Objective Abnormalities are commonly identified during endoscopy in eosinophilic oesophagitis (EoE). There is no standardised classification to describe these features. This study aimed to evaluate the interobserver agreement of a grading system for the oesophageal features of EoE. Method The proposed system incorporated the grading of four major oesophageal features (rings, furrows, exudates, oedema) and the presence of additional features of narrow calibre oesophagus, feline oesophagus, stricture and crepe paper oesophagus. Endoscopic videos from 25 patients with EoE and controls were reviewed by 21 gastroenterologists. Interobserver agreement was assessed by estimating multi-rater κ and the proportion of pairwise agreement. Results Using the original grading system, agreement for rings, furrows and exudates was moderate (κ=0.38–0.46, 56–65% agreement) but poor for oedema (κ=0.23, 51% agreement). Identification of narrow calibre oesophagus had fair agreement (κ=0.30, 74% agreement) while feline oesophagus had poor agreement (κ=0.15, 68% agreement). After collapsing the severity grading for oedema and furrows and eliminating poorly performing features of feline oesophagus and narrow calibre oesophagus, a modified grading system demonstrated good agreement for the four major features of EoE (κ=0.40–0.54, 71–81% agreement) and additional features of stricture and crepe paper oesophagus (κ=0.52 and 0.58, 79% and 92% agreement). Conclusions The proposed system for endoscopically-identified oesophageal features of EoE defines common nomenclature and severity scores for the assessment of EoE disease activity. The system has good interobserver agreement among practising and academic gastroenterologists.
The Role of Preoperative Bilateral Breast Magnetic Resonance Imaging in Patient Selection for Partial Breast Irradiation in Ductal CarcinomaIn Situ
Purpose. Women with ductal carcinomain situ(DCIS) are often candidates for breast-conserving therapy, and one option for radiation treatment is partial breast irradiation (PBI). This study evaluates the use of preoperative breast magnetic resonance imaging (MRI) for PBI selection in DCIS patients.Methods. Between 2002 and 2009, 136 women with newly diagnosed DCIS underwent a preoperative bilateral breast MRI at Mayo Clinic in Florida. One hundred seventeen women were deemed eligible for PBI by the NSABP B-39 (National Surgical Adjuvant Breast and Bowel Project, Protocol B-39) inclusion criteria using physical examination, mammogram, and/or ultrasound. MRIs were reviewed for their impact on patient eligibility, and findings were pathologically confirmed.Results. Of the 117 patients, 23 (20%) were found ineligible because of pathologically proven MRI findings. MRI detected additional ipsilateral breast cancer in 21 (18%) patients. Of these women, 15 (13%) had more extensive disease than originally noted before MRI, and 6 (5%) had multicentric disease in the ipsilateral breast. In addition, contralateral breast cancer was detected in 4 (4%).Conclusions. Preoperative breast MRI altered the PBI recommendations for 20% of women. Bilateral breast MRI should be an integral part of the preoperative evaluation of all patients with DCIS being considered for PBI.
A Preliminary Study Comparing Attitudes toward Hospice Referral between African American and White American Primary Care Physicians
SUMMARYPre-pulse inhibition (PPI) of the acoustic startle reflex is deficient in patients with schizophrenia. This deficiency is mimicked in mice by the use of the psychotomimetic drugs d-amphetamine and dizolcipine. Antipsychotic drugs such as clozapine are used to treat schizophrenic patients and are also administered to mice to prevent PPI disruption. Neurotensin (NT) produces antipsychotic-like effects when injected into rodent brain through its effects at NT subtype 1 (NTS1) and 2 (NTS2) receptors. We hypothesized that the NT receptor agonist (NT69L) would prevent PPI disruption in mice challenged with d-amphetamine (10 mg kg–1) and dizocilpine (1 mg kg–1). We investigated the role of NTS1 and NTS2 in PPI using wild-type (WT), NTS1 (NTS1–/–) and NTS2 (NTS2–/–) knockout mice, via its disruption by psychotomimetic drugs, as well as the ability of clozapine and NT69L to block these PPI disruptions. There were no differences in baseline PPI across the three genotypes. d-Amphetamine and dizocilpine disrupted PPI in WT and NTS2–/– mice but not in NTS1–/– mice. In WT mice, clozapine (1 mg kg–1) and NT69L (1 mg kg–1) significantly blocked d-amphetamine-induced disruption of PPI. Similarly, in WT mice, clozapine significantly blocked dizocilpine-induced PPI disruption, but NT69L did not. In NTS2–/– mice clozapine blocked d-amphetamine-but not dizocilpine-induced PPI disruption, while NT69L blocked both d-amphetamine- and dizocilpine-induced PPI disruption. Our results indicate that NTS1 seems essential for d-amphetamine and dizocilpine disruption of PPI. Additionally, this report provides support to the hypothesis that NT analogs could be used as novel antipsychotic drugs.
