Back to Authors

Fülesdi, Béla

https://orcid.org/0000-0003-2541-9740

Mayo Clinic

University of Debrecen

Citations 12

Hand Size Measurements in Children Aged 1–15 Years to Help the Development of Pediatric Electromyography Sensors for Neuromuscular Monitoring
Nemes, Réka, Németh, Erzsébet, Szatmári, Katalin, Timkó, Adrienn, Luterán, Péter, Brull, Sorin J. , Fülesdi, Béla , Pongrácz, Adrienn , Brull, Sorin J , Németh, Erzsébet

Journal of Clinical Medicine | October 23, 2025 | Volume: 14 | Issue: 21 | Pages: 7462

10.3390/jcm14217462 Get It

Background/Objectives: The aim of this observational study was to collect hand measurements and anthropometric data in children aged 1–15 years of age to help the design of a pediatric skin electrode for electromyography-based neuromuscular monitoring. Methods: Data collection was performed at the Pediatric Department of the University of Debrecen Medical Centre between 1 December 2019 and 31 January 2021. After gaining written informed consent from the parents or legal representatives and verbal acceptance from age-appropriate (12–35 months) patients, a total of 153 children were enrolled. The following parameters were recorded: demographics (age, sex, weight, height, and hand dominance) and hand size parameters, defined as the distance between the following reference points: the ulnar groove and the midpoint of the hypothenar eminence (A); the midpoint of the hypothenar eminence and the first interphalangeal joint of the 5th finger (B); the ulnar groove and the midpoint of the thenar eminence (C); the midpoint of the thenar eminence and the interphalangeal joint of the thumb (D); the midpoint of the wrist crease and the tip of the third finger; wrist circumference (E); and forearm length. All measurements were made in centimeters (cm). Results: The children were divided into 4 groups (12–23 months, 2–5 years, 6–11 years and 12+ years). The number of children in the groups ranged between 6 and 16. The hand size parameters increased according to the children’s age (A: 4.3 ± 0.4, 5.0 ± 0.7, 6.3 ± 0.6, and 6.9 ± 1.0 cm; B: 3.2 ± 0.4, 4.1 ± 0.7, 5.0 ± 0.6, and 5.9 ± 0.6 cm; C: 3.0 ± 0.3, 3.6 ± 0.7, 4.1 ± 0.6, and 4.9 ± 0.6 cm; D: 4.1 ± 0.4, 4.8 ± 0.8, 6.2 ± 0.8, and 7.2 ± 0.9 cm; E: 10.1 ± 0.6, 12.0 ± 1.1, 15.3 ± 1.3, and 17.7 ± 1.7 cm, respectively, in the four groups, [mean ± SD]). The height of the children showed a closer correlation with hand size parameters (Pearson’s correlation coefficients: 0.702–0.961) than with age (0.665–0.904) or weight (0.675–0.863). The correlation was weaker when data were examined in prespecified age groups. Conclusions: The current pediatric hand size database provides previously unavailable information that was used in one manufacturer’s design, which may help with the future design of pediatric electrodes of electromyography-based neuromuscular monitors; this information may facilitate adoption of quantitative neuromuscular monitoring in routine pediatric anesthesia practice.
Time Course of a Single, 0.6 mg/kg Dose of Rocuronium Neuromuscular Block During Sevoflurane or Propofol Anesthesia in Infants—A Prospective, Randomized Trial
Fülesdi, Béla , Luterán, Péter, Boktor, Mena, Asztalos, László , Nagy, György M., Brull, Sorin J. , Molnar, C. J. , Molnár, Csilla , Brull, Sorin J , Nagy, György

Journal of Clinical Medicine | September 15, 2025 | Volume: 14 | Issue: 18 | Pages: 6459

