Back to Authors

Waletzki, Brian E.

Mayo Clinic

MilliporeSigma (United States)

Citations 16

Do bone elasticity and postmortem interval affect forensic fractographic analyses?
Skinner, Jessica , Joseph, Malin, Herrick, James L., Brown, Robert D. , Waletzki, Brian E., Goguen, Peter, Rajan, Subramaniam , Langley, Natalie, Herrick, James, Langley, Natalie R. , Shyamsunder, Loukham

Journal of Forensic Sciences | April 14, 2023 | Volume: 68 | Issue: 3 | Pages: 757-767

10.1111/1556-4029.15237 Get It

AbstractForensic fractographic features of bone reliably establish crack propagation in perimortem injuries. We investigated if similar fracture surface features characterize postmortem fractures. Experimentally induced peri‐ and postmortem fractures were used to assess if fractographic features vary as bone elasticity decreases during the postmortem interval (PMI). Thirty‐seven unembalmed, defleshed human femoral shafts from males and females aged 33–81 years were fractured at varying PMIs with a drop test frame using a three‐point bending setup and recorded with a high‐speed camera. Vital statistics, cause of death, PMI length, temperature, humidity, collagen percentage, water loss, fracture energy, and fractography scores were recorded for each sample. Results showed that fractographic features associated with perimortem fractures were expressed in PMIs up to 40,600 accumulated degree hours (ADH), or 60 warm weather days. Hackle was the most consistently expressed feature, occurring in all fractures regardless of ADH. The most variable characteristics were wake features (78.4%) and arrest ridges (70.3%). Collagen percentage did not correlate strongly with ADH (r = −0.04, p = 0.81); however, there was a strong significant correlation between ADH and water loss (r = 0.74, p < 0.001). Multinomial logistic regression showed no association between fractographic feature expression and ADH or collagen percentage. In conclusion, forensic fractographic features reliably determine initiation and directionality of crack propagation in experimentally induced PMIs up to 40,600 ADH, demonstrating the utility of this method into the recent postmortem interval. This expression of reliable fractographic features throughout the early PMI intimates these characteristics may not be useful standalone features for discerning peri‐ versus postmortem fractures.
Promoting Neuronal Outgrowth Using Ridged Scaffolds Coated with Extracellular Matrix Proteins
Siddiqui, Ahad M. , Brunner, Rosa, Harris, Greg M. , Miller, A. Lee , Waletzki, Brian E., Schmeichel, Ann M., Schwarzbauer, Jean E. , Yaszemski, Michael J. , Windebank, Anthony J. , Madigan, Nicolas N. , Harris, Gregory M , Miller, Alan Lee , Madigan, Nicolas N , Schwartz, Jeffrey

Biomedicines | April 27, 2021 | Volume: 9 | Issue: 5 | Pages: 479

10.3390/biomedicines9050479 Get It

Spinal cord injury (SCI) results in cell death, demyelination, and axonal loss. The spinal cord has a limited ability to regenerate, and current clinical therapies for SCI are not effective in helping promote neurologic recovery. We have developed a novel scaffold biomaterial that is fabricated from the biodegradable hydrogel oligo(poly(ethylene glycol)fumarate) (OPF). We have previously shown that positively charged OPF scaffolds (OPF+) in an open spaced, multichannel design can be loaded with Schwann cells to support axonal generation and functional recovery following SCI. We have now developed a hybrid OPF+ biomaterial that increases the surface area available for cell attachment and that contains an aligned microarchitecture and extracellular matrix (ECM) proteins to better support axonal regeneration. OPF+ was fabricated as 0.08 mm thick sheets containing 100 μm high polymer ridges that self-assemble into a spiral shape when hydrated. Laminin, fibronectin, or collagen I coating promoted neuron attachment and axonal outgrowth on the scaffold surface. In addition, the ridges aligned axons in a longitudinal bipolar orientation. Decreasing the space between the ridges increased the number of cells and neurites aligned in the direction of the ridge. Schwann cells seeded on laminin coated OPF+ sheets aligned along the ridges over a 6-day period and could myelinate dorsal root ganglion neurons over 4 weeks. This novel scaffold design, with closer spaced ridges and Schwann cells, is a novel biomaterial construct to promote regeneration after SCI.
Injectable Electrical Conductive and Phosphate Releasing Gel with Two-Dimensional Black Phosphorus and Carbon Nanotubes for Bone Tissue Engineering
Liu, Xifeng , George, Matthew N. , Li, Linli , Gamble, Darian, Gaihre, Bipin , Waletzki, Brian E., Lu, Lichun , Miller Ii, A Lee, Lu, Lichun , Miller, Alan Lee

