with complete CIED removal. Chronic suppressive antibiotic therapy is warranted in cases that have concomitant LVAD infection.
Repair of Acute Inferior Wall Myocardial Infarction-Related Basal Ventricular Septal Defect: Transatrial versus Transventricular Approach
Sharma, Vikas , Greason, Kevin L. , Schaff, Hartzell V. , Burkhart, Harold M. , Park, Soon J., Suri, Rakesh M. , Nkomo, Vuyisile T. , Dearani, Joseph A. , Schaff, Hartzell

Journal of Cardiac Surgery | July 22, 2013 | Volume: 28 | Issue: 5 | Pages: 475-480

10.1111/jocs.12156 | PMID 23870081 Get It

Real‐Time 3‐Dimensional Dynamics of Functional Mitral Regurgitation: A Prospective Quantitative and Mechanistic Study
Topilsky, Yan , Vaturi, Ori, Watanabe, Nozomi , Bichara, Valentina M., Mankad, Sunil , Park, Soon, Capps, Mary Ann, Suri, Rakesh M. , Pislaru, Sorin V. , Maalouf, Joseph F., Yoshida, Kiyoshi , Enriquez‐Sarano, Maurice , Nkomo, Vuyisile T. , Michelena, Héctor I. , Tourneau, Thierry Le , Sabbah, Michael S. , Enriquez-Sarano, Maurice , Topilsky, Yan

Journal of the American Heart Association | June 1, 2013 | Volume: 2 | Issue: 3 | Pages: No page available

10.1161/jaha.113.000039 | PMID 23727698 Get It

Background Three‐dimensional transthoracic echocardiography (3D‐ TTE ) with dedicated software permits quantification of mitral annulus dynamics and papillary muscle motion throughout the cardiac cycle. Methods and Results Mitral apparatus 3D‐ TTE was acquired in controls (n=42), patients with left ventricle dysfunction and functional mitral regurgitation ( LVD ‐ FMR ; n=43) or without FMR ( LVD ‐no MR , n=35). Annulus in both normal and LVD ‐no MR subjects displayed saddle shape accentuation in early‐systole (ratio of height to intercommissural diameter, 10.6±3.7 to 13.5±4.0 in normal and 9.1±4.3 to 12.6±3.6 in LVD ‐no MR ; P <0.001 for diastole to early‐systole motion, P = NS between those groups). In contrast, saddle shape was unchanged from diastole in FMR patients (10.0±6.4 to 8.0±5.2; P = NS , P <0.05 compared to both other groups). Papillary tips moved symmetrically towards to the midanterior annulus in control and LVD ‐no MR subjects, maintaining constant ratio of the distances between both tips to midannulus (Pt AR ) throughout systole. In LVD ‐ FMR patients midsystolic posterior papillary tip to anterior annulus distance was increased, resulting in higher Pt AR ( P =0.05 compared to both other groups). Mechanisms of early‐ and midsystolic FMR differed between different etiologies of LV dysfunction. In patients with anterior MI and global dysfunction annular function and dilatation were the dominant parameters, while papillary muscle motion was the predominant determinant of FMR in patients with inferior MI . Conclusions Inadequate early‐systolic annular contraction and saddle‐shape accentuation in patients with impaired LV contribute to early–mitral incompetency. Asymmetric papillary tip movement towards the midanterior annulus is a major determinant of mid‐ and late‐systolic functional mitral regurgitation.
Dual Anti-platelet Therapy After Coronary Artery Bypass Grafting: Is There Any Benefit? A Systematic Review and Meta-Analysis
Shah, Ishan K., Altarabsheh, Salah E. , Erwin, Patricia J., Boilson, Barry A. , Park, Soon J., Joyce, Lyle D., Deo, Salil V. , Dunlay, Shannon M. , Altarabsheh, Salah

Journal of Cardiac Surgery | March 15, 2013 | Volume: 28 | Issue: 2 | Pages: 109-116

10.1111/jocs.12074 | PMID 23488578 Get It

Multiple Arterial Grafts Improve Late Survival of Patients Undergoing Coronary Artery Bypass Graft Surgery
Locker, Chaim, Schaff, Hartzell V. , Joyce, Lyle D., Park, Soon J., Burkhart, Harold M. , Suri, Rakesh M. , Greason, Kevin L. , Stulak, John M., Daly, Richard C. , Li, Zhuo , Dearani, Joseph A. , Li, Zhuo Ya , Schaff, Hartzell