10.3390/jcm14186459 Get It

Background: There is little data available in infants on the extent to which inhalational anesthetics prolong the effects of neuromuscular blocking agents compared with intravenous agents. Here, we assessed the differences between the neuromuscular blocking effects (duration and recovery time) of a single dose of rocuronium during propofol vs. sevoflurane anesthesia. Methods: The prospective study enrolled 20 infants (4–12 months of age) scheduled for craniosynostosis surgery, randomly assigned to receive general anesthesia maintenance with sevoflurane or propofol. All patients received 0.6 mg/kg rocuronium as a single bolus dose to facilitate tracheal intubation and surgery. Primary study endpoint was the clinical duration of rocuronium, from administration until spontaneous recovery to a train-of-four ratio (TOFR) > 0.90. Secondary endpoints were times for reappearance of the first, second, third, and fourth twitches of the TOF (T1, T2, T3 and T4, respectively) in the two patient groups. Results: There were no differences in the infants’ age (sevoflurane maintenance: 5.8 ± 2.4 months; propofol maintenance: 6.7 ± 3.1 months, p = 0.47) or weight (sevoflurane: 7722 ± 1644 g; propofol: 7433 ± 1782 g, p = 0.71). Rocuronium onset time was 101.0 ± 55.0 s in the sevoflurane group and 83.4 ± 47.9 s in the propofol group (p = 0.46). Total duration of anesthesia was comparable in the sevoflurane (122.0 ± 23.8 min) and propofol (107.7 ± 25.2 min, p = 0.18) groups. Rocuronium recovery to TOFR > 0.9 required 136 min (CI: 123.7–149.5 min) in the sevoflurane group and 61.5 min (CI: 58.0–101.0 min) in the propofol group (p < 0.001). Conclusions: In infants, sevoflurane maintenance enhances the neuromuscular blocking effect of a single, 0.6 mg/kg BW dose of rocuronium as compared to propofol maintenance. After discontinuation of sevoflurane, additional time is necessary to reach the acceptable TOFR >0.9 needed before tracheal extubation. The present study further underscores the importance of objective (quantitative) neuromuscular monitoring in infants to guide intraoperative management and prevent residual neuromuscular block.
The Relationship Between Neuromuscular Block Depth and Airway Retroglossal Area: A Prospective, Nonrandomized, Observational Clinical Trial
Asztalos, László , Boktor, Mena, Kukuly, Miklós, Sólyom, Dorka, Pongrácz, Adrienn , Brull, Sorin J. , Fülesdi, Béla , Brull, Sorin J

Journal of Clinical Medicine | June 19, 2025 | Volume: 14 | Issue: 12 | Pages: 4374

10.3390/jcm14124374 Get It

Background: Tracheal intubation and mechanical ventilation are facilitated by neuromuscular blocking agents. We investigated the effectiveness of subjective clinical evaluation of neuromuscular function on retroglossal area size, since it determines spontaneous ventilation adequacy following tracheal extubation. Secondarily, we correlated changes in retroglossal area and depth of neuromuscular block assessed during both respiratory phases using quantitative neuromuscular monitoring. Methods: Once mechanical ventilation was no longer needed, antagonists were used to reverse the neuromuscular block in 21 consenting patients; adequacy of reversal was assessed subjectively by delivering a sequence of four rapid (2 Hz) electrical stimuli (train-of-four, TOF) to a peripheral nerve and assessing attainment of four equal muscle contractions (TOF ratio = 1.0), signifying normal neuromuscular function. Retroglossal area during both inhalation and exhalation were measured pharyngoscopically at various phases of neuromuscular recovery, including at baseline after anesthesia induction but before neuromuscular block onset and at recovery before tracheal extubation; area changes were correlated with depth of quantitatively measured neuromuscular block. Results: Clinicians’ subjective evaluation of readiness for tracheal extubation failed to identify significant residual block in most patients who required rescue antagonism. Markedly decreased retroglossal areas (inhalation: 39.5% of baseline; exhalation: 20.1% of baseline) were present at extubation, and 11 out of 21 (52.4%) patients needed rescue antagonism. In contrast, in patients with neuromuscular recovery to the currently recommended threshold determined quantitatively (TOF ratio > 0.90), retroglossal areas were only 80% recovered but returned to near baseline values when the TOF ratio ≥ 0.95. Conclusions: Quantitative monitoring should guide the timing of tracheal extubation. Current definitions of the minimal threshold for adequate neuromuscular recovery (TOF ratio > 0.90) after mechanical ventilation in postoperative patients should be re-evaluated. A TOF ratio > 0.95 better correlates with return to normal (baseline) retroglossal area during both inhalation and exhalation.
Good clinical research practice (GCRP) in pharmacodynamic studies of neuromuscular blocking agents III: The 2023 Geneva revision
Fuchs‐Buder, Thomas , Brull, Sorin J. , Murphy, Glenn S. , Warlé, Michiel C. , Nemes, Réka, Damian, Daniela , Iwasaki, Hajime , Eriksson, Lars I., Brull, Sorin J , Fagerlund, Malin Jonsson , Renew, J. Ross , Cammu, Guy , Vested, Matias , Fülesdi, Béla , Columb, Malachy O. , Davis, Peter J.

