Background: Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Methods: Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. Results: The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm 2 to 150 ± 58 mm 2 (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). Conclusions: The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. Clinical Relevance: This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.
Viability of Periosteal Tissue Obtained Postmortem
Periosteal autografts have the potential to regenerate articular cartilage defects, but this potential is limited by the patient's age. Allograft transplantation from a young donor to an older recipient might bypass this limitation. The effect of the time delay, between death and harvesting of a periosteal graft, on the chondrogenic potential of periosteum is important not only for transplantation but also for studies dealing with tissues retrieved postmortem (i.e., including the periosteal explant model). The purpose of this study was to investigate the chondrogenic potential of periosteum obtained postmortem and a possible beneficial effect of hypothermia. Thirty NZ white rabbits (2 months old) were sacrificed and stored at room temperature or 4°C for 0, 4, 6, 8, 12, 16, 18, or 24 h. Periosteal explants were then obtained and a standard cartilage yield assay performed by culturing them for 6 weeks using the periosteal organ culture model as previous published. TGF-β1 (10 ng/ml) was added for the first 14 days of culture. Histochemical analysis and quantitative collagen typing were performed. In the explants from the animals kept for 4 h at room temperature growth and chondrogenesis were dramatically reduced. Little or no chondrogenesis was seen in expiants from rabbits maintained at room temperature after 4–8 h (or more) postmortem. Cooling the rabbits to 4°C partially prevented this loss of viability and continued to do so for 24 h. Even storage at 4°C did not eliminate the decrease in chondrogenic potential, though it did permit partial preservation of chondrogenic potential. If periosteum is to be used for allograft transplantation, or if it is used for experimental study, its viability must be assured. This is best accomplished by harvesting it immediately postmortem. Preservation techniques, cryopreservation, or hypothermia might be useful in preserving periosteal chondrogenic potential.
Porous tantalum biocomposites for osteochondral defect repair
ObjectivesWe sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling.Materials and MethodsAdult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically.ResultsAt 16 weeks post-operatively, histological scores amongst treatment groups were not statistically different (TMPG: overall 12.7, cartilage 8.6, bone 4.1; TM: overall 14.2, cartilage 9.5, bone 4.9; ED: overall 13.6, cartilage 9.1, bone 4.5). Metal scaffolds were incorporated into the surrounding bone, both in TM and TMPG. The sGAG yield was lower in the neo-cartilage regions compared with the articular cartilage (AC) controls (TMPG 20.8/AC 39.5, TM 25.6/AC 33.3, ED 32.2/AC 40.2 µg sGAG/1 mg respectively), with statistical significance being achieved for the TMPG group (p < 0.05). Hypercellularity of the neo-cartilage was found in TM and ED, as the dsDNA content was significantly higher (p < 0.05) compared with contralateral AC controls (TM 126.7/AC 71.1, ED 99.3/AC 62.8 ng dsDNA/1 mg). The highest type II collagen content was found in neo-cartilage after TM compared with TMPG and ED (TM 60%/TMPG 40%/ED 39%). Inter-treatment differences were not significant.ConclusionsTM is a highly suitable material for the reconstitution of osseous defects. TM enables excellent bony ingrowth and fast integration. However, combined with autologous periosteum, such a biocomposite failed to promote satisfactory neo-cartilage formation. Cite this article: E. H. Mrosek, H-W. Chung, J. S. Fitzsimmons, S. W. O’Driscoll, G. G. Reinholz, J. C. Schagemann. Porous tantalum biocomposites for osteochondral defect repair: A follow-up study in a sheep model. Bone Joint J 2016;5:403–411. DOI: 10.1302/2046-3758.59.BJR-2016-0070.R1.
Accuracy and inter‐observer reliability of visual estimation compared to clinical goniometry of the elbow
AbstractPurposeTo test the hypothesis that visual estimation by a trained observer is as accurate and reliable as clinical goniometry for measuring elbow range of motion.MethodsInstrument validity and inter‐observer reliability of visual estimation was evaluated on a consecutive series of 50 elbow contractures. Four observers with different levels of elbow experience first estimated extension and flexion of the contracted elbows and then measured them with a blinded goniometer.ResultsInstrument validity for visually‐based goniometry was extremely high. ICC scores were 0.97 for both extension and flexion estimations. Systematic error was negligible (1°) with upper limits of agreement being 9° (95% CI: 7°–11°) and 8° (95% CI: 6°–10°), respectively, for extension and flexion. For the expert surgeon, 92% of the visual estimates were within 5° of the value obtained by clinical goniometry. Between experienced observers (elbow surgeon and physician assistant), the ICC’s were very high—0.96 for extension and 0.93 for flexion. The systematic errors were low, from −1° to 1° with upper limit of agreement being 11° (95% CI: 8°–14°). However, agreement was poor between an inexperienced study coordinator and the others (ICC’s: 0.51–0.38, systematic errors: 8°–18°, upper limit of agreement: 32°–40°). The accuracy of the visual estimations made by the experienced elbow surgeon was as good as the measurements taken with a goniometer by the physician assistant or the clinical fellow and better than those taken by an inexperienced study coordinator.ConclusionsThe trained human eye is highly capable of accurately estimating the range of motion of the elbow, compared to conventional clinical goniometry, depending on the experience of the observer.Level of evidenceDiagnostic study, Level II.
Arthroscopic removal of the failed silicone radial head prosthesis
AbstractAlthough silicone radial head arthroplasty has been successful in many patients, it has been associated with complications such as fractures of the prosthesis and silicone synovitis. Synovectomy and removal of the failed silicone radial head, with or without reimplantation of a metallic radial head, is indicated in such complications. In an effort to perform minimally invasive surgery, we performed arthroscopic removal of the silicone head combined with synovectomy in a series of such patients. The silicone prostheses were cut into two or three pieces and then removed. After a median follow up of 26 months, all patients reported excellent pain relief and there were no residual loose bodies. Removal of a failed silicone radial head can be successfully performed arthroscopically. This arthroscopic technique has the advantage of being minimally invasive and can be combined with other procedures including capsulectomy, if necessary.