Citations

Mayo Clinic

Showing 10 of 108376 citations.

Optimal Allocation of Surgery Blocks to Operating Rooms Under Uncertainty
Miller, Andrew J. , Balasubramanian, Hari , Huschka, Todd R., Denton, Brian T.

Operations Research | March 25, 2010 | Volume: 58 | Issue: 4-part-1 | Pages: 802-816

10.1287/opre.1090.0791 Get It

The allocation of surgeries to operating rooms (ORs) is a challenging combinatorial optimization problem. There is also significant uncertainty in the duration of surgical procedures, which further complicates assignment decisions. In this paper, we present stochastic optimization models for the assignment of surgeries to ORs on a given day of surgery. The objective includes a fixed cost of opening ORs and a variable cost of overtime relative to a fixed length-of-day. We describe two types of models. The first is a two-stage stochastic linear program with binary decisions in the first stage and simple recourse in the second stage. The second is its robust counterpart, in which the objective is to minimize the maximum cost associated with an uncertainty set for surgery durations. We describe the mathematical models, bounds on the optimal solution, and solution methodologies, including an easy-to-implement heuristic. Numerical experiments based on real data from a large health-care provider are used to contrast the results for the two models and illustrate the potential for impact in practice. Based on our numerical experimentation, we find that a fast and easy-to-implement heuristic works fairly well, on average, across many instances. We also find that the robust method performs approximately as well as the heuristic, is much faster than solving the stochastic recourse model, and has the benefit of limiting the worst-case outcome of the recourse problem.
Evaluation of Mycobacterium avium Complex Clarithromycin Susceptibility Testing Using SLOMYCO Sensititre Panels and JustOne Strips
Hall, Leslie, Abbenyi, Adeline, Eisberner, Justin J., Brown‐Elliott, Barbara A. , Pratt, Cody J., McGlasson, Maria C., Beierle, Keanan D., Wohlfiel, Sherri L., Deml, Sharon M., Wallace, Richard J. , Wengenack, Nancy L. , Babady, N. Esther

Journal of Clinical Microbiology | March 25, 2010 | Volume: 48 | Issue: 5 | Pages: 1749-1752

10.1128/jcm.01936-09 | PMID 20335412 Get It

ABSTRACT The SLOMYCO Sensititre panel and the custom JustOne strip (both from TREK Diagnostic Systems, Cleveland, OH) were evaluated for susceptibility testing of Mycobacterium avium complex isolates against clarithromycin. Seventy-one archived and prospectively collected isolates were tested using both the SLOMYCO panel and the JustOne strip, and the results were compared to those obtained using the BACTEC 460 (BD, Sparks, MD) radiometric method and a broth microdilution reference method. Results obtained by the SLOMYCO panel and the JustOne strip agreed with the BACTEC 460 method for 64/71 isolates (90%). Similarly, concordance with the broth microdilution method was 40/43 isolates (93%) for both test systems. The effect of the source medium on inoculum preparation was evaluated, and there were no differences noted in MICs, regardless of whether the inoculum was prepared from isolates grown in Middlebrook 7H9 medium, on Middlebrook 7H10 agar, or in VersaTREK broth culture bottles (Trek Diagnostics). Clarithromycin susceptibility testing of MAC using the SLOMYCO panel and the JustOne strip methods is easy to set up and simple to read and is readily incorporate into the clinical laboratory. These systems offer advantages over the BACTEC 460 system including the lack of a need for radioactive substrates, sharps, or costly instrumentation.
Automated Prone Positioning and Axial Rotation in Critically Ill, Nontrauma Patients With Acute Respiratory Distress Syndrome (ARDS)
Arasi, Lisa C., Canabal, Juan, Kramer, David J., Bajwa, Abubakr A.

Journal of Intensive Care Medicine | March 25, 2010 | Volume: 25 | Issue: 2 | Pages: 121-125

10.1177/0885066609356050 | PMID 20338893 Get It

The Effects of Walking and Cycling Computer Workstations on Keyboard and Mouse Performance
Straker, Leon , Levine, James A. , Campbell, Amity

Human Factors: The Journal of the Human Factors and Ergonomics Society | March 24, 2010 | Volume: 51 | Issue: 6 | Pages: 831-844

