Hepatitis C Virus Genotypes in Clinical Specimens Tested at a National Reference Testing Laboratory in the United States
Germer, Jeffrey J., Mandrekar, Jayawant N. , Bendel, Jordan L., Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | May 26, 2011 | Volume: 49 | Issue: 8 | Pages: 3040-3043

10.1128/jcm.00457-11 Get It

ABSTRACTHepatitis C virus (HCV) genotype (GT) distribution and frequency were studied among 22,407 unique specimens tested at a national reference testing laboratory. Subjects with HCV GT 3 were younger (P< 0.0001) than those with GT 1, 2, or 4, and the regional frequencies of HCV GT 2 and 3 ranged from 19.9% to 29.2%.
Anomalous Quantitation Standard Growth Curves in a Laboratory-Developed Hepatitis C Virus (HCV) RNA Quantification Assay Using the TaqMan HCV Analyte-Specific Reagent
Germer, Jeffrey J., Kathrotiya, Jemee D., Bouse, Carrie F., Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | May 7, 2009 | Volume: 47 | Issue: 7 | Pages: 2317-2320

10.1128/jcm.00028-09 Get It

ABSTRACT A retrospective examination of quantitation standard growth curves associated with 1,000 unique clinical serum specimens tested by a laboratory-developed TaqMan hepatitis C virus analyte-specific reagent-based assay revealed anomalous growth curves associated with 0.40% (95% confidence interval, 0.11% to 1.00%) of these specimens.
Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
Sloma, Cari R., Germer, Jeffrey J., Gerads, Tara M., Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | February 5, 2009 | Volume: 47 | Issue: 4 | Pages: 889-895

10.1128/jcm.02231-08 Get It

ABSTRACT The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results ( r = 0.95) among clinical specimens, with a mean difference of −0.34 log 10 copies/ml. Testing of healthy donor plasma specimens yielded “target not detected” results by ART, with “HIV-1 RNA detected, <40 copies/ml” results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively ( P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively ( P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.
Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on Clinical Laboratory Operations
Germer, Jeffrey J., Bendel, Jordan L., Dolenc, Craig A., Nelson, Sarah R., Masters, Amanda , Gerads, Tara M., Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | July 19, 2007 | Volume: 45 | Issue: 9 | Pages: 3101-3104

10.1128/jcm.00656-07 Get It

ABSTRACT The COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (CAP/CA), and the COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5, were compared. CAP/CA reduced and consolidated labor while modestly increasing assay throughput without increased failure rates or direct costs, regardless of batch size and assay format.
Quantification of Hepatitis B Virus (HBV) DNA with a TaqMan HBV Analyte-Specific Reagent following Sample Processing with the MagNA Pure LC Instrument
Germer, Jeffrey J., Qutub, Mohammed , Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | April 6, 2006 | Volume: 44 | Issue: 4 | Pages: 1490-1494

10.1128/jcm.44.4.1490-1494.2006 Get It

ABSTRACT TaqMan hepatitis B virus (HBV) analyte-specific reagent (ASR; Roche Molecular Systems, Inc., Branchburg, NJ) is designed for the quantification of HBV DNA in serum or plasma. The performance characteristics of TaqMan HBV ASR following automated sample processing with the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, IN) were evaluated in this study. Analytical sensitivity and precision were assessed with commercially available HBV standards, while clinical serum specimens from HBsAg-seropositive patients and healthy blood donors were used to determine clinical sensitivity, specificity, and correlation with other commercially available assays. Analytical studies yielded a limit of detection of 2.4 IU/ml, with good linearity and correlation ( R 2 = 0.9958) with expected HBV DNA titers over a wide range (6.0 × 10 0 to 2.1 × 10 8 IU/ml). Clinical sensitivity and specificity of the assay combined with automated sample processing were both 100%. Comparison of TaqMan HBV ASR and VERSANT HBV DNA 3.0 assay (bDNA; Bayer HealthCare LLC, Tarrytown, NY) results among clinical specimens yielded good correlation ( R 2 = 0.9237), with a mean difference in titer of −0.213 log 10 IU/ml (95% confidence interval, −0.678 to 1.10 log 10 IU/ml). The overall test failure rate was 2.0% among 204 clinical serum specimens tested. Total time required for MP sample processing and automated postelution handling of 24 samples was 224 min, with 57 min of actual hands-on time. MP is a reliable, labor-saving platform suitable for use with TaqMan HBV ASR, providing sensitive and accurate quantification of HBV DNA levels over a range of 8 log 10 IU/ml.
Evaluation of the Invader Assay for Genotyping Hepatitis C Virus
Germer, Jeffrey J., Yung, Billy, Mitchell, P. Shawn, Yao, Joseph D. , Majewski, David , Yung, Billy

