Back to Authors

Patel, Nilay

https://orcid.org/0000-0002-0799-1922

Mayo Clinic

Saint Peter's University Hospital

Citations 23

Multivessel Percutaneous Coronary Interventions in the United States
Arora, Shilpkumar , Panaich, Sidakpal , Patel, Nileshkumar , Patel, Nilay , Solanki, Shantanu , Deshmukh, Abhishek , Singh, Vikas , Lahewala, Sopan , Savani, Chirag, Thakkar, Badal, Dave, Abhishek , Patel, Achint , Bhatt, Parth , Sonani, Rajesh, Patel, Aashay, Cleman, Michael , Forrest, John K. , Schreiber, Theodore , Badheka, Apurva O., Grines, Cindy L. , Panaich, Sidakpal S

Angiology | July 5, 2015 | Volume: 67 | Issue: 4 | Pages: 326-335

10.1177/0003319715593853 Get It

Background: Multivessel coronary artery disease carries significant mortality risk. Comprehensive data on inhospital outcomes following multivessel percutaneous coronary intervention (MVPCI) are sparse. Methods: We queried the Healthcare Cost and Utilization Project’s nationwide inpatient sample (NIS) between 2006 and 2011 using different International Classification of Diseases, 9th Revision, Clinical Modification procedure codes. The primary outcome was inhospital all-cause mortality, and the secondary outcome was a composite of inhospital mortality and periprocedural complications. Results: The overall mortality was low at 0.73% following MVPCI. Multivariate analysis revealed that (odds ratio, 95% confidence interval, P value) age (1.63, 1.48-1.79; <.001), female sex (1.19, 1.00-1.42; P = .05), acute myocardial infarction (AMI; 2.97, 2.35-3.74; <.001), shock (17.24, 13.61-21.85; <.001), a higher burden of comorbidities (2.09, 1.32-3.29; .002), and emergent/urgent procedure status (1.67, 1.30-2.16; <.001) are important predictors of primary and secondary outcomes. MVPCI was associated with higher mortality, length of stay (LOS), and cost of care as compared to single vessel single stent PCI. Conclusion: MVPCI is associated with higher inhospital mortality, LOS, and hospitalization costs compared to single vessel, single stent PCI. Higher volume hospitals had lower overall postprocedural mortality rate along with shorter LOS and lower hospitalization costs following MVPCI.
Variability in utilization of drug eluting stents in United States: Insights from nationwide inpatient sample
Panaich, Sidakpal , Badheka, Apurva O., Arora, Shilpkumar , Patel, Nileshkumar , Thakkar, Badal, Patel, Nilay , Singh, Vikas , Chothani, Ankit , Deshmukh, Abhishek , Agnihotri, Kanishk, Jhamnani, Sunny , Lahewala, Sopan , Manvar, Sohilkumar, Panchal, Vinaykumar , Patel, Achint , Bhatt, Parth , Savani, Chirag, Savani, Ghanshyambhai T., Solanki, Shantanu , Patel, Samir , Kaki, Amir , Mohamad, Tamam , Elder, Mahir, Kondur, Ashok , Cleman, Michael , Forrest, John K. , Schreiber, Theodore , Patel, Neil S , Patel, Jay N. , Grines, Cindy L. , Panaich, Sidakpal S

Catheterization and Cardiovascular Interventions | May 29, 2015 | Volume: 87 | Issue: 1 | Pages: 23-33