10.1177/0018720810362079 | PMID 20415158 Get It

Objective: This study aimed to determine the effects of active workstation designs on speed and error during typing, mouse pointing, and combined type and mouse-use tasks. Background: Office ergonomics has focused on musculoskeletal disorder prevention; however, increasing computer-based work also increases health risks associated with inactivity. Workstations allowing computer users to walk or cycle while performing computer tasks have been shown to demand sufficient energy expenditure to result in significant health benefits. However the performance effects of being active while using a computer have not been documented. Method: Thirty office workers (16 female, 15 touch typists) performed standardized computer tasks in six workstation conditions: sitting, standing, walking at 1.6 km/h and 3.2 km/h, and cycling at 5 and 30 watts. Performance, perceived performance, and heart rate were measured. Results: Computer task performance was lower when walking and slightly lower when cycling, compared with chair sitting. Standing performance was not different from sitting performance. Mouse performance was more affected than typing performance. Performance decrements were equal for females and males and for touch typists and nontouch typists. Conclusion: Performance decrements maybe related to both biomechanical and cognitive processes. Active workstations may be less suitable for mouse-intensive work and susceptible users. Application: Although active workstations may result in some decrement in performance, their ability to increase daily energy expenditure may make them a feasible solution for workplace inactivity.
Advanced Heart Failure and Nocturnal Hypoxaemia Due to Central Sleep Apnoea are Associated with Increased Serum Erythropoietin
Calvin, Andrew D. , Steensma, David P. , Pérez, José A., Walt, Christelle van der, Fitz‐Gibbon, Jennifer M., Scott, Christopher G. , Olson, Lyle J. , Somers, Virend K. , Scott, Christopher , Steensma, David P , Calvin, Andrew D

European Journal of Heart Failure | March 24, 2010 | Volume: 12 | Issue: 4 | Pages: 354-359

10.1093/eurjhf/hfq005 | PMID 20335353 Get It

Abstract Aims Central sleep apnoea (CSA) and increased serum erythropoietin (EPO) concentration have each been associated with adverse prognosis in heart failure (HF) patients. The aim of this study was to examine the relationship between nocturnal hypoxaemia due to CSA and the serum EPO concentration in patients with HF. Methods and results Heart failure subjects (n = 33) and healthy controls (n = 18) underwent polysomnography (PSG) for diagnosis of CSA and identification and quantification of hypoxaemia. Blood collection for measurement of EPO was performed immediately post-PSG. For the analysis, HF subjects were dichotomized into subgroups defined by the presence or absence of CSA and by HF severity. Multivariate analyses were performed to evaluate the relationships of hypoxaemia and advanced HF to EPO concentration. Mean EPO concentration was 62% higher for HF subjects with CSA than for healthy controls (P = 0.004). The magnitude of nocturnal hypoxaemia was significantly and positively related to EPO concentration (r = 0.45, P = 0.02). Advanced HF was also significantly and positively related to EPO concentration (r = 0.43, P = 0.02). On multivariate analysis, the presence of combined nocturnal hypoxaemia and advanced HF yielded greater correlation to EPO concentration than either factor alone (r = 0.57, P = 0.04 and P = 0.05, respectively). Linear regression demonstrated that the combination of New York Heart Association Class and CSA was strongly associated with EPO concentration (P < 0.0001). Conclusion In non-anaemic HF patients, advanced HF and hypoxaemia due to CSA may each be independently associated with increased serum EPO concentration.
Using temporal cycles in spontaneous speech to quantify linguistic impairments in patients with neurodegenerative disorders.
Kaiser, Eden, Pakhomov, Serguei , Boley, Daniel , Birnbaum, Angela K. , Knopman, David S.

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1996-1996

10.1121/1.3385172 Get It

Fronto-temporal lobar degeneration (FTLD) is a form of dementia which may manifest through symptoms similar to Alzheimer’s, including language-specific impairment. Linguistic manifestations of the disorder are often described in subjective assessments of the disorder, but not always easily quantifiable using objective tests. This paper investigates a speech characteristic not yet assessed in FTLD patients, that of “temporal cycles” [Henderson et al. (1966); Butterworth and Goldman-Eisler (1979)]. Temporal cycles in the speech of healthy adults consist of alternating and roughly equal periods of fluent and hesitant speech [Roberts and Kirsner (2000)]. A time series analysis of temporal cycles was conducted using spontaneous speech from 45 adults diagnosed with FTLD. Patients’ cognitive functioning was assessed using the language-specific clinical dementia rating (CDR) scale by board-certified neurologists. Periodicity of temporal cycles was quantified using the proportion of the energy in the highest peak to the total energy in the power spectrum. It was found that this measure was correlated with independent CDR assessments. The results of this study indicate that temporal cycles may be used to characterize the effects of neurodegenerative disorders on speech communication. [Work supported by US NIA Grants Nos. R01-AG023195, P50-AG16574, P30-AG19610, and NIH NIA-1R01AG026390, and Univ. of MN Academic Health Center.]
Calculations of intensities for radiation force modeling with the commercial software package FOCUS.
McGough, Robert J., VanderLaan, Donald, Dutch, A., Urban, Matthew W. , Urban, Matthew W