Circulation | July 19, 2012 | Volume: 126 | Issue: 9 | Pages: 1023-1030

10.1161/circulationaha.111.084624 | PMID 22811577 Get It

Background— Use of the left internal mammary artery (LIMA) in multivessel coronary artery disease improves survival after coronary artery bypass graft surgery; however, the survival benefit of multiple arterial (MultArt) grafts is debated. Methods and Results— We reviewed 8622 Mayo Clinic patients who had isolated primary coronary artery bypass graft surgery for multivessel coronary artery disease from 1993 to 2009. Patients were stratified by number of arterial grafts into the LIMA plus saphenous veins (LIMA/SV) group (n=7435) or the MultArt group (n=1187). Propensity score analysis matched 1153 patients. Operative mortality was 0.8% (n=10) in the MultArt and 2.1% (n=154) in the LIMA/SV ( P =0.005) group, which was not statistically different ( P =0.996) in multivariate analysis or the propensity-matched analysis ( P =0.818). Late survival was greater for MultArt versus LIMA/SV (10- and 15-year survival rates were 84% and 71% versus 61% and 36%, respectively [ P <0.001], in unmatched groups and 83% and 70% versus 80% and 60%, respectively [ P =0.0025], in matched groups). MultArt subgroups with bilateral internal mammary artery/SV (n=589) and bilateral internal mammary artery only (n=271) had improved 15-year survival (86% and 76%; 82% and 75% at 10 and 15 years [ P <0.001]), and patients with bilateral internal mammary artery/radial artery (n=147) and LIMA/radial artery (n=169) had greater 10-year survival (84% and 78%; P <0.001) versus LIMA/SV. In multivariate analysis, MultArt grafts remained a strong independent predictor of survival (hazard ratio, 0.79; 95% confidence interval, 0.66–0.94; P =0.007). Conclusions— In patients undergoing isolated coronary artery bypass graft surgery with LIMA to left anterior descending artery, arterial grafting of the non–left anterior descending vessels conferred a survival advantage at 15 years compared with SV grafting. It is still unproven whether these results apply to higher-risk subgroups of patients.
Iatrogenic Aortic Dissection … or Intramural Hematoma?
Welch, Terrence D., Foley, Thomas A. , Barsness, Gregory W. , Spittell, Peter C., Tilbury, R. Thomas, Enriquez‐Sarano, Maurice , Evangelista, Artur , Park, Soon J., Michelena, Héctor I. , Enriquez-Sarano, Maurice

Circulation | March 6, 2012 | Volume: 125 | Issue: 9 | Pages: No page available

10.1161/circulationaha.111.056937 | PMID 22392868 Get It

Outcomes in Advanced Heart Failure Patients With Left Ventricular Assist Devices for Destination Therapy
Park, Soon J., Milano, Carmelo A. , Tatooles, Antone, Rogers, Joseph G. , Adamson, Robert, Steidley, D. Eric , Ewald, Gregory A. , Sundareswaran, Kartik S., Farrar, David J. , Slaughter, Mark S.

Circulation: Heart Failure | January 27, 2012 | Volume: 5 | Issue: 2 | Pages: 241-248

10.1161/circheartfailure.111.963991 | PMID 22282104 Get It

Background— The HeartMate II (HMII) destination therapy (DT) trial demonstrated significant improvements in outcomes in continuous-flow left ventricular assist devices compared with patients implanted with the pulsatile-flow HeartMate XVE. The primary hypothesis of the current study is that trial patients enrolled after the initial data cohort would have better clinical outcomes. Methods and Results— Two hundred eighty-one patients who underwent HMII for DT from May 2007 to March 2009 (Mid Trial [MT] group) were compared with the initial 133 HMII patients from March 2005 to May 2007 (Early Trial [ET] group). Patient entry criteria were the same during the 2 time periods. Survival, adverse events, and quality of life were compared between the 2 groups. Baseline characteristics were similar between the groups. Compared with the ET group, patients in the MT group had reduced adverse event rates for bleeding requiring transfusions (1.66 versus 1.13 events per patient-year, P <0.001), sepsis (0.38 versus 0.27, P =0.025), device-related infections (0.47 versus 0.27, P <0.001), and hemorrhagic stroke (0.07 versus 0.03, P =0.01). Other event rates were similar between groups including ischemic stroke (0.06 versus 0.05 events per patient-year, P =0.57). Survival at 1 year in the MT group was 73% versus 68% in the ET group ( P =0.21). Additionally, there was a significant reduction in deaths caused by hemorrhagic stroke ( P =0.01). Quality of life improvements were significant in both the groups ( P <0.001). Conclusions— The benefit of DT therapy with the HMII is confirmed in subsequent trial patients, with improved adverse event rates and a strong trend for improvements in survival. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00121485.
Sirolimus as Primary Immunosuppression Attenuates Allograft Vasculopathy With Improved Late Survival and Decreased Cardiac Events After Cardiac Transplantation
Topilsky, Yan , Hasin, Tal , Raichlin, Eugenia , Boilson, Barry A. , Schirger, John A., Pereira, Naveen L. , Edwards, Brooks S., Clavell, Alfredo L. , Rodeheffer, Richard J. , Frantz, Robert P. , Maltais, Simon, Park, Soon J., Daly, Richard C. , Kushwaha, Sudhir S. , Lerman, Amir , Frantz, Robert P , Topilsky, Yan