Acta Anaesthesiologica Scandinavica | June 24, 2023 | Volume: 67 | Issue: 8 | Pages: 994-1017

10.1111/aas.14279 Get It

AbstractThe set of guidelines for good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents was developed following an international consensus conference in Copenhagen in 1996 (Viby‐Mogensen et al., Acta Anaesthesiol Scand 1996, 40, 59–74); the guidelines were later revised and updated following the second consensus conference in Stockholm in 2005 (Fuchs‐Buder et al., Acta Anaesthesiol Scand 2007, 51, 789–808). In view of new devices and further development of monitoring technologies that emerged since then, (e.g., electromyography, three‐dimensional acceleromyography, kinemyography) as well as novel compounds (e.g., sugammadex) a review and update of these recommendations became necessary. The intent of these revised guidelines is to continue to help clinical researchers to conduct high‐quality work and advance the field by enhancing the standards, consistency, and comparability of clinical studies.There is growing awareness of the importance of consensus‐based reporting standards in clinical trials and observational studies. Such global initiatives are necessary in order to minimize heterogeneous and inadequate data reporting and to improve clarity and comparability between different studies and study cohorts. Variations in definitions of endpoints or outcome variables can introduce confusion and difficulties in interpretation of data, but more importantly, it may preclude building of an adequate body of evidence to achieve reliable conclusions and recommendations. Clinical research in neuromuscular pharmacology and physiology is no exception.
Quantitative Neuromuscular Monitoring: “Love All, Trust a Few, Do Wrong to None”
Brull, Sorin J. , Brull, Sorin J , Fülesdi, Béla

Anesthesia & Analgesia | June 16, 2022 | Volume: 135 | Issue: 1 | Pages: 35-38

10.1213/ane.0000000000006035 Get It

Ipsilateral and Simultaneous Comparison of Responses from Acceleromyography- and Electromyography-based Neuromuscular Monitors
Nemes, Réka, Nagy, György M., Hampton, David R., Gray, Martyn, Brull, Sorin J. , Brull, Sorin J , Lengyel, Szabolcs, Nagy, György, Renew, J. Ross , TASSONYI, Edömer , Fülesdi, Béla

Anesthesiology | July 30, 2021 | Volume: 135 | Issue: 4 | Pages: 597-611

10.1097/aln.0000000000003896 Get It

Background The paucity of easy-to-use, reliable objective neuromuscular monitors is an obstacle to universal adoption of routine neuromuscular monitoring. Electromyography (EMG) has been proposed as the optimal neuromuscular monitoring technology since it addresses several acceleromyography limitations. This clinical study compared simultaneous neuromuscular responses recorded from induction of neuromuscular block until recovery using the acceleromyography-based TOF-Watch SX and EMG-based TetraGraph. Methods Fifty consenting patients participated. The acceleromyography and EMG devices analyzed simultaneous contractions (acceleromyography) and muscle action potentials (EMG) from the adductor pollicis muscle by synchronization via fiber optic cable link. Bland–Altman analysis described the agreement between devices during distinct phases of neuromuscular block. The primary endpoint was agreement of acceleromyography- and EMG-derived normalized train-of-four ratios greater than or equal to 80%. Secondary endpoints were agreement in the recovery train-of-four ratio range less than 80% and agreement of baseline train-of-four ratios between the devices. Results Acceleromyography showed normalized train-of-four ratio greater than or equal to 80% earlier than EMG. When acceleromyography showed train-of-four ratio greater than or equal to 80% (n = 2,929), the bias was 1.3 toward acceleromyography (limits of agreement, –14.0 to 16.6). When EMG showed train-of-four ratio greater than or equal to 80% (n = 2,284), the bias was –0.5 toward EMG (–14.7 to 13.6). In the acceleromyography range train-of-four ratio less than 80% (n = 2,802), the bias was 2.1 (–16.1 to 20.2), and in the EMG range train-of-four ratio less than 80% (n = 3,447), it was 2.6 (–14.4 to 19.6). Baseline train-of-four ratios were higher and more variable with acceleromyography than with EMG. Conclusions Bias was lower than in previous studies. Limits of agreement were wider than expected because acceleromyography readings varied more than EMG both at baseline and during recovery. The EMG-based monitor had higher precision and greater repeatability than acceleromyography. This difference between monitors was even greater when EMG data were compared to raw (nonnormalized) acceleromyography measurements. The EMG monitor is a better indicator of adequate recovery from neuromuscular block and readiness for safe tracheal extubation than the acceleromyography monitor. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
In Response
Prielipp, Richard C., Brull, Sorin J. , Brull, Sorin J , Fülesdi, Béla

