Back to Authors

Revzin, Alexander

https://orcid.org/0000-0002-8737-3250

Mayo Clinic

Mayo Clinic

Citations 40

A Compact Control System to Enable Automated Operation of Microfluidic Bioanalytical Assays
Gonzalez‐Suarez, Alan M. , Long, Alexander , Huang, XuHai, Revzin, Alexander , Gonzalez-Suarez, Alan M

Biosensors | December 13, 2022 | Volume: 12 | Issue: 12 | Pages: 1160

10.3390/bios12121160 Get It

We describe a control system for operating valve-enabled microfluidic devices and leverage this control system to carry out a complex workflow of plasma separation from 8 μL of whole blood followed by on-chip mixing of plasma with assay reagents for biomarker detection. The control system incorporates pumps, digital pressure sensors, a microcontroller, solenoid valves and off-the-shelf components to deliver high and low air pressure in the desired temporal sequence to meter fluid flow and actuate microvalves. Importantly, our control system is portable, which is suitable for operating the microvalve-enabled microfluidic devices in the point-of-care setting.
A Microfluidic Device for Long‐Term Maintenance of Organotypic Liver Cultures
Hoyos‐Vega, José M. de , Hong, Hye Jin , Revzin, Alexander , Vega, José M de Hoyos, Loutherback, Kevin , de Hoyos-Vega, Jose M , Stybayeva, Gulnaz

Advanced Materials Technologies | October 3, 2022 | Volume: 8 | Issue: 2 | Pages: No page available

10.1002/admt.202201121 Get It

Abstract Liver cultures may be used for disease modeling, testing therapies, and predicting drug‐induced injury. The complexity of the liver cultures has evolved from hepatocyte monocultures to co‐cultures with non‐parenchymal cells and finally to precision‐cut liver slices. The latter culture format retains liver's native biomolecular and cellular complexity and therefore holds considerable promise for in vitro testing. However, liver slices remain functional for ≈72 h in vitro and display limited utility for some disease modeling and therapy testing applications that require longer culture times. This paper describes a microfluidic device for longer‐term maintenance of functional organotypic liver cultures. This microfluidic culture system is designed to enable direct injection of liver tissue into a culture chamber through a valve‐enabled side port. Liver tissue is embedded in collagen and remained functional for up to 31 days, highlighted by continued production of albumin and urea. These organotypic cultures also express several enzymes involved in xenobiotic metabolism. Conversely, matched liver tissue embedded in collagen in a 96‐well plate loses its phenotype and function within 3–5 days. The microfluidic organotypic liver cultures described here represent a significant advance in liver cultivation and may be used for future modeling of liver diseases or for individualized liver‐directed therapies.
ACCRU-GI-2008: A phase II randomized study of atezolizumab (Atezo) plus a multi-kinase inhibitor (MKI) versus MKI alone in patients with unresectable advanced hepatocellular carcinoma (aHCC) who previously received atezolizumab plus bevacizumab (Bev).
Li, Jing , Revzin, Alexander , Nelson, Garth D. , Ness, Andrew, Schuster, Carissa E., Jia, Jingquan, Wee, Wen , Ou, Fang‐Shu , Tran, Nguyen H. , Babiker, Hani M. , Dong, Haidong , Bekaii‐Saab, Tanios

Journal of Clinical Oncology | June 6, 2022 | Volume: 40 | Issue: 16_suppl | Pages: TPS4170-TPS4170

