Increasing interest is focusing on the role of intestinal tone, distensibility, and mechanosensation in the genesis of abdominal symptoms. Experimental approaches usually feature balloon distension of the bowel with measurements of perception, tone, and compliance and/or elastance; however, the methodologies are standardized incompletely. We examined the reproducibility of repeated assessments of sensory perception, basal tone, and compliance and/or elastance of the rectum during distension. We also evaluated the response to inflations that varied in regard to control of pressure or volume, pattern of distension, and rate of inflation. Five healthy volunteers were studied under two separate protocols. The first featured a series of experiments on each of 5 days; the other consisted of 2 separate days of study. Repeated distensions evoked reproducible responses of sensation and compliance and/or elastance on a single day, providing a conditioning distension preceded them. Day-to-day variability was also sufficiently small to allow valid comparisons to be made on different days in healthy persons. The configuration of the distension profile (phasic, staircase, or ramp) and the rate of inflation (from 1 to 40 ml/s) had little effect on distensibility or perception. Perceptions were sometimes transient and sometimes constant, but no relationship was found between these temporal features and the magnitude of the stimulus. These observations help provide a basis as to how the responses to rectal distension can be best studied.
Variations in muscle tone of the human rectum: recordings with an electromechanical barostat
Rectal wall tone (the contractile state of the rectal tunica muscularis) should mediate accommodation and influence rectal emptying. Such changes in tone however can be only inferred from changes in baseline pressure recorded with conventional manometry. We used an isobaric volumetric device, the rectal electromechanical barostat, to quantify variations in tone of the rectal wall in response to feeding and to perturbations in response to the pharmacological agents neostigmine and glucagon. The barostat quantitates muscular wall tone indirectly by measuring its reciprocal, e.g., the volume of air within a flaccid intraluminal bag that is maintained at a constant and preselected pressure, by an electronic feedback mechanism. The barostat as well as a three-channel perfused manometric catheter were positioned in the rectum of 14 healthy volunteers. Three patterns of changes were observed: 1) respiratory fluctuations, 2) rapid volume waves, and 3) slow volume changes. Rectal tone varied little during fasting; rapid or slow changes in intrabag volume were infrequent. Ingestion of a standard meal was followed by a significant decrease in barostat bag volume (85 +/- 6 ml fasting vs. 50 +/- 8 ml fed, P less than 0.05). Pharmacological agents also induced predictable responses; neostigmine decreased bag volume and induced phasic pressure activity, whereas glucagon abolished phasic pressure activity and increased barostat bag volume. Perfused manometric catheters showed no concomitant changes in baseline pressure. We concluded that a rectal barostat measured variations in human rectal tone, which were not recorded by conventional manometric techniques. These changes in rectal tone might have important functional significance.