Back to Authors

Hull, Nathan C.

https://orcid.org/0000-0003-1432-5781

Mayo Clinic

Department of Radiology, Division of Pediatric Radiology

Citations 22

“An unusual case of diffuse cystic lung disease: A teenager with lung metastasis”
Guler, Sevim , NC, Hull, Arteta, Manuel , Demirel, Nadir , Guler, Sevim , Hull, Nathan C.

No container title available | July 17, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.168963127.72176788/v1 Get It

We are presenting a teenage girl with a recent history of virilism who presented with tension pneumothorax. Subsequent contrast-enhanced chest CT revealed multiple bilateral irregular thin-walled cysts of varying sizes with numerous solid noncalcified pulmonary nodules and pulmonary artery pseudoaneurysms. Lung biopsy revealed trophoblastic neoplasm with metastasis to both lungs. We discussed the differential diagnosis of diffuse cystic lung diseases. While diffuse cystic lung diseases in children are rarely due to malignancy, we emphasize that clinicians be aware of the possibility of metastatic lung diseases and their radiologic features when encountering diffuse cystic lung diseases.
Predictive power of chest radiography for infectious or inflammatory lung disease
Hull, Nate C., Thacker, Paul G. , Boesch, R. Paul , Boesch, Richard P , Hull, Nathan C.

Pediatric Pulmonology | July 11, 2023 | Volume: 58 | Issue: 10 | Pages: 2804-2808

10.1002/ppul.26591 Get It

AbstractObjectiveChildren frequently present with chronic cough, recurrent respiratory infections, and dysphagia. These symptoms are poor predictors of significant inflammatory lung disease, such as from chronic aspiration. Bronchoalveolar lavage (BAL) is the gold standard for identification of lung infection and airway inflammation but is expensive and requires sedation. Chest X‐rays (CXR) are inexpensive, low‐radiation tests that do not require sedations and can document findings associated with infectious or inflammatory lung disease. The accuracy of CXR to predict or exclude infectious or inflammatory lung disease has not been directly evaluated and is unknown.MethodsRetrospective cohort of all pediatric patients who underwent FFB with BAL within 2 weeks of a CXR. Blinded CXR images reviewed for findings consistent with inflammatory disease by two senior pediatric radiologists. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for CXR to identify significant inflammation and/or infection on BAL were calculated.ResultsThree hundred and forty‐four subjects included. Two hundred and sixty‐three had positive CXR (77%), 183 had inflammatory BAL (53%), and 110 had infection (32%). The sensitivity of CXR changes for BAL inflammation, infection, and either inflammation or infection was 84.7, 90.9, and 85.3, respectively. The PPV of CXR was 58.9, 38.0, and 59.7. The NPV of CXR was 65.0, 87.5, and 66.3.ConclusionsAlthough CXR are inexpensive, do not require sedation, and are of low radiation dose, the ability of an entirely normal CXR to exclude active inflammatory or infectious lung disease is limited.
Normative Femoral and Tibial Lengths in a Modern Population of Twenty-First-Century U.S. Children
Chen, Chun‐Ho , Milbrandt, Todd A. , Babadi, Elham , Duong, Stephanie Q. , Larson, Dirk R. , Shaughnessy, William J. , Stans, Anthony A. , Hull, Nathan C. , Peterson, Hamlet A. , Larson, A. Noelle , Chen, Chunho , Larson, A Noelle , Larson, Dirk

Journal of Bone and Joint Surgery | February 2, 2023 | Volume: 105 | Issue: 6 | Pages: 468-478

