A theoretical model of acoustoelectric transducer with a nonuniform distribution of piezoelectric coefficient: Application to transducer optimization
Chapeau‐Blondeau, François , Greenleaf, James F.

The Journal of the Acoustical Society of America | October 13, 2005 | Volume: 87 | Issue: 1 | Pages: 201-207

10.1121/1.399286 Get It

A general equation is derived that describes the behavior of a piezoelectric transducer with a nonuniform distribution of piezoelectric coefficient within its bulk, when submitted to an arbitrary distribution of acoustic pressure. Based on this equation, an expression for the receiving transfer function of the transducer is calculated. The results demonstrate the dependence of the transfer function on the distribution of piezoelectric coefficient, and that it is possible to benefit from a nonuniform distribution to optimize the transfer function. The general equation also describes the influence of the external electric circuit loading the transducer, which leads to another independent means of optimizing the transfer function. The proposed model combines effects of piezoelectric material characteristics, acoustic backing, and electric loading, without resorting to Mason or other equivalent circuits for the transducer.
An experimental study of acoustoelectric transducers with nonuniform distribution of the piezoelectric coefficient
Chapeau‐Blondeau, François , Greenleaf, J.F., Harrison, William B., Hanson, M. R. B.

The Journal of the Acoustical Society of America | October 13, 2005 | Volume: 86 | Issue: 4 | Pages: 1223-1229

10.1121/1.398735 Get It

In this paper, an experimental test of a theoretical model published previously is presented that describes the behavior of an acoustoelectric transducer with a nonuniform distribution of the piezoelectric coefficient within its bulk. Results of this theoretical model are first reviewed. Uniform and nonuniform piezoelectric transducers were fabricated, following a procedure described herein. The receive transfer functions of the transducers were recorded experimentally, and a comparison is made with the theoretical transfer functions predicted by the model, which shows good agreement. The transmit transfer functions of the uniform and nonuniform transducers were also measured and are reported. Numerical calculations of the different transfer functions given by the theoretical model for a uniform transducer associated with different backing materials are also presented, and the results are shown to be equivalent to the results following from the Mason equivalent circuit. Comparisons with experimental results and with Mason’s equivalent circuit verified the new theoretical model.