Citations

Mayo Clinic

Clear

152 citation(s) found for "An, Kai‐Nan".

The Effect of Pulling Angle on Rotator Cuff Mechanical Properties in a Canine In Vitro Model
Liu, Qian , Qi, Jun , Thoreson, Andrew R. , An, Kai‐Nan, Steinmann, Scott P. , Zhao, Chunfeng , Zhao, Chunfeng , Liu, Qian , Zhu, Weihong

Bioengineering | May 17, 2023 | Volume: 10 | Issue: 5 | Pages: 599

10.3390/bioengineering10050599 | PMID 37237669 Get It

The objective of this study was to examine the effect of pulling angle on time-zero mechanical properties of intact infraspinatus tendon or infraspinatus tendon repaired with the modified Mason-Allen technique in a canine model in vitro. Thirty-six canine shoulder samples were used. Twenty intact samples were randomly allocated into functional pull (135°) and anatomic pull (70°) groups (n = 10 per group). The remaining sixteen infraspinatus tendons were transected from the insertion and repaired using the modified Mason-Allen technique before being randomly allocated into functional pull or anatomic pull groups (n = 8 per group). Load to failure testing was performed on all specimens. The ultimate failure load and ultimate stress of the functional pulled intact tendons were significantly lower compared with anatomic pulled tendons (1310.2 ± 167.6 N vs. 1687.4 ± 228.2 N, p = 0.0005: 55.6 ± 8.4 MPa vs. 67.1 ± 13.3 MPa, p = 0.0334). For the tendons repaired with the modified Mason-Allen technique, no significant differences were observed in ultimate failure load, ultimate stress or stiffness between functional pull and anatomic pull groups. The variance of pulling angle had a significant influence on the biomechanical properties of the rotator cuff tendon in a canine shoulder model in vitro. Load to failure of the intact infraspinatus tendon was lower at the functional pulling position compared to the anatomic pulling position. This result indicates that uneven load distribution across tendon fibers under functional pull may predispose the tendon to tear. However, this mechanical character is not presented after rotator cuff repair using the modified Mason-Allen technique.
Apoptotic Body-Rich Media from Tenocytes Enhance Proliferation and Migration of Tenocytes and Bone Marrow Stromal Cells
Dong, Chenhui, Gingery, Anne , Amadio, Peter C. , An, Kai‐Nan, Moran, Steven L. , Zhao, Chunfeng , Zhao, Chunfeng , Gingery, Anne

International Journal of Molecular Sciences | September 29, 2022 | Volume: 23 | Issue: 19 | Pages: 11475

10.3390/ijms231911475 | PMID 36232777 Get It

The intrinsic healing following tendon injury is ideal, in which tendon progenitor cells proliferate and migrate to the injury site to directly bridge or regenerate tendon tissue. However, the mechanism determining why and how those cells are attracted to the injury site for tendon healing is not understood. Since the tenocytes near the injury site go through apoptosis or necrosis following injury, we hypothesized that secretions from injured tenocytes might have biological effects on cell proliferation and migration to enhance tendon healing. Tenocyte apoptosis was induced by 24 h cell starvation. Apoptotic body-rich media (T-ABRM) and apoptotic body-depleted media (T-ABDM) were collected from culture media after centrifuging. Tenocytes and bone marrow-derived stem cells (BMDSCs) were isolated and cultured with the following four media: (1) T-ABRM, (2) T-ABDM, (3) GDF-5, or (4) basal medium with 2% fetal calf serum (FCS). The cell activities and functions were evaluated. Both T-ABRM and T-ABDM treatments significantly stimulated the cell proliferation, migration, and extracellular matrix synthesis for both tenocytes and BMDSCs compared to the control groups (GDF-5 and basal medium). However, cell proliferation, migration, and extracellular matrix production of T-ABRM-treated cells were significantly higher than the T-ABDM, which indicates the apoptotic bodies are critical for cell activities. Our study revealed the possible mechanism of the intrinsic healing of the tendon in which apoptotic bodies, in the process of apoptosis, following tendon injury promote tenocyte and stromal cell proliferation, migration, and production. Future studies should analyze the components of the apoptotic bodies that play this role, and, thus, the targeting of therapeutics can be developed.
Biomedical Imaging Analysis and Mesh Generation for Three-Dimensional Finite Element Models
Ehnes, Dale L., Stone, J.J., An, Kai‐Nan

