Back to Authors

Pruthi, Rajiv K.

https://orcid.org/0000-0002-6969-929X

Mayo Clinic

Mayo Clinic

Citations 181

The Contribution of Corn Trypsin Inhibitor on Thrombin Generation Kinetics in Trauma Patients: A Comparative Analysis
Navarro, Sergio M. , Thompson, Riley J., Spears, Grant M. , Bailey, Kent R. , Dong, Jing-fei, Kozar, Rosemary A. , Pruthi, Rajiv K. , Park, Myung S., Navarro, Sergio Michael , Chen, Dong

Blood | December 5, 2024 | Volume: 144 | Issue: Supplement 1 | Pages: 5529-5529

10.1182/blood-2024-201035 Get It

Trauma-induced coagulopathy (TIC) is common after injury and reliable quantification of its severity is lacking. The objective of this study was to evaluate whether thrombin generation would be significantly altered if whole blood samples from trauma patients were collected without (citrate-only) and with corn trypsin inhibitor (CTI+). In a prospective cohort study, 36 trauma pts presenting to a Level I Trauma Center within 12 hours of injury, had whole blood collected simultaneously in citrate-only (3.2%) and citrated plus CTI (CTI+ [final 25 ug/mL]), and processed to platelet free plasma by double centrifugation (3000g, 15 minutes). Samples were stored at -80C with no thawing until analysis. Thrombin generation profiles were measured using the ST Genesia assay (Diagnostica STAGO SAS) and parameters included endogenous thrombin potential (ETP), lag time (LT), peak height, start of tail, velocity index, and time to peak (ttPeak) were analyzed for trauma pts. Data presented as median [IQR] or n (%), with paired t-test and Spearman's correlation analysis were performed between citrated non-CTI and citrated CTI spiked blood samples, with p-value <0.05 statistically significant. Pts presented with significant injury ISS 13 [5, 21], age 45 [29, 59] years, 80.6% male, BMI 26.9 [25.4, 28.3], 94.4% blunt trauma, 22.3% had surgery by day 1 of admission. Significant differences were found between the citrated-only and CTI +tubes in several thrombin generation parameters: ETP (1339 Nm*min [1172.5,1417], 1124.5 [925.4,1285], p<0.001), peak height (222.3 Nm [186.0, 275.6], 160.6 [132.7,208.3], p<0.001), ttPeak (5.64 min [4.86,6.63], 6.19 [5.36, 7.34], p<0.001), start of tail (19.4 min [17.6,21.3], 21.6 [18.9, 23.6], p=0.014), and velocity index (117.6 Nm/min [77.9, 163.1], 71.9 [54.9,106.0], p<0.001). However, LT (3.14 min [2.74, 3.90], 3.08 [2.84, 3.96], p=0.665) did not show a statistically significant difference. Spearman's correlation analysis showed high correlation between citrate-only and CTI+ citrated plasma samples, with Spearman's rank correlation coefficients for LT (0.941), peak height (0.760), ttPeak (0.928), ETP (0.770), start of tail (0.869), and velocity index (0.766) respectively. The results suggest that use of CTI+ decrease thrombin generation kinetics from blood samples obtained from trauma patients. These findings underscore the need for careful consideration of sample collection and processing for use of thrombin generation assays in clinical setting. However, there is very strong correlation of the thrombin parameters obtained from citrated-only plasma to CTI+ plasma samples, suggesting they capture similar information. CTI-spiked citrated tubes appear to reduce contact activation with respect to thrombin generation profiles compared to standard citrated only tubes. This should be a consideration for platform-based lab processing of thrombin generation assays for assessment of coagulopathy after injury; however, given the cost of CTI, citrated-only tubes can be an option for characterization of thrombin generation profile in clinical samples.
Highlighting Success: Asian Minority Representation in the Hematology-Oncology Workforce
Go, Lewis T , Go, Lucas T, Gunaratne, M, Ashrani, Aneel A. , Elliott, Michelle A. , Hook, C. Christopher , Padrnos, Leslie , Pruthi, Rajiv K. , Rivera, Candido E., Rouse, Rachelle, Shah, Surbhi , Shaikh, Marwan , Wysokinska, Ewa , Abeykoon, Jithma P. , Godby, Richard , Siddiqui, Mustaqeem , Sridharan, Meera , Wolanskyj, Alexandra P. , Go, Ronald S.