10.2106/jbjs.22.00690 Get It

Background: The Green-Anderson (GA) leg-length data remain the gold standard for the age-based assessment of leg lengths in children despite their methodologic weaknesses. We aimed to summarize current growth trends among a cross-sectional cohort of modern U.S. children using quantile regression methods and to compare the median femoral and tibial lengths of the modern U.S. children with those of the GA cohort. Methods: A retrospective review of scanograms and upright slot-scanning radiographs obtained in otherwise healthy children between 2008 and 2020 was completed. A search of a radiology registry revealed 3,508 unique patients between the ages of 2 and 18 years for whom a standard-of-care scanogram or slot-scanning radiograph had been made. All patients with systemic illness, genetic conditions, or generalized diseases that may affect height were excluded. Measurements from a single leg at a single time point per subject were included, and the latest available time point was used for children who had multiple scanograms made. Quantile regression analysis was used to fit the lengths of the tibia and femur and overall leg length separately for male patients and female patients. Results: Seven hundred patients (328 female and 372 male) met the inclusion criteria. On average, the reported 50th percentile tibial lengths from the GA study at each time point were shorter than the lengths in this study by 2.2 cm (range, 1.4 to 3.3 cm) for boys and 2 cm (range, 1.1 to 3.1 cm) for girls. The reported 50th percentile femoral lengths from the GA study at each time point were shorter than the lengths in this study by 1.8 cm (range, 1.1 to 2.5 cm) for boys and 1.7 cm (range, 0.8 to 2.3 cm) shorter for girls. Conclusions: This study developed new growth charts for femoral and tibial lengths in a modern U.S. population of children. The new femoral and tibial lengths at nearly all time points are 1 to 3 cm longer than traditional GA data. The use of GA data for epiphysiodesis could result in underestimation of expected childhood growth. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Editorial Comment: Hepatocellular Carcinoma Screening Guidelines Are Needed in Children With Predisposing Conditions
Hull, Nathan C.

American Journal of Roentgenology | May 18, 2022 | Volume: 219 | Issue: 4 | Pages: 654-654

10.2214/ajr.22.27975 Get It

Abdominal Discomfort, Altered Bowel Habits, and Weight Loss in a 13-year-old Girl
Ariagno, Sydney , Jeeji, Archana, Hull, Nathan C. , Absah, Imad , Hull, Nathan, Ariagno, Sydney , Jeeji, Archana K.

Pediatrics In Review | August 2, 2021 | Volume: 42 | Issue: 8 | Pages: 457-462

10.1542/pir.2020-000802 Get It

Procedure for optimal implementation of automatic tube potential selection in pediatric CT to reduce radiation dose and improve workflow
Browne, Jacinta E. , Bruesewitz, Michael R. , Thomas, Vrieze, Thomas, Kristen B. , Hull, Nathan C. , Yu, Lifeng , Browne, Jacinta , McCollough, Cynthia H. , Yu, Lifeng

Journal of Applied Clinical Medical Physics | December 18, 2020 | Volume: 22 | Issue: 2 | Pages: 194-202

10.1002/acm2.13098 Get It

AbstractIt is important to employ radiation dose reduction techniques in pediatric computed tomography (CT) to reduce potential risks of radiation‐induced malignancy. Automatic tube potential (kV) selection tools have been developed and become available on many CT scanners, which select the optimum kV based on the patient size and clinical task to improve the radiation dose efficiency. However, its use in pediatric CT has been mostly empirical, following manufacturer’s default recommendation without solid demonstration for quality improvement. This study aimed to implement an automatic tube potential tool (CAREkV, Siemens Healthcare) into routine pediatric CT practice, using the “Plan‐Do‐Study‐Act” quality improvement process, in place of an existing kV/mAs technique chart. The design of this quality improvement project involved Plan‐Do‐Study‐Act stages. Plan and Do stages identified the criteria for optimal automatic kV selection; a range of phantoms representing typical pediatric groups were scanned on a dual‐source 128‐slice scanner using a fast‐pitch scanning mode. The identified CAREkV settings were implemented into the CT protocol and evaluated after a 6‐month period. In the Study stage, an objective evaluation of the image metrics and radiation dose for two similar patient cohorts using CAREkV and the technique‐chart, respectively, were compared. The kV selected, image quality and radiation dose determined by CAREkV were comparable to those obtained while using the technique‐chart. The CAREkV was successfully implemented into our pediatric abdominopelvic CT practice. By utilizing the “PDSA” process optimal image quality and radiation dose reduction were achieved with an automatic kV selection tool to improve CT workflow.
S1219 Prediction of Surgical Intervention for Crohn’s Perianal Fistula in Children: Predictive Patient Demographic and Anatomic Features by MRI
Khan, Muhammad Rehan , Hull, Nathan C. , Ulrich, Jessica A., Harmsen, William S. , Faubion, William A. , Absah, Imad , Inoue, Akitoshi , Fletcher, Joel G.

