BACKGROUND AND OBJECTIVES Neonatal tracheal intubation is a high-risk procedure, and multiple attempts are associated with adverse events. At our tertiary neonatal intensive care unit, the baseline first-attempt success rate was 45%, which we aimed to increase to over 55% through a quality improvement (QI) initiative. METHODS A multidisciplinary team conducted a QI project using the define-measure-analyze-improve-control framework. Root cause analysis identified poor glottic visualization and patient instability as primary drivers of failure. Plan-do-study-act cycles were carried out (April 2023–July 2024), followed by a sustainability phase (August 2024–May 2025). Key interventions included the phased implementation of video laryngoscopy (VL) as the primary intubation device and the standardization of oxygenation during laryngoscopy using nasal high flow. First-attempt success was tracked using statistical process control, and bimonthly VL use was monitored as a process measure. RESULTS A total of 642 intubations were analyzed. By control chart analysis, the first-attempt success rate increased from a baseline of 45% to a sustained process mean of 61% during the intervention and sustainability phases. VL use increased from 0% at baseline to 70% to 90% during the sustainability phase. Success rates improved across all clinician types and locations. Notably, first-attempt success in infants weighing less than 1000 g increased from 38% at baseline to 62% during the intervention phase. CONCLUSION A systematic QI initiative focused on VL and standardized oxygenation improved and sustained neonatal intubation success rates, exceeding the project aim. The maintenance of high-success rates confirms the durability of these safety improvements.
Patient and Device Interface Variables Affect Relative and Absolute Humidity Delivery
BACKGROUND: Respiratory therapists (RTs) work alongside allied health staff, nurses, and physicians during stressful and traumatic events that can be associated with emotional and physiological implications known as second victim (SV) experiences (SVEs). This study aimed to evaluate SVEs of RTs, including both positive and negative implications. METHODS: RTs within a large academic health care organization across Minnesota, Wisconsin, Florida, and Arizona were asked to participate in an anonymous survey that included the validated Second Victim Experience and Support Tool-Revised to assess SVEs as well as desired support services. RESULTS: Of the RTs invited to participate, 30.8% (171/555) completed the survey. Of the 171 survey respondents, 91.2% (156) reported that they had been part of a stressful or traumatic work-related event as an RT, student, or department support staff member. Emotional or physiologic implications experienced by respondents as SVs included anxiety 39.1% (61/156), reliving of the event 36.5% (57/156), sleeplessness 32.1% (50/156), and guilt 28.2% (44/156). Following a stressful clinical event, 14.8% (22/149) experienced psychological distress, 14.2% (21/148) experienced physical distress, 17.7% (26/147) indicated lack of institutional support, and 15.6% (23/147) indicated turnover intentions. Enhanced resilience and growth were reported by 9.5% (14/147). Clinical and non-clinical events were reported as possible triggers for SVEs. Nearly half of respondents 49.4% (77/156) indicated feeling like an SV due to events related to COVID-19. Peer support was the highest ranked form of desired support following an SVE by 57.7% (90/156). CONCLUSIONS: RTs are involved in stressful or traumatic clinical events, resulting in psychological/physical distress and turnover intentions. The COVID-19 pandemic has had a significant impact on RTs’ SVEs, highlighting the importance of addressing the SV phenomenon among this population.
1026: PROSPECTIVE STUDY COMPARING VIRTUAL REALITY TO LIVE DEMONSTRATION FOR NEONATAL INTUBATION EDUCATION
Introduction: Excessive alarm burden contributes to alarm fatigue, causing staff to ignore or delay response to clinically significant alarms. The objective of this quality improvement project was to reduce yellow self-resolving SpO2 alarms from a mean of 14 alarms/patient-hour (APH) to 7 APH (a 50% reduction) within a 6-month period, without significantly decreasing the amount of time spent in target SpO2 range (90%–95%). Methods: A multidisciplinary team used Define-Measure-Analyze-Improve-Control methodology to identify etiologies of alarm frequency and design improvement interventions to reduce alarm burden in a single-site Level IV NICU. Data-driven changes in alarm limit settings, alarm delay, and trial of a new pulse oximeter probe were used. Alarm data from the bedside monitor were analyzed following each improvement cycle. As a balancing measure, histograms monitored time spent in target SpO2 range. Results: SpO2 alarm data were collected for 4,320 patient-hours (180 patient-days) on 40 neonatal intensive care unit patients meeting inclusion criteria. Corresponding histograms were obtained for each patient day. Following 5 Plan-Do-Study-Act cycles, the mean number of yellow self-resolving SpO2 alarms decreased from 14 to 5 APH, a 64% decrease. There was no difference in time spent in target SpO2 range (50% versus 50%, P = 0.93). After achieving the project aim, 2 control phase measurements demonstrated sustained improvement (mean APH = 6). Conclusions: Yellow self-resolving SpO2 alarm frequency was reduced by 64% through the implementation of data-driven changes in alarm limit settings, alarm delays, and trial of a more sensitive oximeter probe without introducing harm to patients.
Improvement in Patient Transfer Process From the Operating Room to the PICU Using a Lean and Six Sigma–Based Quality Improvement Project
BACKGROUND AND OBJECTIVES: Ineffective and inefficient patient transfer processes can increase the chance of medical errors. Improvements in such processes are high-priority local institutional and national patient safety goals. At our institution, nonintubated postoperative pediatric patients are first admitted to the postanesthesia care unit before transfer to the PICU. This quality improvement project was designed to improve the patient transfer process from the operating room (OR) to the PICU. METHODS: After direct observation of the baseline process, we introduced a structured, direct OR-PICU transfer process for orthopedic spinal fusion patients. We performed value stream mapping of the process to determine error-prone and inefficient areas. We evaluated primary outcome measures of handoff error reduction and the overall efficiency of patient transfer process time. Staff satisfaction was evaluated as a counterbalance measure. RESULTS: With the introduction of the new direct OR-PICU patient transfer process, the handoff communication error rate improved from 1.9 to 0.3 errors per patient handoff (P = .002). Inefficiency (patient wait time and non–value-creating activity) was reduced from 90 to 32 minutes. Handoff content was improved with fewer information omissions (P < .001). Staff satisfaction significantly improved among nearly all PICU providers. CONCLUSIONS: By using quality improvement methodology to design and implement a new direct OR-PICU transfer process with a structured multidisciplinary verbal handoff, we achieved sustained improvements in patient safety and efficiency. Handoff communication was enhanced, with fewer errors and content omissions. The new process improved efficiency, with high staff satisfaction.