Blood | December 5, 2024 | Volume: 144 | Issue: Supplement 1 | Pages: 7946-7946

10.1182/blood-2024-199887 Get It

Background The American Society of Clinical Oncology (ASCO) launched the Diversity in Oncology initiative in 2017 to address the need for increased minority representation in the hematology-oncology workforce. A recent series of reports, titled “State of the Oncology Workforce in America,” published in JCO Oncology Practice in 2021 and 2022, focused on this issue. Notably, these reports did not include any data regarding the representation of Asian minorities in the field. Therefore, our objective was to assess the proportion of Asian professionals within the hematology-oncology workforce, encompassing both practitioners and trainees. Methods We conducted a comprehensive search for publicly available data regarding Asian representation among US hematology-oncology practitioners and trainees in both adult and pediatric fields. Our primary data sources included the 2020 US Census, the Association of American Medical Colleges, the Accreditation Council for Graduate Medical Education, and various professional societies. We defined practitioners to include hematologist-oncologists, gynecologic oncologists, radiation oncologists, surgical oncologists, hematopathologists, hematology-oncology nurse practitioners, hematology-oncology physician assistants, and nurses specializing in hematology-oncology. Trainees encompassed fellows and residents. Additionally, we gathered comparable data on the US population, medical students, adult internal medicine residents, gynecology residents, pediatric residents, pathology residents, surgery residents, nurses, nurse practitioners, and physician assistants. To provide a comprehensive overview of the hematology-oncology workforce, we utilized data from 2020 to 2022, and whenever possible, we collected longitudinal data on trainees over the years. Results As of 2020, Asians represented 6.2% of the US population. Among hematology-oncology physician practitioners, the percentage of Asian individuals ranges from 14.7% to 32.1%, including 32.1% of adult hematologist-oncologists, 20.4% of pediatric hematologist-oncologists, 25.9% of radiation oncologists, 14.7% of gynecologic oncologists, and 7.0% of hematology-oncology physician assistants. In the realm of physician trainees, Asian representation is between 17.9% and 35.3%, with 35.3% of adult hematology-oncology fellows, 20.0% of pediatric hematology-oncology fellows, 26.4% of radiation oncology residents, and 17.9% of gynecologic oncology fellows. Additionally, the proportion of Asian residents from which hematology-oncology fellows are drawn ranges from 14.9% to 35.9%. Specifically, 35.9% of internal medicine residents, 22.0% of pediatric residents, 14.9% of gynecology residents, 26.6% of pathology residents, and 19.2% of surgical residents are Asian. Furthermore, 26.7% of medical students identify as Asian. Notably, the proportions of Asian hematology-oncology trainees and medical students have remained relatively stable from 2005 to 2022. Data on hematopathologists, surgical oncologists, and non-physician practitioners are limited, although Asian representation among hematology-oncology physician assistants is 7.0% and among nurses is 7.2%. Conclusions Asians comprise a large segment of the hematology-oncology workforce in the US. While only 1 in 20 people in the US are Asians, between 1 in 3 and 1 in 5 hematology-oncology physician practitioners and trainees, are Asians. Data are limited for non-physician practitioners. Asian minority representation should be highlighted and considered as an example of success in diversity in hematology-oncology workforce. This framework should be embraced moving forward to continue advancing minority representation throughout the field of hematology-oncology.
Conformation-specific RNA aptamers for phenotypic distinction between normal von Willebrand factor and type 2B von Willebrand disease
Machha, Venkata R. , Moon‐Tasson, Laurie, Tange, Julie I, Santiago-Davis, Annyoceli, Pruthi, Rajiv K. , Chen, Dong , Maher, L. James , Auton, Matthew , Tischer, Alexander , Moon-Tasson, Laurie, Tange, Julie, Chen, Dong , III, Louis James Maher , Auton, Matthew , Tischer, Alexander

NAR Molecular Medicine | November 24, 2024 | Volume: 1 | Issue: 4 | Pages: No page available

