Back to Authors

Amir, Amnon

https://orcid.org/0000-0002-0903-6056

Mayo Clinic

University of California San Diego

Citations 4

Comparison of Oral Collection Methods for Studies of Microbiota
Vogtmann, Emily , Chen, Jun , Amir, Amnon , Shi, Jianxin , Chen, Yu , Eunes, Mahbubul, Ahmed, Alauddin , Naher, Jabun, Rahman, Anisur, Barmon, Bhaswati, Knight, Rob , Ahsan, Habibul , Abnet, Christian C. , Chia, Nicholas , Abnet, Christian C , Kibriya, Muhammad Ghulam , Islam, Tariqul , Chia, Nicholas , Sinha, Rashmi R. , Chen, Yu

Cancer Epidemiology, Biomarkers & Prevention | September 27, 2018 | Volume: 28 | Issue: 1 | Pages: 137-143

10.1158/1055-9965.epi-18-0312 Get It

Abstract Background: A number of cohort studies have collected Scope mouthwash samples by mail, which are being used for microbiota measurements. We evaluated the stability of Scope mouthwash samples at ambient temperature and determined the comparability of Scope mouthwash with saliva collection using the OMNIgene ORAL Kit. Methods: Fifty-three healthy volunteers from Mayo Clinic and 50 cohort members from Bangladesh provided oral samples. One aliquot of the OMNIgene ORAL and Scope mouthwash were frozen immediately and one aliquot of the Scope mouthwash remained at ambient temperature for 4 days and was then frozen. DNA was extracted and the V4 region of the 16S rRNA gene was PCR amplified and sequenced using the HiSeq. Intraclass correlation coefficients (ICC) were calculated. Results: The overall stability of the Scope mouthwash samples was relatively high for alpha and beta diversity. For example, the meta-analyzed ICC for the Shannon index was 0.86 (95% confidence interval, 0.76–0.96). Similarly, the ICCs for the relative abundance of the top 25 genera were generally high. The comparability of the two sample types was relatively low when measured using ICCs, but were increased by using a Spearman correlation coefficient (SCC) to compare the rank order of individuals. Conclusions: Overall, the Scope mouthwash samples appear to be stable at ambient temperature, which suggests that oral rinse samples received by the mail can be used for microbial analyses. However, Scope mouthwash samples were distinct compared with OMNIgene ORAL samples. Impact: Studies should try to compare oral microbial metrics within one sample collection type.
Comparison of Fecal Collection Methods for Microbiota Studies in Bangladesh
Vogtmann, Emily , Chen, Jun , Chen, Yu , Eunes, Mahbubul, Ahmed, Alauddin , Naher, Jabun, Rahman, Anisur, Amir, Amnon , Shi, Jianxin , Abnet, Christian C. , Nelson, Heidi , Knight, Rob , Ahsan, Habibul , Chia, Nicholas , Kibriya, Muhammad Ghulam , Islam, Tariqul , Chia, Nicholas , Sinha, Rashmi R. , Abnet, Christian C , Chen, Yu

Applied and Environmental Microbiology | March 4, 2017 | Volume: 83 | Issue: 10 | Pages: No page available

10.1128/aem.00361-17 Get It

ABSTRACT To our knowledge, fecal microbiota collection methods have not been evaluated in low- and middle-income countries. Therefore, we evaluated five different fecal sample collection methods for technical reproducibility, stability, and accuracy within the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh. Fifty participants from the HEALS provided fecal samples in the clinic which were aliquoted into no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT) tubes. Half of the aliquots were frozen immediately at −80°C (day 0) and the remaining samples were left at ambient temperature for 96 h and then frozen (day 4). Intraclass correlation coefficients (ICC) were calculated for the relative abundances of the top three phyla, for two alpha diversity measures, and for four beta diversity measures. The duplicate samples had relatively high ICCs for technical reproducibility at day 0 and day 4 (range, 0.79 to 0.99). The FOBT card and samples preserved in RNAlater and 95% ethanol had the highest ICCs for stability over 4 days. The FIT tube had lower stability measures overall. In comparison to the “gold standard” method using immediately frozen fecal samples with no solution, the ICCs for many of the microbial metrics were low, but the rank order appeared to be preserved as seen by the Spearman correlation. The FOBT cards, 95% ethanol, and RNAlater were effective fecal preservatives. These fecal collection methods are optimal for future cohort studies, particularly in low- and middle-income countries. IMPORTANCE The collection of fecal samples in prospective cohort studies is essential to provide the opportunity to study the effect of the human microbiota on numerous health conditions. However, these collection methods have not been adequately tested in low- and middle-income countries. We present estimates of technical reproducibility, stability at ambient temperature for 4 days, and accuracy comparing a “gold standard” for fecal samples in no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test cards, and fecal immunochemical test tubes in a study conducted in Bangladesh. Fecal occult blood test cards and fecal samples stored in 95% ethanol or RNAlater adequately preserve fecal samples in this setting. Therefore, new studies in low- and middle-income countries should include collection of fecal samples using fecal occult blood test cards, 95% ethanol, or RNAlater for prospective cohort studies.
Fecal Microbiome in Epidemiologic Studies—Response
Vogtmann, Emily , Amir, Amnon , Shi, Jianxin , Flores, Roberto , Knight, Rob , Chia, Nicholas , Sinha, Rashmi R. , Chen, Jun , Sampson, Joshua N. , Chia, Nicholas

Cancer Epidemiology, Biomarkers & Prevention | March 10, 2016 | Volume: 25 | Issue: 5 | Pages: 870-871

10.1158/1055-9965.epi-16-0161 Get It

Collecting Fecal Samples for Microbiome Analyses in Epidemiology Studies
Amir, Amnon , Vogtmann, Emily , Shi, Jianxin , Inman, Kristin S. , Flores, Roberto , Knight, Rob , Chia, Nicholas , Sinha, Rashmi R. , Chen, Jun , Sampson, Joshua N. , Chia, Nicholas

Cancer Epidemiology, Biomarkers & Prevention | November 24, 2015 | Volume: 25 | Issue: 2 | Pages: 407-416

10.1158/1055-9965.epi-15-0951 Get It

Abstract Background: The need to develop valid methods for sampling and analyzing fecal specimens for microbiome studies is increasingly important, especially for large population studies. Methods: Some of the most important attributes of any sampling method are reproducibility, stability, and accuracy. We compared seven fecal sampling methods [no additive, RNAlater, 70% ethanol, EDTA, dry swab, and pre/post development fecal occult blood test (FOBT)] using 16S rRNA microbiome profiling in two laboratories. We evaluated nine commonly used microbiome metrics: abundance of three phyla, two alpha-diversities, and four beta-diversities. We determined the technical reproducibility, stability at ambient temperature, and accuracy. Results: Although microbiome profiles showed systematic biases according to sample method and time at ambient temperature, the highest source of variation was between individuals. All collection methods showed high reproducibility. FOBT and RNAlater resulted in the highest stability without freezing for 4 days. In comparison with no-additive samples, swab, FOBT, and 70% ethanol exhibited the greatest accuracy when immediately frozen. Conclusions: Overall, optimal stability and reproducibility were achieved using FOBT, making this a reasonable sample collection method for 16S analysis. Impact: Having standardized method of collecting and storing stable fecal samples will allow future investigations into the role of gut microbiota in chronic disease etiology in large population studies. Cancer Epidemiol Biomarkers Prev; 25(2); 407–16. ©2015 AACR.