Advances in Bioengineering | March 3, 2022 | Volume: No volume available | Issue: No issue available | Pages: 257-258

10.1115/imece1997-0326 Get It

Abstract The methodological procedure for generating three-dimensional (3-D) finite element analysis (FEA) geometry models from CT or MRI medical imaging scan data was developed in this study. Medical images of a human scapula and a fifth proximal phalangeal bone were used to demonstrate the techniques of image processing and generation of 3-D FEA models. The biomedical imaging quality and its effects on the outcome of the FEA geometry model was also studied.
Human synoviocyte lubricin and bovine synovial fluid lubricin equally improve gliding resistance in a canine model in vitro
Kohn, Mark D. , Sun, Yu-Long, Zhao, Chunfeng , Thoreson, Andrew R. , Jay, Gregory D. , An, Kai‐Nan , Amadio, Peter C.

Bio-Medical Materials and Engineering | December 2, 2019 | Volume: 21 | Issue: 5-6 | Pages: 281-289

10.3233/bme-2012-0676 | PMID 22561248 Get It

A practical biomechanical model of the index finger simulating the kinematics of the muscle/tendon excursions
Wu, John Z. , An, Kai‐Nan , Cutlip, Robert G., Dong, Ren G.

Bio-Medical Materials and Engineering | December 2, 2019 | Volume: 20 | Issue: 2 | Pages: 89-97

10.3233/bme-2010-0618 | PMID 20592446 Get It

Shear Wave Elastography Can Predict Passive Stiffness of Supraspinatus Musculotendinous Unit During Arthroscopic Rotator Cuff Repair for Presurgical Planning
Itoigawa, Yoshiaki , Maruyama, Yuichiro, Kawasaki, Takayuki , Wada, Tomoki , Yoshida, Keiichi , An, Kai‐Nan , Kaneko, Kazuo, Wada, Tomoki

Arthroscopy | August 1, 2018 | Volume: 34 | Issue: 8 | Pages: 2276-2284

10.1016/j.arthro.2018.01.059 | PMID 29685838 Get It

Purpose To determine the feasibility of shear wave elastography (SWE) with B‐mode ultrasound in predicting the stiffness of the rotator cuff muscle before arthroscopic rotator cuff repair to evaluate the difficulty of the surgical procedure, as well as to compare SWE with the Goutallier stage on magnetic resonance imaging (MRI). Methods Thirty‐eight patients with a full‐thickness supraspinatus tear requiring arthroscopic rotator cuff repair participated. The Goutallier stage of fatty infiltration on MRI was measured before surgery, as was the SWE modulus of the anterior superficial, anterior deep, posterior superficial, and posterior deep (PD) regions of the supraspinatus muscle. To measure the stiffness of the supraspinatus musculotendinous unit during surgery, the supraspinatus tendon was axially stretched until the anatomic insertion site was reached, and force per deformation was recorded. The correlation between stiffness of the supraspinatus and SWE value in each region of the supraspinatus muscle or Goutallier stage was determined. In addition, patients were divided into 2 groups: (1) In the complete footprint coverage group, greater than 50% of the footprint was covered during the stiffness measurement, and (2) in the incomplete footprint coverage group, less than 50% of the footprint was covered during the stiffness measurement. Differences in SWE value and Goutallier stage were measured between the 2 groups. Results The best correlation of stiffness with the SWE modulus of the PD muscle of the supraspinatus was R = 0.69, and the correlation of stiffness with the Goutallier stage on MRI was R = 0.48. The SWE value of the PD region was greater in the incomplete footprint coverage group than in the complete footprint coverage group, although the Goutallier stage was not significantly different. Conclusions The highest correlation with stiffness of the supraspinatus musculotendinous unit was with the SWE modulus of the PD muscle, as compared with SWE evaluation of the other regions or the Goutallier stage on MRI. Ultrasound SWE can predict the stiffness of the supraspinatus musculotendinous unit best. Clinical Relevance Rotator cuff retraction adds difficulty to arthroscopic rotator cuff repair. Ultrasound SWE may be used for presurgical planning.
Acromial Fractures in Reverse Shoulder Arthroplasty: A Clinical and Radiographic Analysis
Werthel, Jean-David , Veen, Steven C. van , Elhassan, Bassem T. , An, Kai‐Nan, Cofield, Robert H. , Sperling, John W. , Schoch, Bradley S.