Prevalence of Sodium Bicarbonate–Induced Alkalemia in Cardiopulmonary Arrest Patients
Background: Intravenous sodium bicarbonate (SB) administration during cardiopulmonary arrest (CPA) is intended to counteract lactic acidosis due to hypoxia, poor perfusion, and anaerobic metabolism. Despite a lack of documented efficacy and a level III recommendation from the American Heart Association, SB is widely used during resuscitation events. SB has both theoretical and measurable adverse effects. Excess or poorly timed administration during a CPA may elevate a patient's pH, inducing alkalemia. Despite decades of controversy surrounding use of this drug, the prevalence of SB-induced alkalemia has not been previously documented. Objective: To estimate the prevalence of SB-induced alkalemia in inpatients after CPA and to investigate the pattern of SB administration. Methods: Medical records were retrospectively reviewed with attention to SB administration and arterial blood gas (ABG) data. After application of inclusion and exclusion criteria to 264 CPA patients, the study group comprised 88 patients. When measured, il PCO 2 and pH were above normal limits after SB administration, we concluded that SB contributed to the alkalemia. Results: Twenty-seven (31 %) patients received SB without any ABG data, and 70 (79%) patients received at least one empiric SB dose. Of the 61 patients with ABG data, alkalemia occurred in 10, a prevalence of 16%. Administration of SB increased pH in only 9 (15%) other CPA patients and had no effect in the 42 (69%) remaining patients. Conclusions: Administration of SB during CPA was causally linked with inducing alkalemia in 16% of patients. Early collection of ABG samples may assist in optimizing pH during CPA and thus reduce unwarranted empiric use of SB.
Background Paraplegia is a devastating complication for patients undergoing repair of thoracoabdominal aortic aneurysms. A monitor to detect spinal cord ischemia is necessary if anesthesiologists are to intervene to protect the spinal cord during aortic aneurysm clamping. Methods The medical records of 60 patients who underwent thoracoabdominal aortic aneurysm repair with regional lumbar epidural cooling with evoked potential monitoring were reviewed. The authors analyzed latency and amplitude of motor evoked potentials, somatosensory evoked potentials, and H reflexes before cooling and clamping, after cooling and before clamping, during clamping, and after release of aortic cross clamp. Results Twenty minutes after the aortic cross clamp was placed, motor evoked potentials had 88% sensitivity and 65% specificity in predicting spinal cord ischemia. The negative predictive value of motor evoked potentials at 20 min after aortic cross clamping was 96%. Conclusions Rapid loss of motor evoked potentials or H reflexes after application of the aortic cross clamp identifies a subgroup of patients who are at high risk of developing spinal cord ischemia and in whom aggressive anesthetic and surgical interventions may be justified.
Cardiac dose evaluation for 3Dimensional conformal partial breast irradiation compared with whole breast irradiation
To compare the radiation dose to normal cardiac tissue for 3Dimensional (3D) conformal external beam partial breast irradiation (PBI) and standard whole breast irradiation (WBI), and examine the effect of tumor bed location.For 14 patients with left breast tumors randomized on the National Surgical Adjuvant Breast and Bowel Project B‐39 protocol, computer‐generated radiotherapy treatment plans were devised for WBI and PBI. Tumor bed location was designated according to whether more than 50% of the excision cavity was medial or lateral to the nipple line. The volume of heart receiving doses of 2.5, 5, 10, and 20 Gy was calculated for all PBI and WBI plans. Dose to 5% of the heart volume (D5) and mean heart dose were also calculated. The biologically‐equivalent dose (BED) was calculated to account for the different fractionation used in PBI and WBI.Of the 14 patients, 8 had lateral tumor beds, and 6 had medial tumor beds. The volumes of heart receiving 2.5, 5, 10, and 20 Gy were significantly lower for lateral PBI compared with WBI. For medial PBI, significant cardiac sparing was only seen at a dose of 20 Gy. The difference of D5 values was significant for lateral PBI compared with WBI , but not for medial PBI compared with WBI . The mean dose was also significantly lower for lateral PBI compared with WBI , but not for medial PBI . The results from BED calculations did not change this outcome.Both 3D conformal PBI and standard WBI can deliver relatively low doses to the heart. For patients with lateralized tumor beds, PBI offers significant cardiac sparing compared with WBI. Patients with medial lesions have relatively similar heart dosimetry with PBI and WBI. 3D conformal PBI is an emerging treatment modality and continued participation on clinical trials is encouraged. Patients with left‐sided lesions and lateralized tumor beds warrant special consideration for PBI, given the significant cardiac dose sparing.PACS numbers: 87.53.Tf
Analysis of allergy alerts within a computerized prescriber-order-entry system