10.1200/jco.2022.40.16_suppl.tps4170 Get It

TPS4170 Background: IMbrave150 is the first study demonstrating the benefit of anti-PDL1 in the frontline treatment of aHCC, and established Atezo/Bev as a new 1st line standard for aHCC. There is currently limited evidence to guide subsequent therapy for aHCC patients progressing on Atezo/Bev. ACCRU-GI-2008 is designed to determine the benefit of continuing Atezo into 2nd line and the safety of Atezo plus a MKI in patients with aHCC who previously received Atezo/Bev. The study is being conducted across 12 centers in the United States (ClincalTrials.gov#: NCT05168163). Methods: This study utilizes a 2:1 randomized phase II design where eligible patients will receive either Atezo/MKI (experimental arm) or MKI alone (control). Patients will be stratified according to the MKI choice (cabozantinib or lenvatinib, per physician’s decision), etiology of HCC (viral vs. non-viral) and alpha-fetoprotein level ( < 400 vs. > = 400 ng/mL). The major eligibility criteria are histological/cytological diagnosis or clinical diagnosis of HCC per the AASLD or WASL 2018 guidelines, has advanced disease not amendable to curative treatment, previously received and progressed on Atezo/Bev, has received only 1 previous line of systemic therapy (2nd line only), ECOG PS 0-1, Child Pugh Class A, adequate organ reserves and RECIST v1.1 measurable disease; previous MKI for advanced disease is excluded. The primary endpoints are overall survival (OS) and progression free survival (PFS). A total sample size of 122, with 89 PFS events, we will have 80% power to detect an improvement in median PFS from 4 to 7 months, assuming a one-sided significance level of 0.05. With approximately 84 deaths, we will have 80% power to detect an improvement in median OS from 10 to 18 months, assuming a one-sided significance level of 0.05. The overall one-sided significance level, for the study, is 0.1. An OS interim analysis will be conducted at 89 PFS events. Secondary endpoints include objective response, duration of response, and adverse events. Archival tumor and serial blood samples will be collected to evaluate for potential prediction biomarkers and mechanisms of sensitivity/resistance. Baseline and on-treatment tumor biopsy specimens will also be collected from the initial 10 patients of each arm. The study is approved by the ethics committee and enrollment to the study will be underway by Q2/3 2022. Clinical trial information: NCT05168163.
Coating Bioactive Microcapsules with Tannic Acid Enhances the Phenotype of the Encapsulated Pluripotent Stem Cells
Gwon, Kihak , Hong, Hye Jin , Baskaran, Harihara , Calvo-Lozano, Olalla , Gonzalez‐Suarez, Alan M. , Park, Kyungtae , Lechuga, Laura M. , Hong, Jinkee , Revzin, Alexander , Choi, Daheui , Calvo-Lozano, Olalla , Gonzalez-Suarez, Alan M, Lechuga, Laura M , Hong, Jinkee , Revzin, Alexander , Gwon, Kihak , Gonzalez-Suarez, Alan M , Hoyos‐Vega, José M. de , Stybayeva, Gulnaz

ACS Applied Materials & Interfaces | June 4, 2022 | Volume: 14 | Issue: 23 | Pages: 27274-27286

10.1021/acsami.2c06783 Get It

Automated Microfluidic System with Active Mixing Enables Rapid Analysis of Biomarkers in 5 μL of Whole Blood
Gonzalez‐Suarez, Alan M. , Carey, William A., Revzin, Alexander , Revzin, Alexander , Gonzalez-Suarez, Alan M , Stybayeva, Gulnaz

Analytical Chemistry | May 23, 2022 | Volume: 94 | Issue: 27 | Pages: 9706-9714

10.1021/acs.analchem.2c01139 Get It

New Methodology for Accurate Determination of Molecular Co-localization at the Nanoscale
Verkhoturov, Dmitriy S., Eller, Michael J. , Han, Yong Duk, Верхотуров, С. В., Revzin, Alexander , Eller, Michael J , Schweikert, Emile A , Crulhas, Bruno P.

