Back to Authors

Hayes, John

Mayo Clinic

Marshfield Clinic Research Foundation

Citations 2

Comparison of Inappropriate Shocks and Other Health Outcomes Between Single‐ and Dual‐Chamber Implantable Cardioverter‐Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Imp
Peterson, Pamela N., Greenlee, Robert T. , Go, Alan S. , Magid, David J. , Garcia‐Montilla, Romel , Glenn, Karen A., Gurwitz, Jerry H. , Hammill, Stephen C., Hayes, John, Kadish, Alan H. , Sharma, Param , Smith, David H. , Varosy, Paul D. , Vidaillet, Humberto, Zeng, Chan , Masoudi, Frederick A. , Peterson, Pamela N. , Cassidy‐Bushrow, Andrea E. , Reynolds, Kristi , Normand, Sharon‐Lise T.

Journal of the American Heart Association | November 10, 2017 | Volume: 6 | Issue: 11 | Pages: No page available

10.1161/jaha.117.006937 Get It

Background In US clinical practice, many patients who undergo placement of an implantable cardioverter‐defibrillator ( ICD ) for primary prevention of sudden cardiac death receive dual‐chamber devices. The superiority of dual‐chamber over single‐chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single‐ and dual‐chamber ICD s for primary prevention. Methods and Results We identified patients receiving a single‐ or dual‐chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health delivery systems in the Longitudinal Study of Implantable Cardioverter‐Defibrillators from 2006 to 2009. The primary outcome was time to first inappropriate shock. ICD shocks were adjudicated for appropriateness. Other outcomes included all‐cause hospitalization, heart failure hospitalization, and death. Patient, clinician, and hospital‐level factors were accounted for using propensity score weighting methods. Among 1042 patients without pacing indications, 54.0% (n=563) received a single‐chamber device and 46.0% (n=479) received a dual‐chamber device. In a propensity‐weighted analysis, device type was not significantly associated with inappropriate shock (hazard ratio, 0.91; 95% confidence interval, 0.59–1.38 [ P =0.65]), all‐cause hospitalization (hazard ratio, 1.03; 95% confidence interval, 0.87–1.21 [ P =0.76]), heart failure hospitalization (hazard ratio, 0.93; 95% confidence interval, 0.72–1.21 [ P =0.59]), or death (hazard ratio, 1.19; 95% confidence interval, 0.93–1.53 [ P =0.17]). Conclusions Among patients who received an ICD for primary prevention without indications for pacing, dual‐chamber devices were not associated with lower risk of inappropriate shock or differences in hospitalization or death compared with single‐chamber devices. This study does not justify the use of dual‐chamber devices to minimize inappropriate shocks.
Kidney function and appropriateness of device therapies in adults with implantable cardioverter defibrillators
Szpiro, Adam A. , Masoudi, Frederick A. , Greenlee, Robert T. , Smith, David H. , Magid, David J. , Gurwitz, Jerry H. , Tabada, Grace H., Sung, Sue Hee, Dighe, Ashveena , Garcia‐Montilla, Romel , Hammill, Stephen C., Hayes, John, Kadish, Alan H. , Sharma, Param , Varosy, Paul D. , Vidaillet, Humberto, Go, Alan S. , Hammill, Stephen, Bansal, Nisha , Reynolds, Kristi , Cassidy‐Bushrow, Andrea E.

Heart | October 14, 2016 | Volume: 103 | Issue: 7 | Pages: 529-537

10.1136/heartjnl-2016-309842 Get It

Objective Patients with chronic kidney disease (CKD) have higher risk of sudden cardiac death; however, they may not receive implantable cardioverter defibrillators (ICDs), in part due to higher risk of complications. We evaluated whether CKD is associated with greater risk of device-delivered shocks/antitachycardia pacing (ATP) therapies among patients receiving a primary prevention ICD. Methods We studied participants in the observational Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter Defibrillators. CKD was defined as estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Outcomes included all delivered shocks/ATPs therapies and type of shock/ATP therapies (inappropriate or appropriate, determined by physician adjudication) within the 3 years. We evaluated the associations between CKD and time to first device therapy, burden of device therapy, and inappropriate versus appropriate device therapy, adjusting for demographics, comorbidity, laboratory values and medication use. Results Among 2161 participants, 1066 (49.3%) had CKD (eGFR 44±11 mL/min/1.73 m2) at ICD implantation. During mean of 2.26±0.89 years, 9.8% and 18.5% of participants had at least one inappropriate and appropriate shock/ATP therapies, respectively. CKD was not associated with time to first shock/ATP therapies (adjusted HR 0.87, 95% CI 0.73 to 1.05), overall burden of shock/ATP therapies (adjusted relative rate 0.93, 95% CI 0.74 to 1.17) or inappropriate versus appropriate shock/ATP therapies (adjusted relative risk 0.88, 95% CI 0.68 to 1.14) compared with not having CKD. Conclusions In adults receiving a primary prevention ICD, mild-to-moderate CKD was not associated with the timing, burden or appropriateness of subsequent device therapy. Potential concern for inappropriate ICD-delivered therapies should not preclude ICDs among eligible patients with CKD.