Abstract Introduction We report outcomes for patients in which the IPP became unusable by the patient because of pump difficulties or inadequate fluid volume in the IPP system. Objective We sought to assess outcomes of penile implant single component exchange or fluid instillation in a cohort of patients, challenging the entire device replacement dogma. Methods 17 patients underwent single component exchange by a single surgeon. CT scan was obtained to ensure device integrity, assess for air in the system, and to delineate device details. In cases of pump difficulties, the old pump was removed and replaced with a “classic” Genesis Coloplast pump regardless of initial device brand (“Frankenstein” if brands are mixed). Patients are taught pump rocking techniques and have > 6 months of difficulty before exchange. Patients are warned of auto-inflation as there is no lock out valve in the Genesis pump. For fluid addition to the system, the two old connector collars are separated and sometimes re-used after saline is added to only the cylinders. We never add fluid to the reservoir using a piston syringe for fear of reservoir capsule rupture into adjacent structures. Revisions were copiously irrigated, as of 2022, with Irrisept. Results Pump exchange: 14 patients underwent single component pump exchange secondary to inability for the patient to be able to adequately cycle the device (11 AMS MS, 1 Coloplast Touch). Remarkable differences were noted in pump cycling between office exam (difficult), exam under anesthesia prior to incision (sometimes difficult), and once the pump is removed from its capsule (universally easy). Complications of these 14 patients include 1 fungal infection requiring replacement with a malleable device and one repeat pump exchange (AMS MS - AMS MS - Genesis). Two patients noted non-bothersome minor auto-inflation. The single Coloplast case had a remarkably thickened capsule after a likely low grade infection. All patients can successfully use their devices now. Fluid Addition: Three patients underwent fluid addition to the system. One had a significant proximal aneurysm for which we added 35 ml. A different case had both a pump exchange and 30 ml added to the system as the initial reservoir appeared to have folded cordoning off fluid. The final fluid addition occurred 18 months after initial Coloplast 22+2 cm placement in which the patient very aggressively cycled the device and could not obtain 10/10 erection. 30 ml was added to the system totaling 140 cc. All patients have done well with fluid addition with mean time since surgery of 1 year. Conclusions Pump exchange with genesis pump or simple fluid addition to the system are safe and feasible and successfully restores IPP functionality. The Frankenstein strategy is a viable alternative, although patients must be counseled that auto-inflation may occur. With modern day irrigation techniques and CT confirmation of fluid system integrity, the dogma to replace the entire device may actually carry higher morbidity in some patients. Disclosure No
(260) Further Characterizing Treatment Success with Intralesional Collagenase for Peyronie’s Disease
Abstract Introduction Intralesional Collagenase Clostridium histolyticum (CCH) is approved for men with Peyronie’s Disease (PD). Most studies use curve improvement ≥ 20% to define treatment success. Objective Here, we sought to further characterize objective and subjective treatment outcomes with CCH. Methods We reviewed our prospectively maintained database for all patients who underwent CCH at our institution from 2013 through the present. We specifically identified those who completed four series of CCH (or elected to discontinue prior to completing four series due to satisfactory penile straightening or lack of results) and had available curvature assessment data. Treatment outcomes were broken down by level of curve improvement (0%, 10%, 20%, 30%, and > 40% improvement). Treatment success was also evaluated by improvements in the ability to engage in penetrative sexual intercourse and perceived surgery avoidance. Statistical analyses were performed using JMP Pro 14.1.0 (SAS Institute, Cary, NC). Results 127 patients had complete data available. The mean age was 57 years (SD 8.4). The mean PD duration was 27 months (SD 59). The mean baseline curvature was 66.1O, and the mean post-treatment curvature was 45.1O (p<0001). The mean curvature improvement was 32% (SD 33). 68% of patients achieved a 20% or greater improvement in penile curvature, including 38% who achieved ≥ 40% improvement. 72% (n=48/67) felt that CCH prevented the need for surgery, and 68% reported CCH restored the ability to penetrate. Stretched flaccid penile length (SPL) increased by ≥ 1 cm in 50% of patients who used concurrent penile traction (PTT) and CCH, including 28% of patients who experienced ≥ 2 cm of length gain. In contrast, only 16% of patients who did not perform concurrent PTT had a ≥ 1 cm increase in SPL (p<0.0001). Conclusions CCH may restore the ability to penetrate with intercourse, and most patients feel that CCH prevents the need for surgery. Almost 40% of patients experienced a 40% or greater curvature improvement. However, 13% of patients may go through the entire series with minimal improvement. Concurrent PTT allows for simultaneous penile length gain in some patients. These data are helpful when counseling patients on expected outcomes. Disclosure No