AbstractIntroductionSacral tumor resection is known for a high rate of complications. Sarcopenia has been found to be associated with wound complications; however, there is a paucity of data examining the impact of sarcopenia on the outcome of sacral tumor resection.MethodsForty‐eight patients (31 primary sarcomas, 17 locally recurrent carcinomas) undergoing sacrectomy were reviewed. Central sarcopenia was assessed by measuring the psoas:lumbar vertebra index (PLVI), with the 50th percentile (0.97) used to determine which patients were high (>0.97) versus low (<0.97).ResultsTwenty‐four (50%) patients had a high PLVI and 24 (50%) had a low PLVI (sarcopenic). There was no difference (p > 0.05) in the demographics of patients with or without sarcopenia. There was no difference in the incidence of postoperative wound complications (odds ratio [OR] = 1.0, p = 1.0) or deep infection (OR = 0.83, p = 1.0). Sarcopenia was not associated with death due to disease (hazard ratio [HR] = 2.04, p = 0.20) or metastatic disease (HR = 2.47, p = 0.17), but was associated with local recurrence (HR = 6.60, p = 0.01).ConclusionsCentral sarcopenia was not predictive of wound complications or infection following sacral tumor resection. Sarcopenia was, however, an independent risk factor for local tumor recurrence following sacrectomy and should be considered when counseling patients on the outcome of sacrectomy.
Comparison of all‐polyethylene and metal‐backed modular tibial components in endoprosthetic reconstruction of the distal femur
AbstractIntroductionAll‐polyethylene (AP) tibial components have demonstrated equivalent or improved long‐term survivorship and reduced cost compared with metal‐backed (MB) components in primary total knee arthroplasty; however, there is a lack of data comparing these outcomes in the setting of an oncologic endoprosthetic reconstruction.MethodsA total of 115 (88 AP:27 MB) patients undergoing cemented distal femur endoprosthetic reconstruction following oncologic resection were reviewed. Mean age was 40 years and 51% were females. Cumulative incidences of all‐cause revision, tibial component revision, reoperation, and infection were calculated utilizing a competing risk analysis with death as the competitor. Mean follow‐up was 14 years.ResultsThe 10‐year cumulative incidence of all‐cause revision was 19.9% in the AP group and 16.3% in the MB group (hazard ratio [HR] = 0.93, p = 0.88). The cumulative incidence of tibial component revision was significantly lower in AP compared with MB at 10 years (1.1% vs. 12.5%, HR = 0.18, p = 0.03). There was no difference in infection‐free survival when comparing the two groups (p = 0.72).ConclusionsReconstruction utilizing an MB or AP tibia component resulted in equivalent overall outcome; however, the tibial component in the AP group was less likely to be revised. AP tibial component should be considered for all primary oncologic reconstructions in the distal femur.Level of EvidenceLevel III Therapeutic.
Modern Surgical Treatment of Recurrent Posterior Dislocation of the Native Hip
Background: Redislocation of the native hip is rare. An anterior fulcrum between the proximal part of the femur and the pelvis must be present for a posterior dislocation to occur. The purpose of this study is to describe the cases of 9 patients with posterior redislocation or recurrent subluxation of the native hip that was treated with hip preservation surgery. Methods: We retrospectively identified the cases of 9 patients, from 2 institutions, who had undergone hip preservation surgery for the management of posterior redislocation or recurrent subluxation of the native hip after a dislocation. The mean number of dislocations prior to surgery was 3.2 (range, 1 to 7). Pelvic radiographs were used to classify the acetabular morphology, sufficiency of acetabular containment, and structural anatomy of the proximal part of the femur. Radiographic identification of impinging structures was used to guide surgical treatment, which involved either femoral correction alone or the combination of femoral correction and an anteverting periacetabular osteotomy. Results: At a mean follow-up of 73.8 months (range, 10 to 192 months), there had been no subsequent episodes of dislocation or subluxation in any of the hips treated with correction of the anatomic pivot point. An algorithmic approach is presented. Conclusions: In patients who have episodes of redislocation or recurrent subluxation of the native hip, the identification of anatomic abnormalities that create a fulcrum between the proximal part of the femur and the pelvis is critical for making appropriate treatment decisions. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Patellar Tendon Repair With Ipsilateral Semitendinosus Autograft Augmentation
Abstract Patellar tendon ruptures are rare but potentially devastating injuries. Acute repair after patellar tendon rupture affords the best opportunity for tension‐free restoration of the extensor mechanism. Biological augmentation of primary repair is believed to decrease strain across the repair site and reduce the risk of rerupture. We present a technique for primary patellar tendon repair with bidirectional fixation using transosseous tunnels, suture anchor fixation, and ipsilateral hamstring autograft augmentation in a distal patellar pole socket. Technique Video video See video under supplementary data.
Horizontal Cleavage Meniscus Tear Treated With All‐inside Circumferential Compression Stitches
Abstract Horizontal cleavage meniscus tears are a common orthopedic injury often treated with partial or total meniscectomy versus repair. This Technical Note presents a technique for all‐inside repair with uniform compression of the superior and inferior leaflets by placement of multiple circumferential compression stitches using an all‐inside self‐retrieving suture passing device. The currently described technique provides several advantages for all‐inside repair of a horizontal cleavage tear: (1) eliminates the need for a posterior incision, (2) minimizes the risk of neurovascular injury, (3) uses standard arthroscopy portals (or small modifications), and (4) requires only a single suture deployment with a self‐retrieving device for each circumferential compression stitch. The resulting circumferential stitch provides uniform compression to the superior and inferior leaflets, promoting meniscal healing. This configuration has been shown to have the highest load to failure of all repair patterns. Technique Video video See video under supplementary data.
Surgical Treatment of Pediatric Upper Limb Spasticity: The Shoulder