Back to Authors

Lin, Wei‐Shao

https://orcid.org/0000-0002-4881-0569

Mayo Clinic

Indiana University Indianapolis

Citations 2

Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic review
Lin, Wei‐Shao , Eckert, Steven E

Clinical Oral Implants Research | October 17, 2018 | Volume: 29 | Issue: S16 | Pages: 78-105

10.1111/clr.13294 Get It

AbstractObjectivesThe aim of this review was to determine the clinical performance of dental implants that are intentionally tilted when compared with implants that are placed following the long axis of the residual alveolar ridge.Materials and methodsA systematic review of the scientific literature using a predefined research question (PICO) and search strategy was undertaken. This search included five electronic databases. Two independent reviewers examined electronic databases and performed a manual review following search strategy to accomplish the item generation and reduction. Included articles were evaluated to determine the level of evidence. Data were extracted only from level I and level II studies, based on the Oxford Centre for Evidence‐based Medicine—Levels of Evidence (March 2009). If included studies were homogeneous in nature, data were to be accumulated. However, if included studies were heterogeneous in nature, only descriptive data would be reviewed and analyzed.ResultsA total of 811 articles were identified through the PICO question and search strategy. Detailed review of the abstracts and articles resulted in further item reduction, and 46 articles were included for full‐text review. A total of 42 articles were then selected for inclusion in the systematic review. The identified articles included two level I and 20 level II studies. In addition, 15 level IV, one gray literature, and four previous systematic reviews with meta‐analyses were also used in the study. The extracted data from the included studies demonstrated heterogeneity that prevented quantitative assessment, and only one level II study directly compared tilted and axially placed implants. Assessment of the descriptive data demonstrated no differences in implant survival, marginal bone loss, prosthesis survival, or patient‐reported outcome measures (PROMs) whether implants are placed axially or with intentional inclination of the coronal aspect of the implant toward the distal aspect of edentulous jaws.ConclusionsBased upon the systematic review of the literature, an analysis of the descriptive data suggested no differences in clinical performance between implants that are placed in an axial position relative to the residual alveolar ridge when compared with implants that are intentionally tilted toward the distal aspect of edentulous jaws.
Group 2 ITI Consensus Report: Prosthodontics and implant dentistry
Morton, Dean , Gallucci, German O. , Lin, Wei‐Shao , Pjetursson, Bjarni E. , Polido, Waldemar D. , Roehling, Stefan , Aghaloo, Tara , Albera, Hugo, Bohner, Lauren , Braut, Vedrana, Buser, Daniel , Dawson, Anthony S. , Eckert, Steven E, Gahlert, Michael, Hamilton, Adam , Jaffin, Robert A., Jarry, Christian , Laine, Juhani, Martin, William , Rahman, Lira, Schlegel, Andreas, Shiota, Makato, Stilwell, Charlotte , Vorster, Christiaan, Zembic, Anja , Zhou, Wenjie , Eckert, Steven, Sailer, Irena , Chen, Stephen , Karayazgan, Banu , Rahman, Lira

Clinical Oral Implants Research | October 17, 2018 | Volume: 29 | Issue: S16 | Pages: 215-223

10.1111/clr.13298 Get It

Abstract Objectives Working Group 2 was convened to address topics relevant to prosthodontics and dental implants. Systematic reviews were developed according to focused questions addressing (a) the number of implants required to support fixed full‐arch restorations, (b) the influence of intentionally tilted implants compared to axial positioned implants when supporting fixed dental prostheses ( FDP s), (c) implant placement and loading protocols, (d) zirconia dental implants, (e) zirconia and metal ceramic implant supported single crowns and (f) zirconia and metal ceramic implant supported FDP s. Materials and methods Group 2 considered and discussed information gathered in six systematic reviews. Group participants discussed statements developed by the authors and developed consensus. The group developed and found consensus for clinical recommendations based on both the statements and the experience of the group. The consensus statements and clinical recommendations were presented to the plenary (gathering of all conference attendees) and discussed. Final versions were developed after consensus was reached. Results A total of 27 consensus statements were developed from the systematic reviews. Additionally, the group developed 24 clinical recommendations based on the combined expertise of the participants and the developed consensus statements. Conclusions The literature supports the use of various implant numbers to support full‐arch fixed prostheses. The use of intentionally tilted dental implants is indicated when appropriate conditions exist. Implant placement and loading protocols should be considered together when planning and treating patients. One‐piece zirconia dental implants can be recommended when appropriate clinical conditions exist although two‐piece zirconia implants should be used with caution as a result of insufficient data. Clinical performance of zirconia and metal ceramic single implant supported crowns is similar and each demonstrates significant, though different, complications. Zirconia ceramic FDP s are less reliable than metal ceramic. Implant supported monolithic zirconia prostheses may be a future option with more supporting evidence.