10.1093/narmme/ugae021 Get It

Abstract The A1 domain in Von Willebrand Factor (VWF) initiates coagulation through binding to platelet glycoprotein GPIbα receptors. Von Willebrand Disease (VWD)-Mutations in A1 that either impair (type 2M) or enhance (type 2B) platelet adhesion to VWF can locally destabilize and even misfold the domain. We leveraged misfolding in the gain-of-function type 2B VWD phenotype as a target, distinct from the normal conformation. Two nuclease-resistant 2′-fluoropyrimidine RNA aptamers were selected to discriminate normal A1 domains from a type 2B V1314D A1 variant in a glycosylated A1A2A3 tri-domain VWF-fragment. Two aptamers, W9 and V1, were isolated that selectively recognize, bind, and inhibit the A1–GPIbα interaction with WT A1A2A3 and V1314D A1A2A3, respectively. These aptamers were tested against their respective recombinant targets, plasma VWF, VWF concentrates, and patient plasma with the heterozygous type 2B VWD R1306W variant using clinical assays, surface plasmon resonance and inhibition assays of platelet adhesion to recombinant A1 and A1A2A3 domains under shear stress. The specificity of W9 and V1 aptamers confirms that pathological conformations of VWD Type 2B proteins are different from normal VWF. The availability of aptamers that distinguish normal plasma-derived VWF from VWD suggests potential applicability in clinical diagnosis of severe gain-of-function phenotypes.
A-144 Liquid chromatography multiple reaction monitoring-based assay for quantitative assessment of fibrinogen levels in clinical samples
Bokka, Ramesh, Venkataraman, Shreyas , Peterson, Jane A., Tange, Julie I, Leger, Rachel, Seheult, Jansen N. , Pruthi, Rajiv K. , Seheult, Jansen N , Chavan, Sandip , Venkataraman, S, Peterson, J, Chen, Dong , Pandey, Akhilesh

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.142 Get It

Abstract Background Fibrinogen plays a critical role in hemostasis and is essential to clot formation. Changes in the quantity or activity of fibrinogen can lead to disorders affecting coagulation. Thus, it is essential to precisely quantify fibrinogen levels to differentiate between hyperfibrinogenemia in hypercoagulable disorders and dysfibrinogenemia, hypo/afibrinogenemia, and irregular bleeding. Current diagnostic tests that use antibodies to detect fibrinogen or activity-based measures are susceptible to interference from heparin contamination, hemolysis, and hyperbilirubinemia. Here, we evaluated the use of targeted proteomics for developing a quantitative assay for fibrinogen in plasma samples. Methods Four peptides each for alpha and gamma chains of fibrinogen were synthesized using FMOC chemistry on a Liberty Blue (CEM Corp) peptide synthesizer. A targeted multiple reaction monitoring (MRM) assay was developed and optimized using Dionex Ultimate 3000 HPLC connected to a TSQ Altis triple quadrupole mass spectrometer (Thermo Scientific). Evaluations were conducted using a range of standards, such as pure protein, WHO plasma and commercially available plasma with known fibrinogen amounts for the accurate quantitation of fibrinogen. Calibration curves were generated using different dilutions in various matrices. The repeatability and precision of the assay were evaluated across five different days. The plasma samples were processed and digested in a 96-well plate and subjected to C18 clean-up using a Bravo automated liquid handler (Agilent). All samples were spiked-in with corresponding heavy-labeled peptides prior to digestion with trypsin. Multiple reaction monitoring assays were performed on tryptic digests of plasma samples. Results Calibration curves using commercial plasma for all peptides showed linearity from 20 mg/dl to 1,308 mg/dl. This covers the entire clinical range including normal (200-350 mg/dl), deficient states (<100 mg/dl) and excess production (>350 mg/dl) that can be used for evaluation of bleeding disorders including consumption coagulopathy and hyperfibrinogenemia. Based on the overall performance in terms of linearity, limit of detection/quantitation, carryover and coefficient of variation (CV) across five different days, two peptides per chain were finally selected for developing the quantitative assay. The intra-assay variability was <5% and intra-day CV was ∼20%. This assay is currently being tested on a variety of clinical samples representing a range of fibrinogen levels. Conclusions Our study focused on assessing whether multiplexed MRM assay could be implemented to measure fibrinogen levels in plasma. Our data indicate the feasibility of MRM-based assays for determining fibrinogen levels as an alternative to existing non-mass spectrometry-based activity or antigen assays.
A-161 Diagnosis of Lupus Anticoagulant Cases using Deep Neural Networks
Leger, Rachel, Heikal, Nahla, Pruthi, Rajiv K. , Wang, J, Chen, Dong , Seheult, Jansen N.

