Resistive and elastic work of breathing in older and younger adults during exercise
Smith, Joshua R. , Cross, Troy J. , Iterson, Erik H. Van , Johnson, Bruce D. , Olson, Thomas P. , Van Iterson, Erik H , Smith, Joshua R , Cross, Troy James

Journal of Applied Physiology | April 19, 2018 | Volume: 125 | Issue: 1 | Pages: 190-197

10.1152/japplphysiol.01105.2017 Get It

It is unknown whether the greater total work of breathing (WOB) with aging is due to greater elastic and/or resistive WOB. We hypothesized that older compared with younger adults would exhibit a greater total WOB at matched ventilations (V̇e) during graded exercise, secondary to greater inspiratory resistive and elastic as well as expiratory resistive WOB. Older (OA: 60 ± 8 yr; n = 9) and younger (YA: 38 ± 7 yr; n = 9) adults performed an incremental cycling test to volitional fatigue. Esophageal pressure, inspiratory (IRV) and expiratory reserve volumes (ERV), expiratory flow limitation (EFL), and ventilatory variables were measured at matched V̇e (i.e., 25, 50, and 75 l/min) during exercise. The inspiratory resistive and elastic as well as expiratory resistive WOB were quantified using the Otis method. At V̇e of 75 l/min, older adults had greater %EFL and larger tidal volumes to inspiratory capacity but smaller relative IRV ( P ≤ 0.03) than younger adults. Older compared with younger adults had greater total WOB at V̇Eof 50 and 75 l/min (OA: 90 ± 43 vs. YA: 49 ± 21 J/min; P < 0.04 for both). At V̇e of 75 l/min, older adults had greater inspiratory elastic and resistive WOB (OA: 44 ± 27 vs. YA: 24 ± 22 and OA: 23 ± 15 vs. YA: 11 ± 3 J/min, respectively, P < 0.03 for both) and expiratory resistive WOB (OA: 23 ± 19 vs. YA: 14 ± 9 J/min, P = 0.02) than younger adults. These data demonstrate that aging-induced pulmonary alterations result in greater inspiratory elastic and resistive as well as expiratory resistive WOB, which may have implications for the integrated response during exercise.NEW & NOTEWORTHY Aging-induced changes to the pulmonary system result in increased work of breathing (WOB) during exercise. However, it is not known whether this higher WOB with aging is due to differences in elastic and/or resistive WOB. Herein, we demonstrate that older adults exhibited greater inspiratory elastic and resistive as well as expiratory resistive WOB during exercise.
The influence of thoracic gas compression and airflow density dependence on the assessment of pulmonary function at high altitude
Cross, Troy J. , Wheatley, Courtney M. , Stewart, Glenn M. , Coffman, Kirsten E. , Carlson, Alex R. , Morris, Norman , Johnson, Bruce D. , Wheatley, Courtney, Coffman, Kirsten, Carlson, Alex, Stepánek, Jan , Cross, Troy James , Stepánek, Jan

Physiological Reports | April 1, 2018 | Volume: 6 | Issue: 6 | Pages: e13576

10.14814/phy2.13576 Get It

Exertional dyspnea associated with chest wall strapping is reduced when external dead space substitutes for part of the exercise stimulus to ventilation
Garske, Luke , Lal, Ravin, Stewart, Ian B. , Morris, Norman , Cross, Troy J. , Adams, Lewis, Cross, Troy James

Journal of Applied Physiology | February 3, 2017 | Volume: 122 | Issue: 5 | Pages: 1179-1187

10.1152/japplphysiol.00051.2016 Get It

Chest wall strapping has been used to assess mechanisms of dyspnea with restrictive lung disease. This study examined the hypothesis that dyspnea with restriction depends principally on the degree of reflex ventilatory stimulation. We compared dyspnea at the same (iso)ventilation when added dead space provided a component of the ventilatory stimulus during exercise. Eleven healthy men undertook a randomized controlled crossover trial that compared four constant work exercise conditions: 1) control (CTRL): unrestricted breathing at 90% gas exchange threshold (GET); 2) CTRL+dead space (DS): unrestricted breathing with 0.6-l dead space, at isoventilation to CTRL due to reduced exercise intensity; 3) CWS: chest wall strapping at 90% GET; and 4) CWS+DS: chest strapping with 0.6-l dead space, at isoventilation to CWS with reduced exercise intensity. Chest strapping reduced forced vital capacity by 30.4 ± 2.2% (mean ± SE). Dyspnea at isoventilation was unchanged with CTRL+DS compared with CTRL (1.93 ± 0.49 and 2.17 ± 0.43, 0–10 numeric rating scale, respectively; P = 0.244). Dyspnea was lower with CWS+DS compared with CWS (3.40 ± 0.52 and 4.51 ± 0.53, respectively; P = 0.003). Perceived leg fatigue was reduced with CTRL+DS compared with CTRL (2.36 ± 0.48 and 2.86 ± 0.59, respectively; P = 0.049) and lower with CWS+DS compared with CWS (1.86 ± 0.30 and 4.00 ± 0.79, respectively; P = 0.006). With unrestricted breathing, dead space did not change dyspnea at isoventilation, suggesting that dyspnea does not depend on the mode of reflex ventilatory stimulation in healthy individuals. With chest strapping, dead space presented a less potent stimulus to dyspnea, raising the possibility that leg muscle work contributes to dyspnea perception independent of the ventilatory stimulus. NEW & NOTEWORTHY Chest wall strapping was applied to healthy humans to simulate restrictive lung disease. With chest wall strapping, dyspnea was reduced when dead space substituted for part of a constant exercise stimulus to ventilation. Dyspnea associated with chest wall strapping depended on the contribution of leg muscle work to ventilatory stimulation. Chest wall strapping might not be a clinically relevant model to determine whether an alternative reflex ventilatory stimulus mimics the intensity of exertional dyspnea.
Correcting the dynamic response of a commercial esophageal balloon-catheter
Cross, Troy J. , Beck, Kenneth C., Johnson, Bruce D. , Cross, Troy James