American Journal of Gastroenterology | October 24, 2020 | Volume: 115 | Issue: 1 | Pages: S610-S611

10.14309/01.ajg.0000706924.57387.45 Get It

Pediatric Patients and Diagnostic Thoracentesis: Utility for Identifying a Microorganism and Guiding Patient Management
Thacker, Paul G. , Kolbe, Amy B. , Hull, Nathan C. , Thomas, Kristen B. , Geske, Jennifer R. , Binkovitz, Larry A. , Geske, Jennifer

Radiology | August 25, 2020 | Volume: 297 | Issue: 2 | Pages: 449-450

10.1148/radiol.2020201511 Get It

Hepatobiliary MRI Contrast Agents: Pattern Recognition Approach to Pediatric Focal Hepatic Lesions
Schooler, Gary R. , Hull, Nathan C. , Lee, Edward Y.

American Journal of Roentgenology | March 17, 2020 | Volume: 214 | Issue: 5 | Pages: 976-986

10.2214/ajr.19.22239 Get It

Awareness of implicit bias mitigates discrimination in radiology resident selection
Maxfield, Charles M. , Thorpe, Matthew , Desser, Terry S. , Hull, Nathan C. , Johnson, Karen S., Koontz, Nicholas A. , Mlady, Gary, Thorpe, Matthew P, Welch, Timothy J. , Maxfield, Charles , Heitkamp, Darel E. , Welch, Timothy J., Grimm, Lars J.

Medical Education | March 2, 2020 | Volume: 54 | Issue: 7 | Pages: 637-642

10.1111/medu.14146 Get It

Abstract Objectives Implicit bias is common and is thought to drive discriminatory behaviour. Having previously demonstrated discrimination against specific applicant demographics by academic radiology departments in a simulated resident selection process, the authors sought to better understand the relationship between implicit bias and discrimination, as well as the potential and mechanisms for their mitigation. Methods A total of 51 faculty reviewers at three academic radiology departments, who had participated in a 2017 audit study in which they were shown to treat applicants differently based on race or ethnicity and physical appearance, were invited to complete testing for implicit racial and weight bias using the Implicit Association Test in 2019. Respondents were also surveyed regarding awareness of their own personal racial and weight biases, as well as any prior participation in formal diversity training. Comparisons were made between implicit bias scores and applicant ratings, as well as between diversity training and self‐awareness of bias. Results A total of 31 out of 51 faculty reviewers (61%) completed and submitted results of race and weight Implicit Association Tests. A total of 74% (23/31) reported implicit anti‐obese bias, concordant with discrimination demonstrated in the resident selection simulation, in which obese applicants were rated 0.40 standard deviations (SDs) lower than non‐obese applicants ( P < .001). A total of 71% (22/31) reported implicit anti‐Black bias, discordant with application ratings, which were 0.47 SDs higher for Black than for White applicants ( P < .001). A total of 84% (26/31) of participants reported feeling self‐aware of potential racial bias at the time of application review, significantly higher than the 23% (7/31) reporting self‐awareness of potential anti‐obese bias ( P < .001). Participation in formal diversity training was not associated with implicit anti‐Black or anti‐fat bias, nor with self‐reported awareness of potential racial or weight‐based bias (all P > .2). Conclusions These findings suggest that implicit bias, as measured by the Implicit Association Test, does not inevitably lead to discrimination, and that personal awareness of implicit biases may allow their mitigation.