Thrombus organization in canine carotid arteries occluded with platinum microcoils was studied to determine if endothelial injury created with a Xenon Chloride Excimer Laser (XEL) could acclerate endovascular fibrosis. Ten common carotid artery stumps were created in ten dogs. Each of four stumps were schematically divided into four longitudinally contiguous injury zones (thermal ablation injury, non-ablative injury, proximal and distal non-injury zones) to test the effects of ablative and non-ablative injury and to establish a set of internal controls that would account for proximity to circulating blood at the ostium of the occluded artery. Following XEL irradiation of the endothelium through an arteriotomy, each stump was embolized with microcoils. Four control stumps were subjected to sham laser procedures, and embolized in an identical fashion. Two additional stumps were embolized in the absence of sham surgery. Angiographic, gross and histologic analysis was performed after four weeks. Specimens of freshly clotted whole blood mixed with microcoils were used as an additional control. In irradiated stumps and non-irradiated stumps (sham and embolization only), angiography revealed no evidence of coil compaction or recanalization. In all irradiated stumps the thermal ablation zone contained fibrous tissue and neovascularity without unorganized thrombus. The other zones in the irradiated stumps were indistingnishable from each other and from all zones in the non-irradiated sham stumps, containing primarily unorganized thrombus. Stumps embolized in the absence of sham surgery were filled with material that was grossly and microscopically identical to specimens of freshly clotted whole blood containing microcoils. The results indicate that thermal ablation injury of the endothelium accelerates thrombus organization in canine carotid arteries occluded with platinum microcoils.
The fate of cranial neuropathy after flow diversion for carotid aneurysms
OBJECT The authors sought to determine whether flow diversion with the Pipeline Embolization Device (PED) can approximate microsurgical decompression in restoring function after cranial neuropathy following carotid artery aneurysms. METHODS This multiinstitutional retrospective study involved 45 patients treated with PED across the United States. All patients included presented between November 2009 and October 2013 with cranial neuropathy (cranial nerves [CNs] II, III, IV, and VI) due to intracranial aneurysm. Outcome analysis included clinical and procedural variables at the time of treatment as well as at the latest clinical and radiographic follow-up. RESULTS Twenty-six aneurysms (57.8%) were located in the cavernous segment, while 6 (13.3%) were in the clinoid segment, and 13 (28.9%) were in the ophthalmic segment of the internal carotid artery. The average aneurysm size was 18.6 mm (range 4–35 mm), and the average number of flow diverters placed per patient was 1.2. Thirty-eight patients had available information regarding duration of cranial neuropathy prior to treatment. Eleven patients (28.9%) were treated within 1 month of symptom onset, while 27 (71.1%) were treated after 1 month of symptoms. The overall rate of cranial neuropathy improvement for all patients was 66.7%. The CN deficits resolved in 19 patients (42.2%), improved in 11 (24.4%), were unchanged in 14 (31.1%), and worsened in 1 (2.2%). Overtime, the rate of cranial neuropathy improvement was 33.3% (15/45), 68.8% (22/32), and 81.0% (17/21) at less than 6, 6, and 12 months, respectively. At last follow-up, 60% of patients in the isolated CN II group had improvement, while in the CN III, IV, or VI group, 85.7% had improved. Moreover, 100% (11/11) of patients experienced improvement if they were treated within 1 month of symptom onset, whereas 44.4% (12/27) experienced improvement if they treated after 1 month of symptom onset; 70.4% (19/27) of those with partial deficits improved compared with 30% (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality.
Removal of An Orbital Metallic Foreign Body to Facilitate Magnetic Resonance Imaging: Technical Case Report
Abstract OBJECTIVE AND IMPORTANCE: Magnetic resonance imaging (MRI) is the imaging modality of choice for brain tumors and other lesions of the central nervous system. However, this procedure is contraindicated in patients with orbital metallic foreign bodies. In such cases, the usual clinical strategy is to manage the patient without the benefit of MRI scans and, instead, to rely on less sensitive imaging modalities in particular computed tomographic scanning. CLINICAL PRESENTATION: Two patients, one with a posterior fossa mass and one with suspected central nervous system lymphoma, were seen at our institution. MRI scanning was recommended, but had been precluded in both patients by the presence of metal fragments in the orbit. INTERVENTION: In each case, the orbital foreign body was successfully localized and removed. Postprocedure computed tomographic scanning confirmed complete removal. MRI scanning was then performed without difficulty. The first patient underwent posterior fossa craniotomy and removal of the tumor, which proved to be a medulloblastoma. The second patient was found to have evidence of lymphoma in the cranial base and meninges and was treated with radiotherapy and systemic and intrathecal chemotherapy. MRI scanning provided superior diagnostic information and spared both patients the risks and discomfort of myelography and exposure to ionizing radiation from multiple computerized tomographic scans. CONCLUSION: Two patients with central nervous system tumors underwent removal of a metal fragment in the orbit for the specific purpose of facilitating MRI scans. This is a practical, straightforward concept, which should be considered when MRI scanning is needed for optimal patient management.