Back to Authors

Cha, Yong‐Mei

https://orcid.org/0000-0002-5897-9464

Mayo Clinic

Mayo Clinic

Citations 164

Performance of an Automatic Arrhythmia Classification Algorithm: Comparison to the ALTITUDE Electrophysiologist Panel Adjudications
Mahajan, Deepa, Dong, Yanting , Saxon, Leslie A. , Cha, Yong‐Mei , Gilliam, F. Roosevelt, Asirvatham, Samuel J. , Cesario, David A., Jones, Paul W. , Seth, Milan, Powell, Brian D. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 17, 2014 | Volume: 37 | Issue: 7 | Pages: 889-899

10.1111/pace.12367 Get It

IntroductionAdjudication of thousands of implantable cardioverter defibrillator (ICD)‐treated arrhythmia episodes is labor intensive and, as a result, is most often left undone. The objective of this study was to evaluate an automatic classification algorithm for adjudication of ICD‐treated arrhythmia episodes.MethodsThe algorithm uses a machine learning algorithm and was developed using 776 arrhythmia episodes. The algorithm was validated on 131 dual‐chamber ICD shock episodes from 127 patients adjudicated by seven electrophysiologists (EPs). Episodes were classified by panel consensus as ventricular tachycardia/ventricular fibrillation (VT/VF) or non‐VT/VF, with the resulting classifications used as the reference. Subsequently, each episode electrogram (EGM) data was randomly assigned to three EPs without the atrial lead information, and to three EPs with the atrial lead information. Those episodes were also classified by the automatic algorithm with and without atrial information. Agreement with the reference was compared between the three EPs consensus group and the algorithm.ResultsThe overall agreement with the reference was similar between three‐EP consensus and the algorithm for both with atrial EGM (94% vs 95%, P = 0.87) and without atrial EGM (90% vs 91%, P = 0.91). The odds of accurate adjudication, after adjusting for covariates, did not significantly differ between the algorithm and EP consensus (odds ratio 1.02, 95% confidence interval: 0.97–1.06).ConclusionsThis algorithm performs at a level comparable to an EP panel in the adjudication of arrhythmia episodes treated by both dual‐ and single‐chamber ICDs. This type of algorithm has the potential for automated analysis of clinical ICD episodes, and adjudication of EGMs for research studies and quality analyses.
Distinguishing Ventricular Arrhythmia Originating from the Right Coronary Cusp, Peripulmonic Valve Area, and the Right Ventricular Outflow Tract: Utility of Lead I
Ebrille, Elisa , Chandra, Vishnu , Syed, Faisal F. , Muñoz, Freddy Del Carpio, Nanda, Sudip , Hai, Jo Jo , Cha, Yong‐Mei , Friedman, Paul A. , Hammill, Stephen C., Munger, Thomas M. , Venkatachalam, K, Packer, Douglas L. , Asirvatham, Samuel J. , Syed, Faisal, Del Carpio Munoz, Freddy, Munoz, Freddy Del‐Carpio , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | November 25, 2013 | Volume: 25 | Issue: 4 | Pages: 404-410