10.1002/ccd.25977 Get It

ObjectivesWe studied the trends and predictors of drug eluting stent (DES) utilization from 2006 to 2011 to further expound the inter‐hospital variability in their utilization.BackgroundWe queried the Healthcare Cost and Utilization Project's Nationwide Inpatient Sample (NIS) between 2006 and 2011 using ICD‐9‐CM procedure code, 36.06 (bare metal stent) or 36.07 (drug eluting stents) for Percutaneous Coronary Intervention (PCI). Annual hospital volume was calculated using unique identification numbers and divided into quartiles for analysis.Methods and ResultsWe built a hierarchical two level model adjusted for multiple confounding factors, with hospital ID incorporated as random effects in the model. About 665,804 procedures (weighted n = 3,277,884) were analyzed. Safety concerns arising in 2006 reduced utilization DES from 90% of all PCIs performed in 2006 to a nadir of 69% in 2008 followed by increase (76% of all stents in 2009) and plateau (75% in 2011). Significant between‐hospital variation was noted in DES utilization irrespective of patient or hospital characteristics. Independent patient level predictors of DES were (OR, 95% CI, P‐value) age (0.99, 0.98–0.99, <0.001), female(1.12, 1.09–1.15, <0.001), acute myocardial infarction(0.75, 0.71–0.79, <0.001), shock (0.53, 0.49–0.58, <0.001), Charlson Co‐morbidity index (0.81,0.77–0.86, <0.001), private insurance/HMO (1.27, 1.20–1.34, <0.001), and elective admission (1.16, 1.05–1.29, <0.001). Highest quartile hospital (1.64, 1.25–2.16, <0.001) volume was associated with higher DES placement.ConclusionThere is significant between‐hospital variation in DES utilization and a higher annual hospital volume is associated with higher utilization rate of DES. © 2015 Wiley Periodicals, Inc.
Influence of hospital volume on outcomes of percutaneous atrial septal defect and patent foramen ovale closure: A 10‐years us perspective
Singh, Vikas , Badheka, Apurva O., Patel, Nileshkumar, Chothani, Ankit , Mehta, Kathan , Arora, Shilpkumar , Patel, Nilay , Deshmukh, Abhishek , Shah, Neeraj , Savani, Ghanshyambhai T., Manvar, Sohilkumar, Thakkar, Badal, Panchal, Vinaykumar , Palacios, Igor F. , Rihal, Charanjit S. , Cohen, Mauricio G. , Marchena, Eduardo de , Rathod, Ankit D. , Patel, Jay N. , Rihal, Charanjit S. , O’Neill, William W. , Cohen, Mauricio G

Catheterization and Cardiovascular Interventions | December 22, 2014 | Volume: 85 | Issue: 6 | Pages: 1073-1081

10.1002/ccd.25794 Get It

Background: Contemporary data regarding percutaneous closure of atrial septal defect/patent foramen ovale (ASD/PFO) are lacking. We evaluated the current trends in utilization of ASD/PFO closure in adults and investigated the effect of annual hospital volume on in‐hospital outcomes. Methods: We queried the Nationwide Inpatient Sample between the years 2001 and 2010 using the International Classification of Diseases (ICD‐9‐CM) procedure code for percutaneous closure of ASD/PFO with device. Hierarchical mixed effects models were generated to identify the independent multivariate predictors of outcomes. Results: A total of 7,107 percutaneous ASD/PFO closure procedures (weighted n = 34,992) were available for analysis. A 4.7‐fold increase in the utilization of this procedure from 3/million in 2001 to 14/million adults in 2010 in US (P < 0.001) was noted. Overall, percutaneous ASD/PFO closure was associated with 0.5% mortality and 12% in‐hospital complications. The utilization of intracardiac echocardiography (ICE) increased 15 fold (P < 0.001) during the study period. The procedures performed at the high volume hospitals [2nd (14–37 procedures/year) and 3rd (>38 procedures/year) tertile] were associated with significant reduction in complications, length of stay and cost of hospitalization when compared to those performed at lowest volume centers (<13 procedures/year). Majority (70.5%) of the studied hospitals were found to be performing <10 procedures/year hence deviating from the ACC/AHA/SCAI clinical competency guidelines. Conclusions: Low hospital volume is associated with an increased composite (mortality and procedural complications) adverse outcome following ASD/PFO closure. In the interest of patient safety, implementation of the current guidelines for minimum required annual hospital volume to improve clinical outcomes is warranted. © 2014 Wiley Periodicals, Inc.