Citations

Mayo Clinic

Clear

112 citation(s) found for "Quaintance, Kerryl Greenwood".

Activity of Tedizolid in Methicillin-Resistant Staphylococcus aureus Experimental Foreign Body-Associated Osteomyelitis
Park, Kyung‐Hwa , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Mandrekar, Jayawant, Patel, Robin

Antimicrobial Agents and Chemotherapy | August 23, 2016 | Volume: 60 | Issue: 11 | Pages: 6568-6572

10.1128/aac.01248-16 | PMID 27550347 Get It

ABSTRACT We compared tedizolid alone and tedizolid with rifampin to rifampin and vancomycin plus rifampin in a rat model of methicillin-resistant Staphylococcus aureus (MRSA) foreign body-associated osteomyelitis. The study strain was a prosthetic joint infection-associated isolate. Steady-state pharmacokinetics for intraperitoneal administration of tedizolid, vancomycin, and rifampin were determined in uninfected rats. MRSA was inoculated into the proximal tibia, and a wire was implanted. Four weeks later, the rats were treated intraperitoneally for 21 days with tedizolid ( n = 14), tedizolid plus rifampin ( n = 11), rifampin ( n = 16), or vancomycin plus rifampin ( n = 13). Seventeen rats received no treatment. After treatment, quantitative bone cultures were performed. Blood was obtained for determination of drug trough concentrations in the tedizolid and tedizolid plus rifampin groups. The mean peak plasma concentration and mean area under the concentration-time curve from time zero to 24 h for tedizolid were 12 μg/ml and 60 μg · h/ml, respectively. The bacterial loads in all treatment groups were significantly lower than those in the control group; those in the tedizolid- plus rifampin-treated animals were not significantly different from those in the vancomycin- plus rifampin-treated animals. The range of mean plasma trough concentrations in the tedizolid group was 0.44 to 0.73 μg/ml. Although neither tedizolid nor vancomycin resistance was detected in isolates recovered from bones, rifampin resistance was detected in 10 animals (63%) in the rifampin group, 8 animals (73%) in the tedizolid plus rifampin group, and a single animal (8%) in the vancomycin plus rifampin group. Tedizolid alone or tedizolid combined with rifampin was active in a rat model of MRSA foreign body-associated osteomyelitis. The emergence of rifampin resistance was noted in animals receiving tedizolid plus rifampin.
Selected Antimicrobial Activity of Topical Ophthalmic Anesthetics
Reynolds, Margaret , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Pulido, José S. , Reynolds, Margaret M, Patel, Robin , Reynolds, Margaret M

Translational Vision Science & Technology | July 5, 2016 | Volume: 5 | Issue: 4 | Pages: 2

10.1167/tvst.5.4.2 | PMID 27441100 Get It

Antimicrobial Susceptibility and Clonality of Clinical Ureaplasma Isolates in the United States
Fernández, Javier , Karau, Melissa J. , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Antimicrobial Agents and Chemotherapy | June 1, 2016 | Volume: 60 | Issue: 8 | Pages: 4793-4798

10.1128/aac.00671-16 | PMID 27246773 Get It

ABSTRACT Ureaplasma urealyticum and Ureaplasma parvum are pathogens involved in urogenital tract and intrauterine infections and also in systemic diseases in newborns and immunosuppressed patients. There is limited information on the antimicrobial susceptibility and clonality of these species. In this study, we report the susceptibility of 250 contemporary isolates of Ureaplasma (202 U. parvum and 48 U. urealyticum isolates) recovered at Mayo Clinic, Rochester, MN. MICs of doxycycline, azithromycin, ciprofloxacin, tetracycline, erythromycin, and levofloxacin were determined by broth microdilution, with MICS of the last three interpreted according to CLSI guidelines. Levofloxacin resistance was found in 6.4% and 5.2% of U. parvum and U. urealyticum isolates, respectively, while 27.2% and 68.8% of isolates, respectively, showed ciprofloxacin MICs of ≥4 μg/ml. The resistance mechanism of levofloxacin-resistant isolates was due to mutations in parC , with the Ser83Leu substitution being most frequent, followed by Glu87Lys. No macrolide resistance was found among the 250 isolates studied; a single U. parvum isolate was tetracycline resistant. tet (M) was found in 10 U. parvum isolates, including the single tetracycline-resistant isolate, as well as in 9 isolates which had low tetracycline and doxycycline MICs. Multilocus sequence typing (MLST) performed on a selection of 46 isolates showed high diversity within the clinical Ureaplasma isolates studied, regardless of antimicrobial susceptibility. The present work extends previous knowledge regarding susceptibility to antimicrobial agents, resistance mechanisms, and clonality of Ureaplasma species in the United States.
Differential Antimicrobial Susceptibilities of Granulicatella adiacens and Abiotrophia defectiva
Mushtaq, Ammara , Greenwood‐Quaintance, Kerryl E. , Cole, Nicolynn C., Kohner, Peggy C., Ihde, Sherry M., Strand, Gregory J. , Harper, Lance W., Virk, Abinash, Patel, Robin , Virk, Abinash , Patel, Robin