10.1111/jce.12330 Get It

ECG Lead I and Outflow Tract ArrhythmiaIntroductionOutflow tract ventricular arrhythmia (OTVA) can be complicated to target for ablation when originating from either the periaortic or pulmonary valve (PV) region. Both sites may present with a small R wave in lead V1. However, the utility of lead I in distinguishing these arrhythmia locations is unknown.Methods and ResultsThirty‐six consecutive patients (mean age 41 ± 14 years, 13 male) underwent catheter ablation for OTVA. OTVA origin was determined from intracardiac electrogram tracings and electroanatomic maps. Observers blinded to results measured QRS waveform amplitude and duration from standard 12‐lead ECG tracings. Measurements with highest diagnostic performance were modeled into an algorithm. Sites of successful ablation were anterior right ventricular outflow tract (RVOT; n = 6), posterior RVOT (n = 4), PV (n = 18), and right coronary cusp (RCC; n = 8). Highest performing surface ECG discriminators were from lead I to V1 vectors: RCC, lead I R wave ≥ 1.5 mV, and V1 R wave ≥2.0 mV (sensitivity 87%, specificity 93%); PV, V1 R wave > 0 mV, and lead I R/(R+S) ≤ 0.75 (sensitivity 78%, specificity 72%); anterior RVOT, V1 R wave = 0 mV, and lead I R/(R+S) <0.4 (sensitivity 67%, specificity 97%); posterior RVOT, V1 R wave > 0 mV, and lead I R/(R+S) > 0.75 (sensitivity 75%, specificity 84%). Sequential algorithmic application of these criteria resulted in an overall accuracy of 72% in predicting site of OTVA origin.ConclusionsA relatively large R wave in lead I is seen with RCC origin but not PV origin. A sequential algorithm has limited but potentially significant value beyond assessment of lead I in approaching OTVA.
e0624 The effect of cardiac resynchronisation therapy on novel neurohormones in heart failure
Dong, Yun-xu, Burnett, J.C., Chen, H. H., Sandberg, S. M., Zhang, Yanhua, Chen, P.-S., Cha, Yong‐Mei , Sandberg, Sharon M., Zhang, Yanhua

Heart | September 12, 2013 | Volume: 96 | Issue: Suppl 3 | Pages: A192.3-A192

10.1136/hrt.2010.208967.624 Get It

Background Neurohormonal dysregulation contributes to heart failure (HF) progression. We sought to determine the effect of cardiac resynchronisation therapy (CRT) on the nerve growth factor (NGF), a biomarker that promotes the maturation, and survival of sympathetic nerve endings, and amino-terminal propeptide of type III procollagen (PIIINP), a marker of type III collagen synthesis. Methods This prospective study enrolled 20 healthy age-matched controls and 45 consecutive patients (pts) who received CRT-D. NYHA class, distance of 6-min walk and echocardiography and plasma concentrations of NGF, PIIINP, b-type natriuretic peptide (BNP), norepinephrine (NE), epinephrine (EPI) and dopamine (DA) were measured before and 6 month after CRT. Response to CRT was defined as ≥15% reduction in left ventricular end-systolic volume index (LVESVI) at 6-month follow-up. Results The baseline BNP (557±692 vs 47±35, p<0.01) and PIIINP (8.22±3.76 vs 5.36±1.47, p<0.01) were elevated in HF compared to controls, while NGF, NE, EPI and DA levels were not different. Twenty two of 45 pts (49%) responded to CRT. The responder group demonstrated significant decrease only in BNP level (p=0.04) at 6-month follow-up, parallelling with the clinical improvements (table 1). The baseline PIIINP was lower in CRT responders than non-responders (p=0.04), and it correlated with the reduction of LVESVI (p=0.01, r=−0.50) after CRT. The further multivariate analysis showed only the plasma PIIINP level among clinic characters and all the biomarkers can predict the improvement of LVESV index (OR=8.33, P=0.01). Conclusion The low PIIINP level, which is consistent with possible less cardiac fibrosis and a more plastic ventricle at baseline, is associated with CRT responsiveness. Contrary to previous reports, the NGF levels were not reduced during HF and that there was no NGF rebound in CRT responders.
Magnetic Resonance Imaging in Patients with Recently Implanted Pacemakers
Friedman, Hannah, Acker, Nancy, Dalzell, Connie, Shen, Win K., Asirvatham, Samuel J. , Cha, Yong‐Mei , Hodge, David O. , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Friedman, Hannah L, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1090-1095