ACS Biomaterials Science & Engineering | June 25, 2020 | Volume: 6 | Issue: 8 | Pages: 4653-4665

10.1021/acsbiomaterials.0c00612 Get It

3D bioprinting of oligo(poly[ethylene glycol] fumarate) for bone and nerve tissue engineering
Liu, Xifeng , Gaihre, Bipin , George, Matthew N. , Miller, A. Lee , Xu, Haocheng , Waletzki, Brian E., Lu, Lichun , Miller, Alan Lee

Journal of Biomedical Materials Research Part A | May 17, 2020 | Volume: 109 | Issue: 1 | Pages: 6-17

10.1002/jbm.a.37002 Get It

Abstract3D bioprinting is a promising new tissue restoration technique that enables the precise deposition of cells and growth factors in order to more closely mimic the structure and function of native organs. In this study, we report the development of a new bioink using oligo(poly[ethylene glycol] fumarate) (OPF), a photo‐crosslinkable, and biodegradable polymer, for 3D bioprinting. In addition to OPF, a small portion of gelatin was also incorporated into the bioink to make it bio‐printable. After immersion in the cell medium, gelatin was eluted away to create a bioprinted scaffold of pure OPF. Excellent cell viability, spreading, and long‐term proliferation of encapsulated cells was observed using both bone and nerve cells as examples. These results demonstrate that OPF bioink has great potential in future 3D bioprinting applications that aim to replicate complex, layered tissues, and/or organs.
Injectable Catalyst-Free Poly(Propylene Fumarate) System Cross-Linked by Strain Promoted Alkyne–Azide Cycloaddition Click Chemistry for Spine Defect Filling
Liu, Xifeng , Xu, Hao , Waletzki, Brian E., Lu, Lichun , Miller, A. Lee , Lu, Lichun , Miller, Alan Lee

Biomacromolecules | August 9, 2019 | Volume: 20 | Issue: 9 | Pages: 3352-3365

10.1021/acs.biomac.9b00133 Get It

Effect of Direct Electrical Current on Bones Infected with Staphylococcus epidermidis
Schmidt-Malan, Suzannah M., Brinkman, Cassandra L., Karau, Melissa J. , Brown, Robert A. , Waletzki, Brian E., Berglund, Lawrence J., Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Schuetz, Audrey N.

JBMR Plus | October 29, 2018 | Volume: 3 | Issue: 5 | Pages: No page available

10.1002/jbm4.10119 Get It

ABSTRACTWe are developing electrical approaches to treat biofilm‐associated orthopedic foreign‐body infection. Although we have previously shown that such approaches have antibiofilm activity, the effects on bone have not been assessed. Herein, low‐amperage 200 μA fixed direct current (DC) was compared with no current, in a rat femoral foreign‐body infection model. In the infected group, a platinum implant seeded with S. epidermidis biofilm (105 CFU/cm2), plus 50 μL of a 109 CFU suspension of bacteria, were placed in the femoral medullary cavity of 71 rats. One week later, rats were assigned to one of four groups: infected with no current or DC, or uninfected with no current or DC. After 2 weeks, bones were removed and subjected to histopathology, micro‐computed tomography (μCT), and strength testing. Histopathology showed no inflammation or bony changes/remodeling in the uninfected no current group, and some osteoid formation in the DC group; bones from the infected no current group had evidence of inflammation without bony changes/remodeling; along with inflammation, there was moderate osteoid present in the DC group. μCT showed more cortical bone volume and density, trabecular thickness, and cancellous bone volume in the DC group compared with the no current group, for both uninfected and infected bones (p < 0.05). There was no difference in torsional strength or stiffness between the no current versus DC groups, for both infected and uninfected bones (p > 0.05). © 2018 The Authors. JBMR Plus Published by Wiley Periodicals, Inc. on behalf of the American Society for Bone and Mineral Research.
Electrically conductive nanocomposite hydrogels embedded with functionalized carbon nanotubes for spinal cord injury
Liu, Xifeng , Kim, Joseph C. , Waletzki, Brian E., Lu, Lichun , Miller, Alan Lee

