Back to Authors

Lee, Justin

0000-0003-2444-0169

Mayo Clinic

Cleveland Clinic

Citations 13

Abstract 9696: Long-Term Outcomes With Abandoning versus Extracting Sterile Leads: A 10-Year Population-Based Study
Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Asirvatham, Samuel J. , Kusumoto, Fred , Lee, Justin

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.9696 Get It

Background: Long-term outcomes of lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) during cardiac implantable electronic devices (CIED) procedures requiring lead addition or replacement remain unclear. Hypothesis: We hypothesized that there is no difference in long-term (10-year) outcomes of LA versus TLE during CIED procedures requiring lead addition. Methods: We performed a retrospective cohort study of a population residing in seven adjacent counties of southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE for sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10-years or until their death were included. Outcomes were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system. Results: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. In long-term follow-up, indications for subsequent lead extraction arose in 9.1% (n=14) of patients with initial LA and 5.3% (n=1) in patients with initial TLE, after an average of 7-years. Moreover, out of 14 patients, who required secondary extraction in the LA cohort, 28.6% did not proceed with the extraction. Of the remaining 10 patients, 60% had clinical success and 40% had a clinical failure with the extraction. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges such as requiring balloon venoplasty or serial dilation (5.2% vs. 5.3%, P=1.0). There was no difference in 10-year survival probability among LA group and TLE group (P=0.64). Conclusion: Indications for subsequent extraction arose in 9.1% of patients with the initial LA approach for sterile leads after an average of 7.3 years and 28.6% did not proceed with the extraction. Of the patients who underwent the subsequent extraction, 60% had clinical success and 40% had a clinical failure. There was no difference in 10-year survival probability between patients with the initial LA approach or TLE approach.
Abstract 11583: Impact of Micra Pacemaker Implantation on Echocardiographic Parameters: A Multi-Center Analysis
Sriramoju, Anil, Elbanna, Mostafa , Seri, Amith Reddy , Fahmy, Mostafa Mahmoud , KoKo, Nway, Sriramoju, Anil , Baqal, Omar J , Ashraf, Hasan, Lee, Justin , Masry, Hicham El

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.11583 Get It

Introduction: Studies on leadless pacemakers (LP) are very limited and they often fail to reflect real population outcomes. Hypothesis: We sought to evaluate the effect of leadless pacemaker implantation on the echocardiographic parameters including ventricular function and valvular competence. Methods: A retrospective review including 162 patients (81 Micra Leadless pacemaker implant and 81 dual-chamber transvenous pacemakers) from 3 centers were included. Follow-up clinical, echocardiographic, and pacing characteristics were obtained over a median of 14+/-2 months. Results: baseline demographics and clinical characteristics were comparable between the 2 groups including age (78.6+/-9.9, Range 35-95) and gender (49 males, 69.5%). Compared to conventional pacemakers, LP patients had worsening tricuspid regurgitation noted on follow-up echo in 59.3% of patients compared to baseline(P<0.001). This difference was independent of the RV pacing percentage and device location. In addition, LP implantation resulted in a reduction of RV function (P=0.003) and left ventricular ejection fraction (P=0.03). The RV Pacing burden in LP patient patients was not associated with a change in LVEF during the follow-up period (95% CI -0.24, 0.20, p = 0.846). Conclusions: LP therapy is associated with worsening tricuspid valve regurgitation and biventricular dysfunction over a mean 1 year of follow-up. Additional prospective randomized studies are warranted to further evaluate these findings.
Peripartum Cardiomyopathy and Associated Arrhythmias: A Contemporary Review
Ibrahim, Ramzi , William, Preethi , Ibrahim, Ramzi , Lee, Justin

No container title available | May 18, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.165286624.47939101/v1 Get It

Peripartum cardiomyopathy is an idiopathic cardiomyopathy that most commonly affects women in the third trimester of pregnancy or in the first five months of the postpartum period. Peripartum cardiomyopathy is associated with a myriad of different findings on electrocardiograms. There is also a risk of supraventricular tachycardia, atrial fibrillation, atrial flutter, and ventricular arrhythmias. This review discusses the prevalence and management of tachyarrhythmias and bradyarrhythmias in peripartum cardiomyopathy.