10.1111/pace.12213 Get It

BackgroundRecent studies have shown that magnetic resonance imaging (MRI) of patients with pacemakers can be safely performed under careful monitoring, but they excluded patients with recently implanted devices. Patients with recent implants may be at a greater risk for complications during MRI imaging due to lack of lead and wound maturity.MethodsWe implemented a clinical protocol for MRI imaging of patients with implanted cardiac devices, and prospectively collected data. For this study, we retrospectively analyzed two groups of patients: those with recently implanted (≤42 days) and nonrecently implanted (>42 days) leads at the time of MRI scanning. All devices were interrogated before and after scanning, and were reprogrammed during the scan as per protocol.ResultsOf the 219 scans (in 171 patients), eight included patients with recently implanted (range: 7–36 days) and 211 with only nonrecently implanted pacemaker leads. During the scan, there were no complications in the early or late group. In one patient imaged 79 days postimplant, frequent premature ventricular complexes were noted during the scan, requiring no action. No patient reported pain during or immediately after the procedure. No clinically significant changes in function were seen at subsequent follow up (average 104 days post‐MRI). Compared to patients with nonrecently implanted leads, there was no difference in any parameter between the two groups.ConclusionsWith a strong clinical indication and with careful monitoring, MRI imaging is feasible in patients with recently implanted pacemakers, although experience is limited.
Cardiac Device Complications in the Cognitively Impaired
Jama, Abdi, Hodge, David O. , Herges, Regina M., Asirvatham, Samuel, Cha, Yong‐Mei , Powell, Brian D. , Rea, Robert F., Friedman, Paul A. , Asirvatham, Samuel J. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1061-1067

10.1111/pace.12205 Get It

BackgroundPatients with preexisting mild cognitive impairment or dementia may be at increased risk for developing cardiac device complications due to an impaired ability to follow postimplant care instructions. We sought to determine whether rates of infection, lead dislodgement, or appropriate or inappropriate implantable cardioverter defibrillator (ICD) shocks are increased in this population.MethodsMedical charts of 561 patients with mild cognitive impairment or dementia who underwent pacemaker (PM) or ICD implantation between January 2002 and October 2009 at Mayo Clinic were identified. A total of 134 patients who were diagnosed with cognitive impairment or dementia before device implantation or within 1 year of implantation were compared with 134 matched controls. Information was collected on patient characteristics, comorbid medical conditions, ejection fraction, complications, device type, device therapy, and mortality. Device information was prospectively entered into a database and retrospectively reviewed.ResultsOf the 134 patients with mild cognitive impairment and dementia, 99 underwent PM implantation and 35 underwent ICD implantation. Compared to controls, there was no difference in patient characteristics, ejection fraction, or comorbidities except for diabetes, which was more prevalent in the cognitively impaired and demented group (18.7% vs 30.6%, P = 0.02). There was no difference in device therapy and complications (14.4% vs 5.8%, P = 0.268). However, there was a decreased survival in patients with cognitive impairment and dementia when compared to the control group (42% vs 67% at 5 years, P = 0.007).ConclusionPatients with cognitive impairment and standard device indications are not at increased risk for device complications and therapy but their survival is much lower than in matched controls. The cause of this lower survival is unknown but may be related to the underlying neurological disease. Presence of cognitive impairment should therefore be considered when contemplating implantation of a cardiac device.
Outcomes of Cardiac Resynchronization Therapy in the Elderly
Killu, Ammar M. , WU, JIA‐HUI, Friedman, Paul A. , Shen, Win-Kuang, Webster, Tracy L., Brooke, Kelly L., Hodge, David O. , Wiste, Heather J. , Cha, Yong‐Mei

Pacing and Clinical Electrophysiology | December 18, 2012 | Volume: 36 | Issue: 6 | Pages: 664-672

