Back to Authors

Kodali, Susheel

https://orcid.org/0000-0003-0517-2074

Mayo Clinic

Columbia University Irving Medical Center

Citations 22

Costs of Periprocedural Complications in Patients Treated With Transcatheter Aortic Valve Replacement
Lei, Yang , Reynolds, Matthew R. , Magnuson, Elizabeth A. , Suri, Rakesh M. , Tuzcu, E. Murat , Petersen, John L., Douglas, Pamela S. , Svensson, Lars G. , Gada, Hemal, Thourani, Vinod H. , Kodali, Susheel , Mack, Michael J. , Leon, Martin B. , Arnold, Suzanne V. , Cohen, David Jonathan , Douglas, Pamela S

Circulation: Cardiovascular Interventions | October 22, 2014 | Volume: 7 | Issue: 6 | Pages: 829-836

10.1161/circinterventions.114.001395 Get It

Background— In patients with severe aortic stenosis, transcatheter aortic valve replacement (TAVR) improves survival when compared with nonsurgical therapy but with higher in-hospital and lifetime costs. Complications associated with TAVR may decrease with greater experience and improved devices, thereby reducing the overall cost of the procedure. Therefore, we sought to estimate the effect of periprocedural complications on in-hospital costs and length of stay of TAVR. Methods and Results— Using detailed cost data from 406 TAVR patients enrolled in the Placement of Aortic Transcatheter Valve (PARTNER) I trial, we developed multivariable models to estimate the incremental cost and length of stay associated with specific periprocedural complications. Attributable costs and length of stay for each complication were calculated by multiplying the independent cost of each event by its frequency in the treatment group. Mean cost for the initial hospitalization was $79 619±40 570 ($50 891 excluding the valve); 49% of patients had ≥1 complication. Seven complications were independently associated with increased hospital costs, with major bleeding, arrhythmia, and death accounting for the largest attributable cost per patient. Renal failure and the need for repeat TAVR, although less frequent, were also associated with substantial incremental and attributable costs. Overall, complications accounted for $12 475 per patient in initial hospital costs and 2.4 days of hospitalization. Conclusions— In the PARTNER trial, periprocedural complications were frequent, costly, and accounted for ≈25% of non-implant–related hospital costs. Avoidance of complications should improve the cost-effectiveness of TAVR for inoperable and high-risk patients, but reductions in the cost of uncomplicated TAVR will also be necessary for optimal efficiency. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.
Impact of Aortic Annulus Size on Valve Hemodynamics and Clinical Outcomes After Transcatheter and Surgical Aortic Valve Replacement
Rodés‐Cabau, Josep , Pîbarot, Philippe , Suri, Rakesh M. , Kodali, Susheel , Thourani, Vinod H. , Szeto, Wilson Y. , Svensson, Lars G. , Dumont, Éric , Xu, Ke , Leon, Martin B. , Douglas, Pamela S. , Pibarot, Phillippe , Hahn, Rebecca T , Douglas, Pamela S

Circulation: Cardiovascular Interventions | October 1, 2014 | Volume: 7 | Issue: 5 | Pages: 701-711

10.1161/circinterventions.114.001681 Get It

Background— The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. Methods and Results— Patients included the randomized controlled trial (n=574) and nonrandomized continued access (n=1358) cohorts were divided in tertiles according to aortic annulus diameter (small aortic annulus tertile, medium aortic annulus tertile, and large aortic annulus tertile [LAA], respectively) as measured by transthoracic echocardiography. Severe prosthesis–patient mismatch was defined as an effective aortic orifice area of <0.65 cm 2 /m 2 . In the randomized controlled trial cohort, patients in the small aortic annulus tertile who underwent transcatheter aortic valve replacement had a lower incidence of severe prosthesis–patient mismatch (19.7% versus 37.5%; P =0.03) and only a trend toward a higher incidence of moderate-to-severe paravalvular leaks compared with surgical aortic valve replacement (5.7% versus 0%; P =0.06). In the LAA tertile, there were no differences in the rate of prosthesis–patient mismatch between groups, and a significant increase in moderate-to-severe paravalvular leaks was associated with transcatheter aortic valve replacement (9% versus 0%; P =0.01). There were no differences in mortality between transcatheter aortic valve replacement and surgical aortic valve replacement. In the nonrandomized continued access cohort, there were no differences in prosthesis–patient mismatch between the small aortic annulus and LAA tertiles, but a higher rate of moderate-to-severe paravalvular leaks was observed in the LAA tertile (5.9% versus 11.5%; P =0.009). Patients in the LAA tertile had a higher mortality rate at 1-year follow-up ( P =0.02), and differences persisted in multivariable analysis ( P =0.048 for LAA versus medium aortic annulus tertile, P =0.035 for LAA versus small aortic annulus tertile). Conclusions— Aortic annulus size had a major impact on valve hemodynamics and clinical outcomes after transcatheter aortic valve replacement and surgical aortic valve replacement. This study highlights the importance of considering aortic annulus size in the evaluation of high-risk patients who are candidates for aortic valve replacement. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.