Circulation | December 30, 2011 | Volume: 125 | Issue: 5 | Pages: 708-720

10.1161/circulationaha.111.040360 | PMID 22207715 Get It

Background— We retrospectively analyzed the potential of sirolimus as a primary immunosuppressant in the long-term attenuation of cardiac allograft vasculopathy progression and the effects on cardiac-related morbidity and mortality. Methods and Results— Forty-five cardiac transplant recipients were converted to sirolimus 1.2 years (0.2, 4.0) after transplantation with complete calcineurin inhibitor withdrawal. Fifty-eight control subjects 2.0 years (0.2, 6.5 years) from transplantation were maintained on calcineurin inhibitors. Age, sex, ejection fraction, and time from transplantation to baseline intravascular ultrasound study were not different ( P >0.2 for all) between the groups; neither were secondary immunosuppressants and use of steroids. Three-dimensional intravascular ultrasound studies were performed at baseline and 3.1 years (1.3, 4.6 years) later. Plaque index progression (plaque volume/vessel volume) was attenuated in the sirolimus group (0.7±10.5% versus 9.3±10.8%; P =0.0003) owing to reduced plaque volume in patients converted to sirolimus early (<2 years) after transplantation ( P =0.05) and improved positive vascular remodeling ( P =0.01) in patients analyzed late (>2 years) after transplantation. Outcome analysis in 160 consecutive patients maintained on 1 therapy was performed regardless of performance of intravascular ultrasound examinations. Five-year survival was improved with sirolimus (97.4±1.8% versus 81.8±4.9%; P =0.006), as was freedom from cardiac-related events (93.6±3.2% versus 76.9±5.5%; P =0.002). Conclusions— Substituting calcineurin inhibitor with sirolimus as primary immunosuppressant attenuates long-term cardiac allograft vasculopathy progression and may improve long-term allograft survival owing to favorable coronary remodeling. Because of the lack of randomization and retrospective nature of our analysis, the differences in outcome should be interpreted cautiously, and prospective clinical trials are required.
The Off-Pump Implantation of an Apicoaortic Valved Graft is Safe and Has No Negative Impact on Coronary Flow and Hemodynamics
Karapanos, N. Tsirikos, Suddendorf, Scott H., Li, Zhuo , Huebner, Marianne , Park, Soon J., Joyce, Lyle D., Daly, Richard C.

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | October 28, 2011 | Volume: 6 | Issue: 5 | Pages: 298-304

10.1097/imi.0b013e31823735ba | PMID 22436705 Get It

Objective To determine the hemodynamic effect of an off-pump Apicoaortic valved graft (AAVG) implantation, we performed a quantitative coronary flow analysis in a swine model of severe aortic stenosis. Methods In 10 swine, cardiac output, coronary flow, right common carotid artery flow, and internal mammary artery flow were measured along with left and right ventricular pressures and aortic and pulmonary artery pressures. A novel AAVG was implanted off-pump on the left ventricular (LV) apex using a specially designed implantation tool and anastomosed to the descending thoracic aorta. Aortic flow was measured proximally and distally of the AAVG-to-descending thoracic aorta anastomosis. After AAVG implantation, epicardial echo confirmed occlusion of the LV outflow tract by a valvuloplasty balloon. Baseline simultaneous measurements of all parameters were repeated after AAVG implantation and intravenous Dobutamine administration. Results The AAVG was implanted without any blood loss. After AAVG implantation and LV outflow tract occlusion, the aortic flow proximal to the AAVG-to-descending thoracic aorta anastomosis changed from antegrade (1508 ± 435 mL/min) to retrograde (–529 ± 241 mL/min, P < 0.001). All other measured parameters remained unchanged compared with baseline. After intravenous Dobutamine administration, LV pressure increased from 88 ± 20 to 184 ± 36 mm Hg (+209%, P < 0.0001) and coronary flow increased from 75 ± 34 to 193 ± 90 mL/min (+257%, P = 0.001). Conclusions The off-pump implantation of an AAVG is bloodless, safe, reproducible and has no negative impact on coronary flow and hemodynamics. In addition, to the best of our knowledge, this is the first study where blood flow in all coronary arteries was measured simultaneously during an AAVG implantation.