10.1111/pace.12048 Get It

BackgroundOctogenarians (>80 years) have been underrepresented in clinical trials of cardiac resynchronization therapy (CRT).ObjectiveTo determine the benefit of CRT with or without a defibrillator in older elderly patients.MethodsWe retrospectively studied consecutive patients who received CRT at our institution from 2002 through 2008. New York Heart Association (NYHA) class and echocardiographic parameters were assessed before and after CRT. Thirty‐day complications after device implant were collected. Survival data were obtained from the national death and location database. Data were compared between those 80 years and younger and those older than 80 years.ResultsOf 728 patients identified, 90 (12.4%) were older than 80 years. After CRT, older and younger patients had similar improvements in NHYA class (P = 0.41), ejection fraction (P = 0.48), and mitral valve regurgitation (MR) severity (P = 0.42). In the older patients, defibrillator implantation was associated with comparable improvement in NYHA class, ejection fraction, and MR grade severity (P > 0.05), as in those without a defibrillator. Overall survival was worse in octogenarians than in the younger patients by Kaplan‐Meier estimates (P = 0.001). Multivariate analysis showed similar survival between the younger and older subjects (hazard ratio, 1.23; 95% confidence interval, 0.83–1.84; P = 0.31). The observed complication rate in all study subjects was 12.2%, with no difference between the two age groups.ConclusionOctogenarian patients who received CRT with or without a defibrillator for advanced heart failure had similar clinical benefits as younger patients. CRT should not be withheld from octogenarians meeting current selection guidelines.
Left Ventricular Discoordination Index Measured by Speckle Tracking Strain Rate Imaging Predicts Reverse Remodelling and Survival After Cardiac Resynchronization Therapy
Wang, Chun‐Li, Powell, Brian D. , Redfield, Margaret M. , Miyazaki, Chinami , Olson, Lyle J. , Cha, Yong‐Mei , Espinosa, Raúl E. , Hayes, David L. , Hodge, David O. , Lin, Grace , Friedman, Paul A. , Oh, Jae K. , Fine, Nowell Mark

European Journal of Heart Failure | March 12, 2012 | Volume: 14 | Issue: 5 | Pages: 517-525

10.1093/eurjhf/hfs025 Get It

Abstract Aims This study aimed to evaluate the predictive value of a baseline speckle tracking strain rate imaging-derived discoordination index for response to cardiac resynchronization therapy (CRT). Methods and results Ninety-seven patients with QRS ≥120 ms and left ventricular (LV) ejection fraction ≤35% were prospectively followed after CRT in the Mayo CRT Registry. The LV discoordination index (stretch/shortening or thinning/thickening during ejection) was calculated from three types of deformation, radial, circumferential, and longitudinal, using two-dimensional speckle tracking strain rate imaging. The benefit of CRT was evaluated by reverse remodelling (i.e. reduction of LV end-systolic volume ≥15% at 6-month follow-up) and survival. The optimal cut-off value of the baseline discoordination index in discriminating responders from non-responders was determined by receiver operating characteristic curve analysis. Significant differences in baseline indices between responders and non-responders were noted for radial and circumferential discoordination indices. A mid-ventricular radial discoordination index (RDI-M) &gt;38% best predicted responders, especially in patients with ischaemic cardiomyopathy (area under the curve 0.86 for all patients, sensitivity 80%, and specificity 91%). Death occurred in 28 patients over a median follow-up of 3.2 years. When adjusted for confounding variables, lack of significant discoordination (RDI-M &lt;38%) before CRT was associated with a particularly high mortality (hazard ratio 7.05, 95% confidence interval 2.45–26.0). Conclusion LV discoordination assessed by speckle tracking RDI-M imaging was able to predict reverse remodelling at 6 months and survival of patients who received CRT.
Premature Ventricular Contraction-Induced Cardiomyopathy
Cha, Yong‐Mei , Lee, Glenn K., Klarich, Kyle W. , Grogan, Martha

Circulation: Arrhythmia and Electrophysiology | February 14, 2012 | Volume: 5 | Issue: 1 | Pages: 229-236

10.1161/circep.111.963348 Get It

Cardiac Sympathetic Reserve and Response to Cardiac Resynchronization Therapy
Cha, Yong‐Mei , Dong, Ying-Xue, Kemp, Bradley J. , Oh, Jae K. , Miyazaki, Chinami , Hayes, David L. , Rea, Robert F., Asirvatham, Samuel J. , Webster, Tracy L., Dalzell, Connie, Hodge, David O. , Herges, Regina M., Yong, Yan-zhong, Zhang, Yanhua, Chen, Peng‐Sheng , Chareonthaitawee, Panithaya , Zhang, Yanhua, Asirvatham, Samuel J

Circulation: Heart Failure | March 19, 2011 | Volume: 4 | Issue: 3 | Pages: 339-344