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.159 Get It

Abstract Background Laboratory identification of lupus anticoagulant (LAC) is critical for diagnosing antiphospholipid antibody syndrome, a common cause of unprovoked thromboembolic events and pregnancy morbidity. Commonly used clot-based assays for LAC include the dilute Russell’s viper venom time (DRVVT) and activated partial thromboplastin time (APTT), but these are susceptible to anticoagulant interferences. Despite standardization efforts, LAC interpretation remains challenging due to pre- and post-analytical complexity and limited expertise. This study explored the use of deep neural networks (DNN) to facilitate LAC diagnosis. Methods Retrospective data for LAC profiling with 13 features performed at Mayo Clinic between 2021 and 2022 was collected. The profiles of 7,202 patients were randomly divided into training (n=4608), validation (n=1153), and test cohorts (n=1441). Diagnostic outputs including LAC positivity (determined by DRVVT or APTT) and the presence of warfarin (WAR) and heparin (HEP), were confirmed by expert assessment. Three DNN architectures were developed and evaluated (Figure 1): (1) four single output DNN models with a domain knowledge driven selection of input features, (2) four single output DNN models using the same 13 inputs across all models, and (3) a multi-output DNN model. Model performance was evaluated using the F1 score and the index of balanced accuracy (IBA) for each output label. Results Architecture 1 achieved high diagnostic accuracy with IBA values of 0.989-1.000 for all four outputs and F1 scores of 0.945-0.991. Architecture 2 exhibited F1 scores of 0.902-0.973 and IBA values of 0.935-0.992. Architecture 3 achieved F1 scores of 0.933-0.967 and IBA values of 0.941-0.983. Conclusions All three architectures accurately classify LAC and common anticoagulation effects. The comparable performance of architectures 1 and 2 suggests that manual feature extraction is unnecessary. Given its relative simplicity and versatility, architecture 3 is the preferred choice for implementation in a clinical laboratory to standardize LAC diagnosis.
Transplacental transfer of emicizumab: Experience with emicizumab in a pregnant female with severe hemophilia A and an inhibitor
Kharel, Zeni , Pruthi, Rajiv K. , Reid, Robin, Kouides, Peter A. , Reid, Robin

Haemophilia | April 23, 2024 | Volume: 30 | Issue: 3 | Pages: 868-871

10.1111/hae.15022 Get It

C3+ and C3− warm autoimmune hemolytic anemias: A comparison of clinical characteristics and treatment outcomes
Nunnelee, Jordan , Abeykoon, Jithma P. , Ashrani, Aneel A. , Elliott, Michelle A. , Hook, C. Christopher , Pardanani, Animesh , Pruthi, Rajiv K. , Rouse, Rachelle, Sridharan, Meera , Abeykoon, Jithma Prasad, Elliott, Michelle Ann, Rouse, Rachelle L, Sridharan, Meera , Wolanskyj, Alexandra P. , Go, Ronald S.

European Journal of Haematology | April 16, 2024 | Volume: 113 | Issue: 1 | Pages: 132-134

10.1111/ejh.14212 Get It

Use of crushed tranexamic acid tablets in water for paediatric patients with bleeding disorders
Al‐Huniti, Ahmad , Marshall, Linda, Rusk, Dawn, Pruthi, Rajiv K. , Rodriguez, Vilmarie , Ferdjallah, Asmaa , Kuhn, Alexis