Anesthesia & Analgesia | March 15, 2021 | Volume: 132 | Issue: 4 | Pages: e61-e63

10.1213/ane.0000000000005414 Get It

Postoperative Opioid-Induced Respiratory Depression: 3 Steps Forward
Prielipp, Richard C., Brull, Sorin J. , Brull, Sorin J , Fülesdi, Béla

Anesthesia & Analgesia | September 13, 2020 | Volume: 131 | Issue: 4 | Pages: 1007-1011

10.1213/ane.0000000000005098 Get It

Heuristics, Overconfidence, and Experience With Management of Neuromuscular Block: Self-Correction Is Unlikely
Naguib, Mohamed, Brull, Sorin J. , Hunter, Jennifer M. , Kopman, Aaron F., Johnson, Ken B. , Arkes, Hal R. , Naguib, Mohamed , Fülesdi, Béla , Brull, Sorin J

Anesthesia & Analgesia | September 2, 2019 | Volume: 129 | Issue: 5 | Pages: e172-e173

10.1213/ane.0000000000004377 Get It

Awake Volunteer Pain Scores During Neuromuscular Monitoring
Nemes, Réka, Nagy, György M., Murphy, Glenn S. , Logvinov, Ilana I. , Nagy, György, Fülesdi, Béla , Renew, J. Ross , Logvinov, Ilana

Anesthesia & Analgesia | July 26, 2019 | Volume: 130 | Issue: 4 | Pages: 941-948

10.1213/ane.0000000000004326 Get It

BACKGROUND: There is a need for easy to use, reliable neuromuscular monitors (NMMs). This multicenter, prospective, unblinded study compared the discomfort associated with neurostimulation in unmedicated healthy volunteers when using the new electromyography (EMG)-based TetraGraph and acceleromyography (AMG)-based TOF-Watch NMMs. The secondary aim was to compare the repeatability of the train-of-four (TOF) ratios (TOFRs) obtained with the 2 devices. METHODS: The TOF measurements of 135 volunteers from 3 university hospitals were analyzed (age: 38.3 ± 12 years [mean ± standard deviation [SD]]; male/female ratio = 63:72). The left or right ulnar nerve was stimulated at the wrist in TOF mode with 20, 30, 40, and 50 mA stimulating current intensities with both devices in random order. The TOF-Watch used standard electrocardiography (ECG) electrodes (Red Dot; 3M Health Care) for nerve stimulation. The stimulating surface area of 1 ECG electrode is 113 mm 2 . The piezoelectric probe was attached to the thumb, and a hand adapter was used to ensure consistency of AMG measurements. The TetraGraph uses proprietary surface strip electrodes for nerve stimulation and muscle action potential recording, whose stimulating surface area is roughly twice as big as that of standard ECG electrodes (228.5 mm 2 ). The volunteers were asked to rate the discomfort associated with neurostimulation on a 0–10 verbal numerical rating scale (VNRS) score anchored with 0 (no pain) and 10 (worst pain ever experienced). A linear mixed-effects model was used to evaluate the difference in VNRS scores between devices. P <.05 was accepted as the level of significance. RESULTS: In the linear mixed-effects model, there were no differences in VNRS scores between devices at any of the stimulating current intensities, P = .38. The median (range) VNRS scores obtained with TOF-Watch and TetraGraph devices were 2 (0–7) vs 2 (0–8) at 20 mA, 3 (1–9) vs 3 (1–9) at 30 mA, 5 (1–10) vs 5 (1–10) at 40 mA, and 5 (1–10) vs 6 (1–10) at 50 mA stimulating current intensities. The mean of the 1469 TOFRs obtained with TetraGraph was 100.43% ± 7.74% (standard error = 0.2%). Due to technical difficulties, the repeatability of the TOFRs could not be determined. CONCLUSIONS: Despite the different size and design of the stimulating electrodes, the 2 NMMs caused the same level of discomfort in unmedicated healthy volunteers.