Back to Authors

Nesbitt, Rebecca J.

Mayo Clinic

University of Cincinnati

Citations 2

Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks
Bates, Nathaniel A. , Nesbitt, Rebecca J., Shearn, Jason T. , Myer, Gregory D. , Hewett, Timothy E. , Bates, Nathaniel A , Myer, Gregory D

The American Journal of Sports Medicine | April 12, 2016 | Volume: 44 | Issue: 7 | Pages: 1762-1770

10.1177/0363546516639303 Get It

Background: Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. Purpose: To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Study Design: Descriptive laboratory study. Methods: A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, −7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. Results: The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction ( r = 0.60-0.65), flexion ( r = 0.64-0.66), lateral ( r = 0.57-0.69), and external rotation torques ( r = 0.47-0.72) as well as inverse correlations with peak abduction ( r = −0.42 to −0.61) and internal rotation torques ( r = −0.39 to −0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque ( r = 0.64-0.69) and lateral knee force ( r = 0.55-0.74) as well as inverse correlations with peak external torque ( r = −0.34 to −0.67) and medial knee force ( r = −0.58 to −0.59). These moderate correlations were also present during simulated sidestep cutting. Conclusion: The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically, internally generated knee adduction and flexion torques. Clinical Relevance: The knee torques that positively correlated with increased tibial slope angle in this investigation are associated with heightened risk of ACL injury. Therefore, the present data indicated that a higher posterior tibial slope is correlated to increased knee loads that are associated with heightened risk of ACL injury.
Relative Strain in the Anterior Cruciate Ligament and Medial Collateral Ligament During Simulated Jump Landing and Sidestep Cutting Tasks
Bates, Nathaniel A. , Nesbitt, Rebecca J., Shearn, Jason T. , Myer, Gregory D. , Hewett, Timothy E. , Bates, Nathaniel A , Myer, Gregory D

The American Journal of Sports Medicine | July 6, 2015 | Volume: 43 | Issue: 9 | Pages: 2259-2269

10.1177/0363546515589165 Get It

Background: The medial collateral (MCL) and anterior cruciate ligaments (ACL) are, respectively, the primary and secondary ligamentous restraints against knee abduction, which is a component of the valgus collapse often associated with ACL rupture during athletic tasks. Despite this correlation in function, MCL ruptures occur concomitantly in only 20% to 40% of ACL injuries. Hypothesis/Purpose: The purpose of this investigation was to determine how athletic tasks load the knee joint in a manner that could lead to ACL failure without concomitant MCL failure. It was hypothesized that (1) the ACL would provide greater overall contribution to intact knee forces than the MCL during simulated motion tasks and (2) the ACL would show greater relative peak strain compared with the MCL during simulated motion tasks. Study Design: Controlled laboratory study. Methods: A 6-degrees-of-freedom robotic manipulator articulated 18 cadaveric knees through simulations of kinematics recorded from in vivo drop vertical jump and sidestep cutting tasks. Specimens were articulated in the intact-knee and isolated-ligament conditions. After simulation, each ACL and MCL was failed in uniaxial tension along its fiber orientations. Results: During a drop vertical jump simulation, the ACL experienced greater peak strain than the MCL (6.1% vs 0.4%; P < .01). The isolated ACL expressed greater peak anterior force (4.8% vs 0.3% body weight; P < .01), medial force (1.6% vs 0.4% body weight; P < .01), flexion torque (8.4 vs 0.4 N·m; P < .01), abduction torque (2.6 vs 0.3 N·m; P < .01), and adduction torque (0.5 vs 0.0 N·m; P = .03) than the isolated MCL. During failure testing, ACL specimens preferentially loaded in the anteromedial bundle failed at 637 N, while MCL failure occurred at 776 N. Conclusion: During controlled physiologic athletic tasks, the ACL provides greater contributions to knee restraint than the MCL, which is generally unstrained and minimally loaded. Clinical Relevance: Current findings support that multiplanar loading during athletic tasks preferentially loads the ACL over the MCL, leaving the ACL more susceptible to injury. An enhanced understanding of joint loading during in vivo tasks may provide insight that enhances the efficacy of injury prevention protocols.