Back to Authors

Antonini, Gabriele

0000-0002-1578-3461

Mayo Clinic

Antonini Urology

Citations 2

(114) Initial Safety Outcomes for Rigicon Infla 10® Inflatable Penile Prosthesis
Wilson, Steven K. , Rossello, M, Wen, L, María, Pedro, Carajal, A, Ralph, David , Carrion, R, Caravajal, A, Perito, Paul , Chung, Eric , Rossello, M, Wen, L, Maria, P, Antonini, Gabriele

The Journal of Sexual Medicine | May 22, 2023 | Volume: 20 | Issue: Supplement_1 | Pages: No page available

10.1093/jsxmed/qdad060.109 Get It

Abstract Introduction A new three-piece inflatable penile prosthesis was introduced in 2019. The Rigicon Infla10® has been implanted in 26 centers by 103 physicians. Clinical investigation for FDA approval in United States will begin in late 2022. Objective We report initial survival from explantation and revision rates for infection, mechanical failure and medical problems. Data was obtained from analysis of Patient Information Forms (PIFs) submitted to the manufacturer. Patient information data was omitted prior to analysis. Methods 319 patients implanted from 1/06/2019 to 12/31/2021 were followed to analyze device durability from revision/removal and rates of reoperation for infection, mechanical failure or medical reason. Results Mean follow-up was 21.2 months with a range of 5-36 months. Mean age was 58.5. 4.38% required removal/revision. Mechanical failure was 2.5%. There were no infections reported and only two (0.6%) medical problems (component out of place). One Peyronie's patient required revision for inadequate straightening (0.03% Three patients (0.9%) requested device removal for dissatisfaction. A total of 95.6% of Rigicon Infla10® was free from explant or revision 13 months from the original implant date. Kaplan Meier analysis revealed cumulative survival of the device at 12, 24 and 36 months was 95.6%, 94.7% and 95.7% until surgical invention. Conclusions While this is a retrospective study derived from volunteered Patient Information Forms, we believe the vast majority of the early Rigicon Infla10® performed prior to 1/2022 were included in the analysis. Early results show initial durability from re-operation equivalent to contemporary, devices. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Rigicon, Boston Scientific, Coloplast.
Initial safety outcomes for the Rigicon Infla10® inflatable penile prosthesis
Wilson, Steven K. , Wen, Lexiaochuan , Rossello, Mariano, Maria, Pedro , Carrion, Rafael , Perito, Paul , Ralph, David , Carvajal, Alejandro , Chung, Eric , Antonini, Gabriele , Ozturk, Metin Ishak

BJU International | January 12, 2023 | Volume: 131 | Issue: 6 | Pages: 729-733

10.1111/bju.15960 Get It

Objective To analyse data from patient information forms (PIFs) submitted to the manufacturer of a new three‐piece inflatable penile prosthesis (IPP), the Rigicon Infla10®, to summarize early outcomes. Methods A retrospective review of PIFs from 319 patients implanted with the IPP between 6 January 2019 and 31 December 2021 was performed to assess device durability and rates of reoperation for infection, mechanical failure or medical reasons. Results The mean ± sd (range) follow‐up was 21.2 ± 11 (5–36) months and the mean ± sd patient age was 58.5 ± 8.7 years. Of the total, 4.4% of devices required removal or revision. Complications included mechanical failure (2.5%) and component migration (0.7%). No infections were observed in this series. One patient (0.4%) required revision for inadequate straightening of Peyronie's disease. Three patients (0.9%) requested device removal because of dissatisfaction. A total of 95.6% of the Rigicon Infla10 devices were free from explant or revision 21 months after the original implant date. Kaplan–Meier analysis showed the rates of cumulative survival of the device at 12, 24, 36 months were 95.6%, 94.7% and 93.7%, respectively. Conclusions The vast majority of the early Rigicon Infla10 IPPs implanted prior to January 2022 were included in this retrospective analysis of volunteered PIFs. These early results demonstrate initial durability from reoperation equivalent to that of other contemporary devices.