Antimicrobial Agents and Chemotherapy | May 24, 2016 | Volume: 60 | Issue: 8 | Pages: 5036-5039

10.1128/aac.00485-16 | PMID 27216060 Get It

ABSTRACT MICs of 25 Abiotrophia defectiva and 109 Granulicatella adiacens isolates were determined by broth microdilution. Using CLSI breakpoints, the susceptibilities of A. defectiva and G. adiacens isolates were, respectively, 24% and 34% to penicillin, 92% and 22% to ceftriaxone, 48% and 3% to cefepime, 72% and 87% to meropenem, 92% and 10% to cefotaxime, 100% and 97% to levofloxacin, 92% and 80% to clindamycin, and 24% and 50% to erythromycin. All isolates were susceptible to vancomycin. In the penicillin-susceptible subgroup, all A. defectiva isolates were susceptible to ceftriaxone; however, 62% of G. adiacens isolates were ceftriaxone nonsusceptible.
Antimicrobial-Loaded Bone Cement Does Not Negatively Influence Sonicate Fluid Culture Positivity for Diagnosis of Prosthetic Joint Infection
Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Patel, Robin , Park, Kyung Hwa , Abdel, Matthew P. , Patel, Robin

Journal of Clinical Microbiology | March 31, 2016 | Volume: 54 | Issue: 6 | Pages: 1656-1659

10.1128/jcm.00516-16 | PMID 27030490 Get It

ABSTRACT We compared culture results to investigate the influence of antimicrobial-loaded cement on sonicate fluid culture positivity for the diagnosis of prosthetic joint infection. Fifty-four subjects were assessed. The sensitivities of sonicate fluid culture were 77.8% (14 of 18) in subjects with an antimicrobial-loaded cemented prosthesis and 58.3% (21 of 36) in subjects with an antimicrobial-free prosthesis.
Direct Electrical Current Reduces Bacterial and Yeast Biofilm Formation
Ruiz‐Ruigómez, María , Badiola, Jon , Schmidt-Malan, Suzannah M., Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Greenwood-Quaintance, Kerryl, Patel, Robin

International Journal of Bacteriology | March 17, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-6

10.1155/2016/9727810 | PMID 27073807 Get It

New strategies are needed for prevention of biofilm formation. We have previously shown that 24 hr of 2,000 µA of direct current (DC) reducesStaphylococcus epidermidisbiofilm formationin vitro. Herein, we examined the effect of a lower amount of DC exposure onS. epidermidis,Staphylococcus aureus,Escherichia coli,Pseudomonas aeruginosa,Propionibacterium acnes, andCandida albicansbiofilm formation. 12 hr of 500 µA DC decreasedS. epidermidis,S. aureus,E. coli, andP. aeruginosabiofilm formation on Teflon discs by 2, 1, 1, and 2 log10cfu/cm2, respectively (p<0.05). Reductions inS. epidermidis,S. aureus, andE. colibiofilm formation were observed with as few as 12 hr of 200 µA DC (2, 2 and 0.4 log10 cfu/cm2, resp.); a 1 log10 cfu/cm2reduction inP. aeruginosabiofilm formation was observed at 36 hr. 24 hr of 500 µA DC decreasedC. albicansbiofilm formation on Teflon discs by 2 log10 cfu/cm2. No reduction inP. acnesbiofilm formation was observed. 1 and 2 log10 cfu/cm2reductions inE. coliandS. epidermidisbiofilm formation on titanium discs, respectively, were observed with 12 hr of exposure to 500 µA. Electrical current is a potential strategy to reduce biofilm formation on medical biomaterials.
Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles
Peel, Trisha , Dylla, Brenda L., Lynch, David T. , Greenwood‐Quaintance, Kerryl E. , Cheng, Allen , Mandrekar, Jayawant N. , Patel, Robin , Peel, Trisha N, Hughes, John G, Hughes, John , Patel, Robin

mBio | January 29, 2016 | Volume: 7 | Issue: 1 | Pages: No page available

10.1128/mbio.01776-15 | PMID 26733067 Get It

ABSTRACT Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media ( P < 0.0001), with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster. IMPORTANCE Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of tissue samples from around the prosthetic joint into blood culture bottles. This study demonstrated that, compared to current laboratory practices, this new technique increased the detection of infection. These findings are important for patient care to allow timely and accurate diagnosis of infection.
Antibiofilm Activity of Electrical Current in a Catheter Model
Voegele, Paul, Badiola, Jon , Schmidt-Malan, Suzannah M., Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | December 29, 2015 | Volume: 60 | Issue: 3 | Pages: 1476-1480