10.1161/circheartfailure.110.959858 Get It

Background— The objective of the present study was to investigate the effect of cardiac resynchronization therapy (CRT) on cardiac autonomic function. Methods and Results— This prospective study included 45 consecutive patients with heart failure who received CRT devices with defibrillator and 20 age-matched, healthy control subjects. At baseline and 3 months and 6 months after CRT, we assessed New York Heart Association (NYHA) class, 6-minute walk distance, plasma sympathetic biomarker nerve growth factor, echocardiography, heart rate variability and cardiac presynaptic sympathetic function determined by iodine 123 metaiodobenzylguanidine scintigraphy. After CRT, NYHA class improved by 1 class ( P <0.001), and left ventricular ejection fraction increased by 8% ( P <0.001). Along with improvement in the standard deviation of all normal-to-normal R-R intervals (85.63±31.66 ms versus 114.79±38.99 ms; P =0.004) and the standard deviation of the averaged normal-to-normal R-R intervals (82.62±23.03 ms versus 100.50±34.87 ms; P =0.004), the delayed heart/mediastinum (H/M) ratio increased (1.82 [0.58] versus 1.97 [0.59]; P =0.03), whereas the mean (SD) H/M washout rate was reduced (48% [19%] versus 37% [22%]; P =0.01). Twenty-two of 45 study patients responded to CRT, with a reduction of left ventricular end-systolic volume index >15%. Compared with nonresponders, responders had a higher delayed H/M ratio (2.11 versus 1.48; P =0.003) and lower H/M washout rate (37% versus 62%; P =0.003) at baseline. Conclusions— CRT improved sympathetic function. Cardiac sympathetic reserve may be a marker for the reversibility of failing myocardial function.
Effect of Long-Term Right Ventricular Pacing in Young Adults With Structurally Normal Heart
Sagar, Sandeep , Shen, Win-Kuang, Asirvatham, Samuel J. , Cha, Yong‐Mei , Espinosa, Raúl E. , Friedman, Paul A. , Hodge, David O. , Munger, Thomas M. , Porter, Co-burn J., Rea, Robert F., Hayes, David L. , Jahangir, Arshad , Asirvatham, Samuel J

Circulation | April 5, 2010 | Volume: 121 | Issue: 15 | Pages: 1698-1705

10.1161/circulationaha.109.866343 Get It

Background— Right ventricular pacing increases the risk of heart failure in adults with structural heart disease. The impact of prolonged right ventricular pacing in adults without structural heart disease is not fully characterized and may depend on interactions of pacing with abnormal substrate predisposing to ventricular dysfunction. Methods and Results— We assessed the effect of right ventricular pacing in patients who underwent pacemaker implantation for isolated congenital atrioventricular block between 1964 and 2005. To assess for immunologic contribution to cardiac dysfunction, outcomes were compared between patients with (Ab + ) and without (Ab − ) antinuclear antibody during adulthood and an age- and sex-matched Olmsted County, Minnesota, population. Of 103 patients (mean±SD age, 32±19 years), 18 were Ab + . Long-term survival free of new heart failure after pacemaker implantation in isolated congenital atrioventricular block patients was worse than in the matched population ( P <0.001). This difference was attributable to the development of heart failure in 12 Ab + patients (67%; P <0.001), without differences between Ab − patients (2%) and the matched population (2%; P =0.7). Compared with baseline, at last follow-up, left ventricular ejection fraction did not decline in Ab − (53±9% to 57±12%) but decreased in Ab + (52±10% to 38±12%; P =0.03) patients. Survival was similar in Ab − patients and the Minnesota population (98%; P =0.7) but worse in Ab + patients (79%; P <0.01). Conclusions— The natural history of patients with isolated congenital atrioventricular block who require pacing depends upon their antibody status. Antinuclear antibody status was a predictor for the development of heart failure and death. Long-term right ventricular pacing alone does not appear to be associated with development of heart failure, deterioration in ventricular function, or reduced survival in Ab − isolated congenital atrioventricular block patients.