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1828-1828

10.1121/1.3384242 Get It

Rapid calculations of the intensity are required for models of the radiation force generated by linear ultrasound phased arrays. To determine the computation times and numerical errors produced by two medical ultrasound simulation packages, namely, FIELD II and FOCUS, comparisons of the calculated pressures and intensities are performed using a simulated Vermon L5 phased array probe with 128 active elements. In these simulations, the array generates a fixed focus 25 mm from the array for a 5-MHz excitation, and the pressure field is computed on a 133 × 133 × 261 rectilinear grid that is centered at the focus. Half wavelength sampling is employed in all three directions. In FIELD II, this calculation takes approximately 4 h on a 64-bit laptop running Linux, and in FOCUS, the same calculation takes less than 4 min on the same computer. The numerical errors are also much smaller with FOCUS. Details of the simulation approaches employed for this transducer model will be presented, including selection of FIELD II and FOCUS simulation parameters and calculations of the reference pressure field for error evaluations. The impact of numerical errors on shear wave calculations will also be discussed.
Beamforming for vibro-acoustography using a 1.75D array transducer.
Urban, Matthew W. , Fatemi, Mostafa , Alizad, Azra , Urban, Matthew W

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1828-1828

10.1121/1.3384241 Get It

Vibro-acoustography is an ultrasound-based imaging modality that maps the acoustic response of an object induced by acoustic radiation force. The method employs two ultrasound beams with frequencies separated by a small difference, typically in the kilohertz range. Using a 1.75D array transducer, which has multiple rows of elements, offers an advantage over linear array transducers because it allows for focusing in the elevation direction. We have performed simulations of different arrangements for the apertures assigned to the two ultrasound frequencies and evaluated resolution and sidelobe levels for different arrangements. However, the large size of the elements produces grating lobes in the transmitted fields. We will describe metrics for evaluating grating lobe levels compared to the main lobe of the transmitted field as a quantitative approach to optimize aperture design. We present experimental measurements of the transmitted field and compare with simulation results. Finally, we present imaging results from phantom experiments. This beamforming study is directed toward improving vibro-acoustography image formation using a General Electric Vivid 7 scanner for breast and thyroid imaging. [Mayo Clinic and two of the authors have potential financial interest related to devices or technology referenced above. Work supported by NIH Grant No. R21CA121579 and AIUM Award No. AIUM-EER#1.]
Kramers–Kronig relationships applied to shear wave propagation in soft tissues.
Amador, Carolina , Greenleaf, James F. , Urban, Matthew W. , Chen, Shigao

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1731-1731

10.1121/1.3383449 Get It

Multiple methods have been proposed to characterize the viscoelastic material properties of soft tissues to differentiate normal from pathological tissue. Shearwave dispersion ultrasound vibrometry is a method that uses the dispersion of the shear wave velocity to characterize tissue shear elasticity and viscosity. It has recently been shown [M. W. Urban and J. F. Greenleaf, Phys. Med. Biol. 54, 5919–5933 (2009)] that the Kramers–Kronig relationships can be applied to shear wave measurements in ex vivo skeletal muscle over a frequency bandwidth of 100–600 Hz. We will describe this process where shear wave attenuation is modeled using a power law, and the shear wave velocity dispersion is predicted by applying the Kramers–Kronig relationships. In this study, we apply this method to shear wave propagation measurements made in different soft tissues such as ex vivo porcine skeletal muscle and kidney and in vivo porcine liver. The shear wave velocity predictions using the Kramers–Kronig relationships agree with the velocity measurements. The mean square error for these tissues ranged from 0.0024–0.0625 m2/s2. The Kramers–Kronig relationships can be used in shear wave propagation measurements in different types of soft tissues. [This work was supported in part by NIH Grants Nos. EB002167 and DK082408.]
Modulation of ultrasound to produce multifrequency radiation force
Urban, Matthew W. , Fatemi, Mostafa , Greenleaf, James F. , Fatemi, Mostafa , Urban, Matthew W

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3 | Pages: 1228-1238

10.1121/1.3294487 | PMID 20329821 Get It

Dynamic radiation force has been used in several types of applications, and is performed by modulating ultrasound with different methods. By modulating ultrasound, energy can be transmitted to tissue, in this case a dynamic force to elicit a low frequency cyclic displacement to inspect the material properties of the tissue. In this paper, different types of modulation are explored including amplitude modulation (AM), double sideband suppressed carrier amplitude modulation AM, linear frequency modulation, and frequency-shift keying. Generalized theory is presented for computing the radiation force through the short-term time average of the energy density for these various types of modulation. Examples of modulation with different types of signals including sine waves, square waves, and triangle waves are shown. Using different modulating signals, multifrequency radiation force with different numbers of frequency components can be created, and can be used to characterize tissue mimicking materials and soft tissue. Results for characterization of gelatin phantoms using a method of vibrating an embedded sphere are presented. Different degrees of accuracy were achieved using different modulation techniques and modulating signals. Modulating ultrasound is a very flexible technique to produce radiation force with multiple frequency components that can be used for various applications.