Langmuir | April 25, 2022 | Volume: 38 | Issue: 18 | Pages: 5626-5632

10.1021/acs.langmuir.2c00217 Get It

Understanding Suboptimal Response to Immune Checkpoint Inhibitors
Zhu, Mojun , Pedersen, Katrina S. , Foster, Nathan R. , Jaszewski, Brandy L., Liu, Xin , Hirdler, Jacob B. , An, Zesheng , Bekaii‐Saab, Tanios , Yan, Yiyi , Hubbard, Joleen H., Yoon, Harry H. , Revzin, Alexander , Fernández-Zapico, Martín E. , Overman, Michael J. , Dong, Haidong , Bekaii-Saab, Tanios S , Pedersen, Katrina , Zhang, Henan , Hálfdánarson, Þorvarður R. , Boland, Patrick M. , Hubbard, Joleen M. , Wee, Wen , McWilliams, Robert R. , Dong, Haidong

Advanced Biology | March 27, 2022 | Volume: 7 | Issue: 4 | Pages: No page available

10.1002/adbi.202101319 Get It

AbstractImmune checkpoint inhibitors (ICIs), as a novel class of anticancer therapy, can be more efficacious and less toxic than chemotherapy, but their clinical success is confined to certain tumor types. Elucidating their targets, mechanisms and scope of action, and potential synergism with chemotherapy and/or targeted therapies are critical to widen their clinical indications. Treatment response to an ICI targeting programmed death‐1 (anti‐PD‐1) is sought to be understood here by conducting a preplanned correlative analysis of a phase II clinical trial in patients with small bowel adenocarcinoma (SBA). The cytolytic capacity of circulating immune cells in cancer patients using a novel ex vivo cytotoxicity assay is evaluated, and the utility of circulating biomarkers is investigated to predict and monitor the treatment effect of anti‐PD‐1. Baseline expression of Bim and NKG7 and upregulation of CX3CR1 in circulating T cells are associated with the clinical benefit of anti‐PD‐1 in patients with SBA. Overall, these findings suggest that the frequency and cytolytic capacity of circulating, effector immune cells may differentiate clinical response to ICIs, providing a strong rationale to support immune monitoring using patient peripheral blood.
Nanoparticle-Enabled Multiplexed Electrochemical Immunoassay for Detection of Surface Proteins on Extracellular Vesicles
Lee, Seonhwa , Verkhoturov, Stanislav V. , Verkhoturov, Dmitriy S., Eller, Michael J. , Revzin, Alexander , Crulhas, Bruno P. , Eller, Michael J , Schweikert, Emile A , Revzin, Alexander , Šuvakov, Sonja , Malhi, Harmeet , Garovic, Vesna D. , Stybayeva, Gulnaz

ACS Applied Materials & Interfaces | October 28, 2021 | Volume: 13 | Issue: 44 | Pages: 52321-52332

10.1021/acsami.1c14506 Get It

Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors
Hoyos‐Vega, José M. de , Hong, Hye Jin , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Stybayeya, Gulnaz

APL Bioengineering | October 14, 2021 | Volume: 5 | Issue: 4 | Pages: No page available

10.1063/5.0058798 Get It

Hepatocytes are parenchymal cells of the liver responsible for drug detoxification, urea and bile production, serum protein synthesis, and glucose homeostasis. Hepatocytes are widely used for drug toxicity studies in bioartificial liver devices and for cell-based liver therapies. Because hepatocytes are highly differentiated cells residing in a complex microenvironment in vivo, they tend to lose hepatic phenotype and function in vitro. This paper first reviews traditional culture approaches used to rescue hepatic function in vitro and then discusses the benefits of emerging microfluidic-based culture approaches. We conclude by reviewing integration of hepatocyte cultures with bioanalytical or sensing approaches.
Nanoprojectile Secondary Ion Mass Spectrometry for Analysis of Extracellular Vesicles
Verkhoturov, Dmitriy S., Crulhas, Bruno P. , Eller, Michael J. , Han, Yong Duk, Verkhoturov, Stanislav V. , Bisrat, Yordanos, Revzin, Alexander , Han, Yong D, Schweikert, Emile A , Eller, Michael J

Analytical Chemistry | May 14, 2021 | Volume: 93 | Issue: 20 | Pages: 7481-7490

10.1021/acs.analchem.1c00689 Get It