Journal of Applied Physiology | July 12, 2016 | Volume: 121 | Issue: 2 | Pages: 503-511

10.1152/japplphysiol.00155.2016 Get It

It is generally recommended that an esophageal balloon-catheter possess an adequate frequency response up to 15 Hz, such that parameters of respiratory mechanics may be quantified with precision. In our experience, however, we have observed that some commercially available systems do not display an ideal frequency response (<8-10 Hz). We therefore investigated whether the poor frequency response of a commercially available esophageal catheter may be adequately compensated using two numerical techniques: 1) an exponential model correction, and 2) Wiener deconvolution. These two numerical techniques were performed on a commercial balloon-catheter interfaced with 0, 1, and 2 lengths of extension tubing (90 cm each), referred to as configurations L0, L90, and L180, respectively. The frequency response of the balloon-catheter in these configurations was assessed by empirical transfer function analysis, and its “working” range was defined as the frequency beyond which more than 5% amplitude and/or phase distortion was observed. The working frequency range of the uncorrected balloon-catheter extended up to only 10 Hz for L0, and progressively worsened with additional tubing length (L90 = 3 Hz, L180 = 2 Hz). Although both numerical methods of correction adequately enhanced the working frequency range of the balloon-catheter to beyond 25 Hz for all length configurations (L0, L90, and L180), Wiener deconvolution consistently provided more accurate corrections. Our data indicate that Wiener deconvolution provides a superior correction of the balloon-catheter's dynamic response, and is relatively more robust to extensions in catheter tube length compared with the exponential correction method.
The impact of venous occlusion per se on forearm muscle blood flow: implications for the near‐infrared spectroscopy venous occlusion technique
Cross, Troy J. , Sabapathy, Surendran , Cross, Troy James

Clinical Physiology and Functional Imaging | October 2, 2015 | Volume: 37 | Issue: 3 | Pages: 293-298

10.1111/cpf.12301 Get It

SummaryThe purpose of this study was to examine the effect of venous occlusion per se on forearm muscle blood flow, as determined by the near‐infrared spectroscopy (NIRS) venous occlusion technique (NIRS‐VOT). NIRS data were obtained from the flexor digitorum superficialis (FDS) muscle on the dominant arm of 16 young, ostensibly healthy participants (14 men and two women; 30 ± 6 year; 73 ± 7 kg). Participants completed a series of five venous occlusion trials while seated at rest, and a series of 12 venous occlusion trials during a reactive hyperaemia induced by 5 min of forearm arterial occlusion. The NIRS‐VOT was used to assess FDS muscle blood flow (), beat‐by‐beat, over the first four cardiac beats during venous occlusions. was also reported as a cumulative value, wherein the first two, first three and first four cardiac beats were used to calculate muscle blood flow. We observed that was highest when calculated over the first cardiac beat during venous occlusions performed at rest and throughout reactive hyperaemia (P<0·05). Moreover, the inclusion of more than one cardiac beat in the calculation of underestimated muscle blood flows, irrespective of the prevailing level of arterial inflow. These findings support the idea that venous occlusion per se affects the measurement of via the NIRS‐VOT. Accordingly, it is recommended that is determined over the first cardiac beat when using the NIRS‐VOT to assess microvascular blood flow of human forearm muscles.
The Impact of Averaging Window Length on the “Desaturation” Indexes Obtained Via Overnight Pulse Oximetry at High Altitude
Cross, Troy J. , Keller‐Ross, Manda L. , Issa, Amine, Wentz, Robert J., Taylor, Bryan J. , Johnson, Bruce D. , Keller-Ross, Manda, Wentz, Robert, Cross, Troy James , Taylor, Bryan J , Keller-Ross, Manda

Sleep | July 31, 2015 | Volume: 38 | Issue: 8 | Pages: 1331-1334

10.5665/sleep.4920 Get It

Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials
Lalande, Sophie , Hyatt, Robert E., Johnson, Bruce D. , Cross, Troy J.

Physiological Reports | June 16, 2015 | Volume: 3 | Issue: 6 | Pages: e12426

10.14814/phy2.12426 Get It