Abstract Background Artificial intelligence (AI)-based polyp detection systems are used during colonoscopy with the aim of increasing lesion detection and improving colonoscopy quality. Patients and methods: We performed a systematic review and meta-analysis of prospective trials to determine the value of AI-based polyp detection systems for detection of polyps and colorectal cancer. We performed systematic searches in MEDLINE, EMBASE, and Cochrane CENTRAL. Independent reviewers screened studies and assessed eligibility, certainty of evidence, and risk of bias. We compared colonoscopy with and without AI by calculating relative and absolute risks and mean differences for detection of polyps, adenomas, and colorectal cancer. Results Five randomized trials were eligible for analysis. Colonoscopy with AI increased adenoma detection rates (ADRs) and polyp detection rates (PDRs) compared to colonoscopy without AI (values given with 95 %CI). ADR with AI was 29.6 % (22.2 % – 37.0 %) versus 19.3 % (12.7 % – 25.9 %) without AI; relative risk (RR] 1.52 (1.31 – 1.77), with high certainty. PDR was 45.4 % (41.1 % – 49.8 %) with AI versus 30.6 % (26.5 % – 34.6 %) without AI; RR 1.48 (1.37 – 1.60), with high certainty. There was no difference in detection of advanced adenomas (mean advanced adenomas per colonoscopy 0.03 for each group, high certainty). Mean adenomas detected per colonoscopy was higher for small adenomas (≤ 5 mm) for AI versus non-AI (mean difference 0.15 [0.12 – 0.18]), but not for larger adenomas (> 5 – ≤ 10 mm, mean difference 0.03 [0.01 – 0.05]; > 10 mm, mean difference 0.01 [0.00 – 0.02]; high certainty). Data on cancer are unavailable. Conclusions AI-based polyp detection systems during colonoscopy increase detection of small nonadvanced adenomas and polyps, but not of advanced adenomas.
Adenoma recurrence after endoscopic mucosal resection: propensity score analysis of old and new colonoscopes and Sydney recurrence tool implementation
Abstract Background and study aims Risk factors for colorectal adenoma recurrence after endoscopic mucosal resection (EMR) have been well documented. We assessed the efficacy of the newer 190 colonoscope versus the standard 180 colonoscope for complete resection of lateral spreading lesions. Patients and methods A single-center, retrospective study of patients who underwent EMR with Olympus 180 or 190 colonoscopes from January 1, 2010 to September 30, 2016. We included patients with lesions ≥ 20 mm and surveillance colonoscopy (SC1) after index EMR. A propensity score approach with inverse probability weighting was used to control for potential confounders. A secondary aim was to identify risk factors for recurrence and assess the applicability of the Sydney EMR recurrence tool (SERT) by grading each lesion of our cohort and analyzing associations with recurrence. Results Two hundred ninety-one lesions met inclusion criteria for the study. Odds ratio (OR) for recurrence with the 190 colonoscope was 1.06 (P = .85). Adenoma size (P = .02) and use of argon plasma coagulation (APC; P < .001) were risk factors for recurrence. Lesions with SERT scores > 0 had a higher recurrence risk during follow-up (32 % vs 21 %; OR 1.71; P = .05). Lesions with SERT scores = 0 reached a plateau for recurrence at 12 and 18 months in Kaplan-Meier curves. Conclusions The use of 190 colonoscopes did not measurably affect adenoma recurrence at SC1. Recurrence was associated with adenoma size, complementary APC for resection, and SERT scores > 0. Lesions with SERT scores = 0 that remain negative for recurrence at 18 months may return to routine surveillance.