Haemophilia | March 20, 2024 | Volume: 30 | Issue: 3 | Pages: 648-657

10.1111/hae.14996 Get It

AbstractBackgroundΕ‐Aminocaproic acid oral solution (EACA OS) is the only commercially available antifibrinolytic for patients who cannot swallow tablets. Insurance denials and high costs remain barriers to its use.ObjectivesTo determine the safety and efficacy of crushed tranexamic acid tablets in water (cTXAw) for children with bleeding disorders.MethodsWe retrospectively reviewed records of children (<10 years) with bleeding disorders who received cTXAw or EACA OS from 1 December 2018, through 31 July 2022, at Mayo Clinic (Rochester, Minnesota). Bleeding outcomes were defined according to ISTH criteria.ResultsThirty‐two patients were included (median age, 3 years; male, n = 23). Diagnoses were VWD (n = 17), haemophilia (n = 5), FVII deficiency (n = 3), inherited platelet disorder (n = 4), ITP (n = 2), and combined FV and FVII deficiencies (n = 1). Thirty‐two courses of cTXAw (monotherapy 24/32; mean duration 6 days) and fifteen courses of EACA (monotherapy 12/15; mean duration 5 days) were administered. No surgical procedures (n = 28) were complicated by bleeding. Of the 19 bleeding events, 16 had effective haemostasis, two had no reported outcome, and one had no response. cTXAw and EACA were equally effective in preventing and treating bleeding (p value > .1). No patients had adverse effects. Eight of 19 patients (42%) who were initially prescribed EACA OS did not receive it because of cost or insurance denial.The estimated average wholesale price of one treatment was $94 for cTXAw and $905 for EACA OS.ConclusionsCTXAw appears to be an effective, safe, and low‐cost alternative option to EACA OS for young children with bleeding disorders.
The lupus anticoagulant titer is associated with elevated antiphosphatidylserine/prothrombin immunoglobulin‐M isotype antibody levels
Chen, Dong , Stuart, Melissa K. , Pruthi, Rajiv K. , Heikal, Nahla, Snyder, Melissa R. , Ashrani, Aneel A. , Seheult, Jansen N. , Chen, Dong , Stuart, Melissa, Pruthi, Rajiv K , Ashrani, Aneel, Seheult, Jansen, Seheult, Jansen N , Saadalla, Abdulrahman

International Journal of Laboratory Hematology | February 21, 2024 | Volume: 46 | Issue: 4 | Pages: 695-704

10.1111/ijlh.14251 Get It

AbstractBackgroundClot based assays used for lupus anticoagulant (LAC) detection are typically interpreted in a qualitative fashion and may not reflect LAC potency. In this cross‐sectional study, we describe a method for quantifying the LAC titer using serial (dependent) two‐fold dilutions in normal pooled plasma.MethodsSerial dilutions of 51 residual plasma samples from 50 patients were tested using the Russell's viper venom screening time (DRVVT) and activated partial thromboplastin screening time (APTT) methodologies. The measured clotting times and the corresponding dilution factors were then used to derive a four‐parameter logistic model. The LAC titer for each patient was interpolated as the sample dilution that corresponds to the upper reference interval limit of the corresponding assay.ResultsCalculated APTT and DRVVT LAC titers displayed a strong linear correlation (R2 = 0.84) between each other, but not with the degree of prolongation of the APTT/DRVVT screening time in the neat undiluted samples. Using data driven partitioning, patients could be grouped into low (<10) or high (≥10) DRVVT LAC titer. There were no significant differences in anticardiolipin (aCL) or anti‐beta 2 glycoprotein 1 (aB2GPI) antibody levels or prevalence of thromboembolic events between low and high LAC titer groups. In contrast, antiphosphatidylserine/prothrombin (aPS/PT) IgM antibody levels, but not IgG, were significantly higher in the high LAC titer group.ConclusionsThe degree of prolongation of the APTT/DRVVT screening time is not correlated with the LAC titer. Only aPS/PT IgM antibodies levels were strongly correlated with the LAC titers. Additional studies are warranted to determine clinical implications of high LAC titers.
Postgraduate Institute of India (PGI) textbook of laboratory and clinical hematology. By Koyamangalath Krishnan (Ed.), Mumbai, India: Bhalani Publishing House. 2024. pp. 3244. ISBN: 9789381496763
Pruthi, Rajiv K.

American Journal of Hematology | February 13, 2024 | Volume: 99 | Issue: 4 | Pages: 800-800

10.1002/ajh.27235 Get It