Précis: Designed with novel features to facilitate implantation and improve safety, the Ahmed ClearPath (ACP) glaucoma drainage device (GDD) provided intraocular pressure (IOP) reduction comparable with other GDDs in eyes with refractory glaucoma in a multicenter retrospective study. Purpose: To present clinical outcomes with a novel valveless GDD (ACP, New World Medical). The 250 and 350 mm2 models feature a contoured plate for optimal globe apposition, anteriorized suture points to facilitate suturing to the globe, and a prethreaded 4-0 polypropylene ripcord suture. Methods: This was a multicenter retrospective analysis of eyes with medically and/or surgically uncontrolled glaucoma implanted with the 250 or 350 mm2 ACP either as a standalone procedure or in combination with other procedures. Pre-, intra-, and postoperative data through 6 months were collected. Results: A total of 104 eyes (100 subjects) received the ACP by 10 US surgeons, 63.5% of which had primary open-angle glaucoma and 62.5% had severe glaucoma. Mean baseline IOP was 26.3 (9.0) mm Hg and mean medication use was 3.9 (1.3). Through 6 months’ follow-up, mean IOP ranged from 13.6 to 16.7 mm Hg and mean medication use from 0.9 to 1.9 medications (P<0.0001 at all timepoints for each outcome measure). At 6 months, mean IOP was 13.7 mm Hg (−13.0 mm Hg, 43.0%, P<0.0001) and mean medication use was 1.9 medications per eye (−2.1, 47.7%, P<0.0001). Common adverse events included anterior chamber inflammation (16.3%), hyphema (15.4%), and hypotony (6.7%). Conclusion: The new ACP appears to be safe and efficacious as a standalone procedure or in combination with other procedures for uncontrolled glaucoma, and may be considered as a GDD option for patients in whom its unique design may facilitate the implantation process.
Response: Goniotomy Using the Kahook Dual Blade in Severe and Refractory Glaucoma: 6-Month Outcomes
Purpose: The purpose of the study is to describe short-term efficacy and safety of goniotomy with trabecular meshwork excision using the Kahook Dual Blade (KDB, New World Medical Inc., Rancho Cucamonga, CA) in patients with severe or refractory glaucoma. Method: Retrospective multicentric case series of 53 eyes with severe or refractory glaucoma as defined by ICD-10 conducted in the United States, Mexico, and Switzerland. Primary efficacy outcome was a ≥20% decrease in intraocular pressure (IOP) from baseline at 6 months. Secondary efficacy outcome measures were probability of achieving an IOP≤14 or 18 mm Hg at 6 months and the mean IOP change from baseline at 6 months. Medication use required to obtain target IOP at last follow up and adverse effects were analyzed. Results: The proportion of eyes achieving an IOP reduction of >20% from preoperative baseline at 6 months was 57.7% (n=30). The mean IOP decreased from 18.4±6.1 mm Hg at baseline to 13.9±3.5 mm Hg at month 6 (23.9% reduction; P<0.001). At 6 months, 63.5% and 92.3% achieved an IOP≤14 and ≤18 mm Hg, respectively, and the mean number of glaucoma medications was reduced by 1.2±1.3 (36.6%) compared with baseline (P<0.001). The most common adverse event was hyphema (n=29, 34.9%) with spontaneous resolution in all cases. No severe complications were reported. One case presented with uncontrolled IOP and required glaucoma drainage device surgery at 1 month. Conclusions: Goniotomy with trabecular meshwork excision using the KDB could be an alternative surgery for severe or refractory glaucoma, significantly reducing IOP and medication use at 6 months, with a low rate of complications.