New Journal of Chemistry | September 18, 2018 | Volume: 42 | Issue: 21 | Pages: 17671-17681

10.1039/c8nj03038c Get It

Electrically conductive hydrogels incorporated with CNTs support PC12 cell growth and differentiation and hold promise for nerve regeneration.
Establishing a Current Good Manufacturing Practice Facility for Biomaterials and Biomolecules in an Academic Medical Center
Greenberg, Alexandra J. , Runge, Bethany Kinseth, Solyntjes, Sarah A., Helene-Kraft, Juliana St., Glass, Suzanne L., Waletzki, Brian E., Herrick, James L., Yaszemski, Michael J. , Windebank, Anthony J. , Wang, Huan , Greenberg-Worisek, Alexandra J, St Helene-Kraft, Juliana, Miller, Alan Lee, Miller, Alan Lee , Wang, Huan

Tissue Engineering Part B: Reviews | August 7, 2018 | Volume: 24 | Issue: 6 | Pages: 493-498

10.1089/ten.teb.2018.0114 Get It

Poly(Propylene Fumarate)–Hydroxyapatite Nanocomposite Can Be a Suitable Candidate for Cervical Cages
Teng, Yong, Giambini, Hugo , Rezaei, Asghar , Liu, Xifeng , Waletzki, Brian E., Lu, Lichun , Miller, Alan Lee

Journal of Biomechanical Engineering | July 20, 2018 | Volume: 140 | Issue: 10 | Pages: No page available

10.1115/1.4040458 Get It

A wide range of materials have been used for the development of intervertebral cages. Poly(propylene fumarate) (PPF) has been shown to be an excellent biomaterial with characteristics similar to trabecular bone. Hydroxyapatite (HA) has been shown to enhance biocompatibility and mechanical properties of PPF. The purpose of this study was to characterize the effect of PPF augmented with HA (PPF:HA) and evaluate the feasibility of this material for the development of cervical cages. PPF was synthesized and combined with HA at PPF:HA wt:wt ratios of 100:0, 80:20, 70:30, and 60:40. Molds were fabricated for testing PPF:HA bulk materials in compression, bending, tension, and hardness according to ASTM standards, and also for cage preparation. The cages were fabricated with and without holes and with porosity created by salt leaching. The samples as well as the cages were mechanically tested using a materials testing frame. All elastic moduli as well as the hardness increased significantly by adding HA to PPF (p < 0.0001). The 20 wt % HA increased the moduli significantly compared to pure PPF (p < 0.0001). Compressive stiffness of all cages also increased with the addition of HA. HA increased the failure load of the porous cages significantly (p = 0.0018) compared with nonporous cages. PPF:HA wt:wt ratio of 80:20 proved to be significantly stiffer and stronger than pure PPF. The current results suggest that this polymeric composite can be a suitable candidate material for intervertebral body cages.
Cross‐linkable graphene oxide embedded nanocomposite hydrogel with enhanced mechanics and cytocompatibility for tissue engineering
Liu, Xifeng , Miller, A. Lee , Waletzki, Brian E., Lu, Lichun , Miller, Alan Lee

Journal of Biomedical Materials Research Part A | December 27, 2017 | Volume: 106 | Issue: 5 | Pages: 1247-1257

10.1002/jbm.a.36322 Get It

AbstractGraphene oxide (GO) is an attractive material that can be utilized to enhance the modulus and conductivities of substrates and hydrogels. To covalently cross‐link graphene oxide sheets into hydrogels, abundant cross‐linkable double bonds were introduced to synthesize the graphene‐oxide‐tris‐acrylate sheet (GO‐TrisA). Polyacrylamide (PAM) nanocomposite hydrogels were then fabricated with inherent covalently and permanently cross‐linked GO‐TrisA sheets. Results showed that the covalently cross‐linked GO‐TrisA/PAM nanocomposite hydrogel had enhanced mechanical strength, thermo stability compared with GO/PAM hydrogel maintained mainly by hydrogen bonding between PAM chains and GO sheets. In vitro cell study showed that the covalently cross‐linked rGO‐TrisA/PAM nanocomposite hydrogel had excellent cytocompatibility after in situ reduction. These results suggest that rGO‐TrisA/PAM nanocomposite hydrogel holds great potential for tissue engineering applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1247–1257, 2018.