Journal of Clinical Microbiology | February 2, 2006 | Volume: 44 | Issue: 2 | Pages: 318-323

10.1128/jcm.44.2.318-323.2006 Get It

ABSTRACT The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5′ noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, version 2.0; Roche Molecular Systems, Inc., Branchburg, NJ), COBAS AMPLICOR (COBAS AMPLICOR Hepatitis C Virus Test, version 2.0; Roche Molecular Systems, Inc.), and COBAS TaqMan (COBAS TaqMan HCV Test; Roche Molecular Systems, Inc.) assays. The minimum HCV RNA titers required for successful HCV genotyping (≥90% success rate) were 1,000 IU/ml for COBAS MONITOR, 100 IU/ml for COBAS AMPLICOR, and 10 IU/ml for COBAS TaqMan. Invader 1.0 results obtained from unpurified COBAS TaqMan amplification products of 111 retrospectively selected clinical serum specimens (genotypes 1 to 6, with virus titers ranging from 15.1 to 2.1 × 10 7 IU/ml) showed 98% concordance with results obtained from the TRUGENE HCV 5 ′ NC Genotyping Kit (Bayer HealthCare LLC, Tarrytown, NY), used in conjunction with COBAS AMPLICOR. Although the assay is sensitive, accurate, and easy to perform, additional optimization of the Invader 1.0 interpretive software (Invader Data Analysis Worksheet) may be necessary to reduce potential misidentification of HCV genotypes in low-titer specimens. In summary, Invader 1.0 is compatible with a variety of commercially available PCR-based HCV 5′ NC region amplification assays and is suitable for routine HCV genotyping in clinical laboratories.
Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC Instrument
Germer, Jeffrey J., Harmsen, William S. , Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | January 5, 2005 | Volume: 43 | Issue: 1 | Pages: 293-298

10.1128/jcm.43.1.293-298.2005 Get It

ABSTRACT The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteristics of TaqMan HCV following automated sample processing by the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, Ind.). The analytical sensitivity of TaqMan HCV following sample processing by MP was 8.1 IU/ml (95% confidence interval, 6.1 to 15.2). The assay showed good linearity ( R 2 = 0.99) across a wide range of HCV RNA levels (25 to 5 × 10 6 IU/ml), with coefficients of variation ranging from 10% to 46%. Among 83 clinical specimens, the sensitivity and specificity of TaqMan HCV were 100% and 95%, respectively, when compared to the COBAS AMPLICOR hepatitis C virus test, version 2.0 (COBAS AMPLICOR; Roche Molecular Systems), with TaqMan HCV detecting two more HCV RNA-positive specimens than COBAS AMPLICOR. Both specimens were confirmed to be HCV RNA positive by the VERSANT HCV RNA qualitative test (Bayer HealthCare LLC, Tarrytown, N.Y.). There was also strong correlation ( R 2 = 0.95) and good agreement between the results from TaqMan HCV and the VERSANT HCV RNA 3.0 assay (bDNA) (Bayer HealthCare LLC) among a group of 93 clinical specimens. The MP is a versatile, labor-saving sample processing platform suitable for reliable performance of TaqMan HCV.
Evaluation of the TRUGENE HCV 5′NC Genotyping Kit with the New GeneLibrarian Module 3.1.2 for Genotyping of Hepatitis C Virus from Clinical Specimens
Germer, Jeffrey J., Rosser, Michael, Thompson, Amber , Mitchell, P. Shawn, Smith, Thomas F., Elagin, Slava, Yao, Joseph D. , Majewski, David

