Human plasma somatostatin-like immunoreactivity (SLI) is heterogeneous. Moreover, human plasma contains a somatostatin-binding protein, enzymes that degrade the peptide, and other poorly characterized substances that interfere in radioimmunoassays of the peptide. Previously described extraction methods only partially circumvent these problems and generally result in less than adequate recovery. The present studies were therefore undertaken to determine whether gel filtration of plasma could be used to avoid these difficulties and provide a means for radioimmunoassay of plasma somatostatin in man. Gel filtration (Sephadex G25) of human plasma and subsequent radioimmunoassay of column eluates using five different antisera uniformly demonstrated two fractions of SLI in plasma. One fraction (peak I) eluted in the void volume and had an apparent molecular weight in excess of 150,000 daltons; this material comprised most of the plasma SLI, did not dilute in parallel with synthetic somatostatin, and decreased immunoprecipitability of both N-tyrosine- and tyrosine-11-125I somatostatin. The second fraction (peak II) coeluted with synthetic somatostatin (apparent mol. wt. 1600 daltons), diluted in parallel with synthetic somatostatin, and did not appreciably degrade either 125I-tyrosylated analogue. Synthetic somatostatin added to plasma was recovered nearly completely (95 ± 3%) in peak II SLI. Infused synthetic somatostatin increased peak II SLI but did not alter peak I SLI. These results demonstrate that gel chromatography of human plasma before assay can be used to circumvent problems of immunoheterogeneity, 0degradation, and nonspecific interference while providing adequate recovery. With this method, mean plasma somatostatin concentrations (peak II SLI) in postabsorptive normal volunteers ranged from approximately 40 to 100 pg/ml, depending on the antibody system used. These concentrations (3–6 × 10−11 M) are of similar magnitude to thosereported to affect reputed target tissues of somatostatin in vitro and are thus consistent with a possible hormonal function for the peptide.
Functional Evaluation of a Bioartificial Pancreas Using Isolated Islets Perifused with Blood Ultrafiltrate
A new bioartificial pancreas, in which rat islets within a Millipore chamber are perifused with blood ultrafiltrate (polyacrylonitrile membrane), has been developed and its function evaluated in vitro and in vivo. Use of ultrafiltration (instead of diffusion) permitted rapid transmission of changes in blood glucose to the islet compartment (less than 10 min). To determine whether ultrafiltrate of Krebs-Ringer bicarbonate buffer (KRBB) and blood could support normal islet Bcell function, insulin secretion of freshly isolated islets in response to a 20-mM glucose challenge was examined during perifusion with KRBB and then with ultrafiltrate produced either from KRBB itself or from blood of normal and streptozotocin-induced diabetic rats. In the latter case, perifusate was reinfused to the animals, whose plasma glucose and insulin were then measured. Insulin responses to glucose were virtually identical when the same islets were perifused with KRBB and then with ultrafiltrate of KRBB (47 ± 12 versus 41 ± 9 ng/100 islets/24 min), or when islets were perifused with KRBB and then with ultrafiltrate produced from blood of normal rats (69 ± 6 versus 73 ± 11 ng/100 islets/24 min). When five diabetic rats were connected to the device containing 600 islets, their plasma glucose decreased from 19.8 ± 1.2 to 6.1 ± 0.5 mM (P < 0.001) within 120 min without overshoot hypoglycemia, and remained normal for up to 6 h. Plasma insulin increased from 2.0 ± 0.1 to 11.4 ± 1.4 ng/ml (P < 0.02) at 30 min and then decreased to 2.9 ± 0.6 ng/ml. After intravenous glucose administration (0.5 g/kg, N = 4), plasma insulin increased twofold within 15 min, and glucose disappearance rates were identical to those obtained in four normal rats (K = 2.13 ± 0.18 versus 2.23 ± 0.09, NS). These results indicate that ultrafiltrate of KRBB and blood can acutely support normal islet B-cell function, and that ultrafiltration can provide satisfactory glucose-insulin kinetics for an implantable closed-loop insulin delivery system, in which nonsyngeneic islets may be protected against immune rejection.
Antisomatostatin Gamma Globulin Augments Secretion of Both Insulin and Glucagon In Vitro: Evidence for a Physiologic Role for Endogenous Somatostatin in the Regulation of Pancreatic A- and B-Cell Function
To assess the effects of endogenous somatostatin on pancreatic islet A- and B-cell function, isolated rat islets were incubated in antisomatostatin γ-globulin to bind endogenously released somatostatin, and the insulin and glucagon secretion of these islets was compared with that of islets incubated in γ-globulin isolated from nonimmune serum. Islets incubated in antisomatostatin γ-globulin released significantly more insulin at 4, 8,16, and 32 mM glucose and significantly more glucagon at 8,16, and 32 mM glucose, P < 0.05–0.005. For glucose-stimulated insulin release the threshold was decreased, the Vmax was increased, but the apparent Km was unaltered; for glucose-suppression of glucagon release the threshold was increased, maximal suppression was decreased, but the apparent Ki was unaltered. The augmentative effect of the antisomatostatin γ-globulin was most prominent at 4 mM glucose for insulin release and at 8 mM glucose for glucagon release, but was not limited to glucose since both insulin and glucagon release stimulated by arginine were also augmented by antisomatostatin γ-globulin. These results provide evidence that endogenous somatostatin may act as a physiologic local regulator of both insulin and glucagon secretion and that its effect on insulin and glucagon secretion is dependent on the prevailing glucose concentration.