Journal of Shoulder and Elbow Arthroplasty | May 25, 2018 | Volume: 2 | Issue: No issue available | Pages: No page available

10.1177/2471549218777628 Get It

Background The purpose of this study is to assess the incidence of acromial stress fractures in a population of reverse shoulder arthroplasties (RSA) and determine potential risk factors for fracture. Patients and Methods Between August 2004 and December 2013, 1082 primary RSA were performed at a single institution. Twelve (1.11%) patients were diagnosed with a postoperative acromial stress fracture. This group was case-matched to a control group of 48 shoulders. Clinical and radiographic risk factors for fracture were assessed. Results Compared to controls, fractures were less satisfied with their outcome despite equivalent American Shoulder and Elbow Surgeons scores, pain scores, and range of motion. Osteoporosis was significantly associated with acromial fractures ( P = .027). A smaller lateral offset of the greater tuberosity, greater arm lengthening, and a thinner acromion were more common in the fracture group ( P = .026, P = .004, and P = .008, respectively). Conclusions In summary, postoperative acromial stress fractures appear to be incidental lesions with little influence on the outcome after RSA. The combination of a thin acromion and superior migration of the humeral head increase the risk of acromial fracture. Lateralized designs that do not excessively verticalize the deltoid line of pull on the acromion may decrease the risk of postoperative acromial fractures.
Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction
Wei, Zhuang, Reisdorf, Ramona L., Thoreson, Andrew R. , Moran, Steven L. , An, Kai‐Nan , Amadio, Peter C. , Zhao, Chunfeng , Wei, Zhuang, Jay, Gregory D.

Journal of Bone and Joint Surgery | April 4, 2018 | Volume: 100 | Issue: 7 | Pages: e42

10.2106/jbjs.17.00925 | PMID 29613931 Get It

Background: Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Methods: Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. Results: The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. Conclusions: FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Clinical Relevance: Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.
A 3D finite element model of prophylactic vertebroplasty in the metastatic spine: Vertebral stability and stress distribution on adjacent vertebrae
Salvatore, Giuseppe , Giambini, Hugo , Ciuffreda, Mauro , Thoreson, Andrew R. , An, Kai‐Nan , Thoreson, Andrew, Berton, Alessandra , Longo, Umile Giuseppe , Denaro, Vincenzo

The Journal of Spinal Cord Medicine | February 15, 2018 | Volume: 43 | Issue: 1 | Pages: 39-45

10.1080/10790268.2018.1432309 | PMID 29446706 Get It

ELASTICITY MEASUREMENTS BY SHEAR WAVE ELASTOGRAPHY: COMPARISON AND SELECTION OF SHEAR WAVE, RAYLEIGH WAVE AND LAMB WAVE THEORY
Xu, Hao , MO, JIAN-QIANG, Chen, Shigao , An, Kai‐Nan , Luo, Zong-Ping

Journal of Mechanics in Medicine and Biology | February 8, 2018 | Volume: 18 | Issue: 01 | Pages: 1750119

10.1142/s0219519417501196 Get It

Shear wave elastography (SWE) is a powerful method for the diagnosis of tissue disorders or degeneration based on tissue elasticity. In SWE application, it was recognized that the wave speed depends not only on the tissue elasticity but also on the structural shape, leading to different theoretical models. For liver, skin and myocardium, the appropriate theoretical model is known to be shear wave, Rayleigh wave and Lamb wave theory, respectively. Therefore, appropriate theoretical model should be adopted for the proper application of SWE. In this study, we verify these theoretical models in gelatin samples of different thicknesses, using experimental and numerical SWE tests. The results indicate that the wave speed was influenced by the ratio of the wavelength and sample thickness and the measurement region. Based on these results, the selection of theoretical model could be divided into three cases, and the appropriate theoretical model can be selected accordingly.