Abstract Background: Tyrosinemia type I (TYR 1) is a disorder causing early death if left untreated. Newborn screening (NBS) for this condition is problematic because determination of the diagnostic marker, succinylacetone (SUAC), requires a separate first-tier or only partially effective second-tier analysis based on tyrosine concentration. To overcome these problems, we developed a new assay that simultaneously determines acylcarnitines (AC), amino acids (AA), and SUAC in dried blood spots (DBS) by flow injection tandem mass spectrometry (MS/MS). Methods: We extracted 3/16-inch DBS punches with 300 μL methanol containing AA and AC stable isotope-labeled internal standards. This extract was derivatized with butanol-HCl. In parallel, we extracted SUAC from the residual filter paper with 100 μL of a 15 mmol/L hydrazine solution containing the internal standard 13C5-SUAC. We combined the derivatized aliquots in acetonitrile for MS/MS analysis of AC and AA with additional SRM experiments for SUAC (m/z 155–137) and 13C5-SUAC (m/z 160–142). Analysis time was 1.2 min. Results: SUAC was increased in retrospectively analyzed NBS samples of 11 TYR 1 patients (length of storage, 52 months to 1 week; SUAC range, 13–81 μmol/L), with Tyr concentrations ranging from 65 to 293 μmol/L in the original NBS analysis. The mean concentration of SUAC in 13 521 control DBS was 1.25 μmol/L. Conclusion: The inclusion of SUAC analysis into routine analysis of AC and AA allows for rapid and cost-effective screening for TYR 1 with no tangible risk of false-negative results.
Second-Tier Test for Quantification of Alloisoleucine and Branched-Chain Amino Acids in Dried Blood Spots to Improve Newborn Screening for Maple Syrup Urine Disease (MSUD)
AbstractBackground: Newborn screening for maple syrup urine disease (MSUD) relies on finding increased concentrations of the branched-chain amino acids (BCAAs) leucine, isoleucine, and valine by tandem mass spectrometry (MS/MS). d-Alloisoleucine (allo-Ile) is the only pathognomonic marker of MSUD, but it cannot be identified by existing screening methods because it is not differentiated from isobaric amino acids. Furthermore, newborns receiving total parenteral nutrition often have increased concentrations of BCAAs. To improve the specificity of newborn screening for MSUD and to reduce the number of diet-related false-positive results, we developed a LC-MS/MS method for quantifying allo-Ile.Methods: Allo-Ile and other BCAAs were extracted from a 3/16-inch dried blood spot punch with methanol/H2O, dried under nitrogen, and reconstituted into mobile phase. Quantitative LC-MS/MS analysis of allo-Ile, its isomers, and isotopically labeled internal standards was achieved within 15 min. To determine a reference interval for BCAAs including allo-Ile, we analyzed 541 dried blood spots. We also measured allo-Ile in blinded samples from 16 MSUD patients and 21 controls and compared results to an HPLC method.Results: Intra- and interassay imprecision (mean CVs) for allo-Ile, leucine, isoleucine, and valine ranged from 1.8% to 7.4%, and recovery ranged from 91% to 129%. All 16 MSUD patients were correctly identified.Conclusions: The LC-MS/MS method can reliably measure allo-Ile in dried blood spots for the diagnosis of MSUD. Applied to newborn screening as a second-tier test, it will reduce false-positive results, which produce family anxiety and increase follow-up costs. The assay also appears suitable for use in monitoring treatment of MSUD patients.
Reduction of the false‐positive rate in newborn screening by implementation of MS/MS‐based second‐tier tests: The Mayo Clinic experience (2004–2007)
SummaryThe continued expansion of newborn screening programmes to include additional conditions increases the responsibility of newborn screening laboratories to provide testing with the highest sensitivity and specificity to allow for identification of affected patients while minimizing the false‐positive rate. Some assays and analytes are particularly problematic. Over recent years, our laboratory tried to improve this situation by developing second‐tier tests to reduce false‐positive results in the screening for congenital adrenal hyperplasia (CAH), tyrosinaemia type I, methylmalonic acidaemias, homocystinuria, and maple syrup urine disease (MSUD). Beginning in 2004, this approach was applied to Mayo's newborn screening programme and resulted in a false‐positive rate of 0.09%, a positive predictive value of 41%, and a positive detection rate of 1 affected case in 1672 babies screened.
Automated Spectrophotometric Analysis of Mitochondrial Respiratory Chain Complex Enzyme Activities in Cultured Skin Fibroblasts
Abstract Background: Mitochondrial respiratory chain complex (RCC) disorders may occur as commonly as 1 in 8500 individuals. Because of the great variability of phenotypic presentations, measurement of individual RCC enzyme activities is a crucial diagnostic process. Current assay methods are time-consuming and labor-intensive and thus constitute a major impediment to clinical practice. A method with a faster turnaround time would therefore be beneficial. Method: We developed an automated spectrophotometric method for measuring the respiratory chain enzyme activities of complex I, complex II + III, and complex IV with the Hitachi 912, an automated spectrophotometer. Mitochondrial citrate synthase was also determined for normalization of the RCC activities. Results: A blinded method comparison with samples from an external testing center yielded a 91% concordance of interpretations. Mean intraassay imprecision (as CV; n = 20) in a single batch analysis of each RCC was 5.9%. Interassay imprecision, evaluated on 2 samples harvested and analyzed 3 times each, gave mean CVs of 10%–18%. Conclusions: With this automated method, a panel of RCC enzyme activities can be determined in <2 h. In addition, an immunoblot assay using monoclonal antibodies against specific subunits of RCC enzyme complexes can be informative in cases of borderline enzyme activity. Our results suggest that in vitro diagnosis of RCC enzyme deficiencies in skin fibroblasts is an effective alternative to invasive muscle biopsy.