10.1128/aac.01628-15 | PMID 26711752 Get It

ABSTRACT Catheter-associated infections are difficult to treat with available antimicrobial agents because of their biofilm etiology. We examined the effect of low-amperage direct electrical current (DC) exposure on established bacterial and fungal biofilms in a novel experimental in vitro catheter model. Staphylococcus epidermidis , Staphylococcus aureus , Escherichia coli , Pseudomonas aeruginosa , and Candida parapsilosis biofilms were grown on the inside surfaces of polyvinyl chloride (PVC) catheters, after which 0, 100, 200, or 500 μA of DC was delivered via intraluminally placed platinum electrodes. Catheter biofilms and intraluminal fluid were quantitatively cultured after 24 h and 4 days of DC exposure. Time- and dose-dependent biofilm killing was observed with all amperages and durations of DC administration. Twenty-four hours of 500 μA of DC sterilized the intraluminal fluid for all bacterial species studied; no viable bacteria were detected after treatment of S. epidermidis and S. aureus biofilms with 500 μA of DC for 4 days.
Superantigen-Producing Staphylococcus aureus Elicits Systemic Immune Activation in a Murine Wound Colonization Model
Kim, Choon Kwan , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Tilahun, Ashenafi Y. , Krogman, Ashton , David, Chella S., Pritt, Bobbi S. , Patel, Robin , Rajagopalan, Govindarajan , Kim, Choon K, Patel, Robin , Pritt, Bobbi S

Toxins | December 9, 2015 | Volume: 7 | Issue: 12 | Pages: 5308-5319

10.3390/toxins7124886 | PMID 26670252 Get It

Staphylococcus aureus, the most common cause of wound infection, produces several exotoxins, including superantigens (SAgs). SAgs are the potent activators of the immune system. Given this unique property, we hypothesized that SAgs produced by S. aureus in wounds would have local, as well as systemic immunologic effects. We tested our hypothesis using a novel staphylococcal skin wound infection model in transgenic mice expressing HLA-DR3. Skin wounds were left uninfected or colonized with S. aureus strains producing SAgs or an isogenic strain not producing any SAg. Animals with wounds challenged with SAg-producing S. aureus had increased morbidity and lower serum IL-17 levels compared to those challenged with the SAg non-producing S. aureus (p = 0.027 and p = 0.032, respectively). At Day 8 following microbial challenge, compared to mice with uninfected wounds, the proportion of Vβ8+CD4+ T cells was increased, while the proportion of Vβ8+CD8+ T cells was decreased only in the spleens of mice challenged with SAg-producing S. aureus (p < 0.001). No such changes were measured in mice challenged with SAg non-producing S. aureus. Lungs, livers and kidneys from mice challenged with SAg-producing, but not SAg non-producing, S. aureus showed inflammatory changes. Overall, SAg-mediated systemic immune activation in wounds harboring S. aureus may have clinical implications.
Evaluation of a Genus- and Group-Specific Rapid PCR Assay Panel on Synovial Fluid for Diagnosis of Prosthetic Knee Infection
Melendez, Dante P. , Greenwood‐Quaintance, Kerryl E. , Berbari, Elie F. , Osmon, Douglas R. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | November 5, 2015 | Volume: 54 | Issue: 1 | Pages: 120-126

10.1128/jcm.02302-15 | PMID 26537446 Get It

ABSTRACT We evaluated a genus- and group-specific PCR assay panel using 284 prosthetic knee synovial fluid samples collected from patients presenting to our institution with implant failure. Using the Musculoskeletal Infection Society diagnostic criteria, 88 and 196 samples were classified as showing prosthetic joint infection (PJI) and aseptic failure (AF), respectively. Sensitivities of the synovial fluid PCR panel and culture were 55.6% and 76.1% ( P ≤ 0.001), respectively, and specificities were 91.8% and 97.4% ( P = 0.016), respectively. Among the 70 subjects who had received antibiotics within the month preceding synovial fluid aspiration (48 of whom had PJI), PCR panel and synovial fluid culture sensitivities were 64.5% and 85.4%, respectively ( P < 0.0001). In this group, the PCR panel detected Staphylococcus aureus in two culture-negative PJI cases. Overall, the evaluated molecular diagnostic tool had low sensitivity when applied to synovial fluid.