Journal of Clinical Microbiology | August 5, 2004 | Volume: 42 | Issue: 8 | Pages: 3911-3911

10.1128/jcm.42.8.3911.2004 Get It

Evaluation of the TRUGENE HCV 5 ′ NC Genotyping Kit with the New GeneLibrarian Module 3.1.2 for Genotyping of Hepatitis C Virus from Clinical Specimens
Germer, Jeffrey J., Rosser, Michael, Thompson, Amber , Mitchell, P. Shawn, Smith, Thomas F., Elagin, Slava, Yao, Joseph D. , Majewski, David

Journal of Clinical Microbiology | October 7, 2003 | Volume: 41 | Issue: 10 | Pages: 4855-4857

10.1128/jcm.41.10.4855-4857.2003 Get It

ABSTRACT The TRUGENE HCV 5′NC genotyping kit (GeneLibrarian modules 3.1.1 and 3.1.2) and VERSANT HCV genotyping assay were compared by using 96 hepatitis C virus (HCV) RNA-positive patient specimens, including HCV genotypes 1, 2, 3, 4, 5, 6, and 10. The TRUGENE HCV 5 ′ NC genotyping kit (GeneLibrarian module 3.1.2) yielded the most accurate genotyping results.
Evaluation of the MagNA Pure LC Instrument for Extraction of Hepatitis C Virus RNA for the COBAS AMPLICOR Hepatitis C Virus Test, Version 2.0
Germer, Jeffrey J., Lins, Michele M., Jensen, Monica E., Harmsen, William S. , Ilstrup, Duane M., Mitchell, P. Shawn, Cockerill, Franklin R., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | August 6, 2003 | Volume: 41 | Issue: 8 | Pages: 3503-3508

10.1128/jcm.41.8.3503-3508.2003 Get It

ABSTRACT The COBAS AMPLICOR system has played a major role in the transition of molecular diagnostics from research to routine clinical laboratory use by automating the nucleic acid amplification and detection processes. However, sample preparation remains a labor-intensive portion of the procedure. In this study, we evaluated the performance of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 (Roche Molecular Systems, Branchburg, N.J.) following manual hepatitis C virus (HCV) RNA extraction versus automated extraction with the MagNA Pure LC instrument (Roche Applied Science, Indianapolis, Ind.). Parallel replicate testing was performed with standard dilutions of 100, 75, 60, and 0 HCV IU/ml and 153 clinical specimens. An analytical sensitivity of 75 IU/ml was achieved with either the manual or the standard-volume (200 μl) automated extraction methodologies (25 of 26 [96.2%]; 95% confidence interval [95% CI], 80.4 to 99.9), whereas the clinical sensitivity and specificity were both 100% with either extraction method. A large-volume (1 ml) automated extraction method was also evaluated with standard dilutions of 40, 25, 10, and 0 IU/ml and the same 153 clinical specimens. The analytical sensitivity of the COBAS AMPLICOR assay with the large-volume extraction method was 25 HCV IU/ml (26 of 26 [100%]; 95% CI, 86.8 to 100), whereas the clinical sensitivity and specificity were both 100%. The MagNA Pure LC instrument is a versatile, labor-saving platform capable of integration with minimal modification of the existing assay procedure. The increased sensitivity of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 performed in conjunction with large-volume HCV RNA extraction may be important in HCV diagnostic testing as new therapeutic strategies evolve.