Back to Authors

Edwards, A. W. T.

Mayo Clinic

Mayo Clinic

Citations 3

Use of an optical density ruler in measurements of dye-dilution curves
Bassingthwaighte, James B. , Edwards, A. W. T., Wood, Earl H.

Journal of Applied Physiology | December 24, 2017 | Volume: 19 | Issue: 2 | Pages: 347-353

10.1152/jappl.1964.19.2.347 Get It

The inapplicability of Beer's law to densitometry of dyes in whole blood or other nonhomogeneous media has been long known. When using a densitometer whose output is directly proportional to the light transmitted, a simple transformation— log X = log (x – x0)—can be employed to allow rapid, accurate estimation of dye concentration. This is facilitated by use of an optical density ruler. The transformation, X = x – x0, can be made mechanically, by shifting the infinity position of the ruler with reference to the zero light transmission position, or electrically, by appropriate use of zero suppression in the densitometer circuit. The transformation results in an exponential (logarithmic) relationship between light transmitted and concentration of the dye (indocyanine green). Readings of relative optical density obtained by use of the ruler are multiplied by a calibration constant to calculate dye concentration. The principles of the transformation have been applied to the determination of the optimal zero suppression required for maintenance of constant sensitivity of the densitometer in the presence of various levels of background dye. densitometer calibration; indocyanine green densitometer; calibration of dye-dilution curves; correction of dye-dilution curves Submitted on September 13, 1963
Areas of dye-dilution curves sampled simultaneously from central and peripheral sites
Bassingthwaighte, James B. , Edwards, A. W. T., Wood, Earl H.

Journal of Applied Physiology | December 24, 2017 | Volume: 17 | Issue: 1 | Pages: 91-98

10.1152/jappl.1962.17.1.91 Get It

The assumption that the rate of blood flow past the sampling site is constant is basic to the Stewart-Hamilton estimation of cardiac output. Pulsatile flow might be expected to cause random and systematic errors. In this study dye-dilution curves were recorded simultaneously from two or three sites (pulmonary artery, aortic root, thoracic aorta, femoral artery) after injections of dye into the inferior vena cava, right ventricle, pulmonary artery, or left atrium of anesthetized dogs. The color of the indocyanine-protein complex formed after injection of the dye stabilized rapidly. Such stabilization is required for continuous photometric quantitation of dilution curves with juxtaposed injection and sampling sites. Areas of curves from the central circulation did not differ significantly from each other; they averaged 2.5% less than areas of curves recorded simultaneously from the femoral artery. Heart rate had no consistent influence. The large variability in estimates of cardiac output from curves recorded from the pulmonary artery after injection into the right ventricle was diminished with injection farther upstream. Submitted on May 29, 1961
Indocyanine green densitometry in flowing blood compensated for background dye
Edwards, A. W. T., Isaacson, J. R., Sutterer, William F., Bassingthwaighte, James B. , Wood, Earl H.

Journal of Applied Physiology | December 24, 2017 | Volume: 18 | Issue: 6 | Pages: 1294-1304

10.1152/jappl.1963.18.6.1294 Get It

Blood is nonhomogeneous; hence, the relationship between light transmission and increasing concentration of dye in whole blood is never the perfect exponential curve predicted by Beer's law. Instead, as the concentration of indocyanine green is increased to high levels (40 mg/liter) the light transmission decreases exponentially toward an asymptote at 6–8% transmission for nearly monochromatic densitometers (half-band width: 13–20 mμ), but at 30–40% for densitometers using light of wide-band width. Consequently, following recording of a dilution curve, circulating background dye reduces the change in transmission per unit increase in dye concentration in subsequent curves. This decrease in sensitivity cannot be compensated for by a simple increase in the sensitivity of the densitometer or in the intensity of its light source. Compensation can be attained, however, if increasing densitometer sensitivity is associated with the automatic scale expansion provided when a suppressed zero point is used. At correct zero suppression, the deflection for zero output of the densitometer coincides with the asymptotic transmission value mentioned above. indicator-dilution in circulation; blood flow measurement; blood optical density; dye dilution technic; cardiac output measurement Submitted on April 15, 1963