Back to Authors

Ryan, Justin

https://orcid.org/0000-0002-5432-1817

Mayo Clinic

University of California San Diego

Citations 5

Creation and Validation of a Novel 3-Dimensional Pediatric Hip Ultrasound Model
Nichols, Francesca R. , Nguyen, Mylinh T., Ekpenyong, Atim, Pade, Kathryn , Skinner, John A. , Ryan, Justin , Skinner, John Andrew , Morris, Jonathan M. , Nguyen, Mylinh T.

Pediatric Emergency Care | July 1, 2024 | Volume: 40 | Issue: 9 | Pages: e216-e220

10.1097/pec.0000000000003155 Get It

Objectives The aim of this study was to create and validate a 3-dimensional (3D) ultrasound model with normal and abnormal pediatric hip joint anatomy that is comparable to a pediatric hip joint in appearance and anatomy and replicates sonographic characteristics of a pediatric hip joint. Methods A 3D rendering of the bone and soft tissue was created from a computed tomography pelvic scan of a pediatric patient. This rendering was modified to include a unilateral joint effusion. The bone was 3D printed with a photopolymer plastic, whereas the soft tissue was cast with a silicone mixture in a 3D-printed mold. The effusion was simulated by injecting saline into the soft tissue cavity surrounding the bone. The ultrasound model was validated by pediatric point-of-care ultrasonographers at an international pediatric ultrasound conference. Results A pediatric hip ultrasound model was developed that simulates both normal and abnormal pediatric hip joint anatomy, each with an appropriately sized, measurable joint effusion. Validation by pediatric point-of-care ultrasonographers showed that the key aspects of a normal pediatric hip joint (femoral physis, sloped femoral neck, and adequate soft tissue) with an identifiable and measurable effusion were included in the ultrasound model. Conclusions In this study, we successfully created a cost-effective, reusable, and reproducible 3D pediatric hip ultrasound model. The majority of pediatric point-of-care ultrasonographers who evaluated the model agreed that this model is comparable to a pediatric patient for the purpose of teaching ultrasound skills and joint space measurement.
Alternative methods for virtual heart transplant—Size matching for pediatric heart transplantation with and without donor medical images available
Plasencia, Jonathan D. , Kamarianakis, Yiannis , Karamlou, Tara , Park, Susan S., Nigro, John J. , Frakes, David , Pophal, Stephen , Lagerstrom, Carl F., Velez, Daniel A. , Zangwill, Steven , Ryan, Justin

Pediatric Transplantation | September 24, 2018 | Volume: 22 | Issue: 8 | Pages: No page available

10.1111/petr.13290 Get It

Abstract Background Listed pediatric heart transplant patients have the highest solid‐organ waitlist mortality rate. The donor‐recipient body weight ( DRBW ) ratio is the clinical standard for allograft size matching but may unnecessarily limit a patient's donor pool. To overcome DRBW ratio limitations, two methods of performing virtual heart transplant fit assessments were developed that account for patient‐specific nuances. Method 1 uses an allograft total cardiac volume ( TCV ) prediction model informed by patient data wherein a matched allograft 3‐D reconstruction is selected from a virtual library for assessment. Method 2 uses donor images for a direct virtual transplant assessment. Methods Assessments were performed in medical image reconstruction software. The allograft model was developed using allometric/isometric scaling assumptions and cross‐validation. Results The final predictive model included gender, height, and weight. The 25th‐, 50th‐, and 75th‐percentiles for TCV percentage errors were −13% (over‐prediction), −1%, and 8% (under‐prediction), respectively. Two examples illustrating the potential of virtual assessments are presented. Conclusion Transplant centers can apply these methods to perform their virtual assessments using existing technology. These techniques have potential to improve organ allocation. With additional experience and refinement, virtual transplants may become standard of care for determining suitability of donor organ size for an identified recipient.
Integration of Hybrid and Single Ventricle Rehabilitation Techniques to Treat a Neonate After Iatrogenic Mitral Injury
Seckeler, Michael D. , Pophal, Stephen , Ryan, Justin , Rao, Rohit , Klewer, Scott E. , Nigro, John J. , Ashfaq, Awais , Ashfaq, Awais , Rhee, Edward K.

World Journal for Pediatric and Congenital Heart Surgery | February 11, 2016 | Volume: 7 | Issue: 4 | Pages: 498-501

10.1177/2150135115604469 Get It

Neonatal critical aortic stenosis is life threatening and requires intervention shortly after birth. Early percutaneous aortic valvuloplasty is generally considered to be an effective way to obtain reliable prograde flow. We describe the integrated use of hybrid, open surgical, and single ventricle rehabilitation techniques to successfully treat a neonate with borderline left-sided cardiac structures, who sustained a complication from balloon aortic valvuloplasty.
Hemodynamic Characterization of Geometric Cerebral Aneurysm Templates Treated With Embolic Coils
Nair, Priya , Chong, Brian W. , Indahlastari, Aprinda , Workman, Christopher , Babiker, M. Haithem, Farsani, Hooman Yadollahi, Baccin, Carlos E. , Frakes, David , Ryan, Justin

Journal of Biomechanical Engineering | November 23, 2015 | Volume: 138 | Issue: 2 | Pages: No page available

10.1115/1.4032046 Get It

Embolic coiling is one of the most effective treatments for cerebral aneurysms (CAs), largely due to the hemodynamic modifications that the treatment effects in the aneurysmal environment. However, coiling can have very different hemodynamic outcomes in aneurysms with different geometries. Previous work in the field of biofluid mechanics has demonstrated on a general level that geometry is a driving factor behind aneurysmal hemodynamics. The goal of this study was to relate two specific geometric factors that describe CAs (i.e., dome size (DS) and parent-vessel contact-angle (PV-CA)) and one factor that describes treatment (i.e., coil packing density (PD)) to three clinically relevant hemodynamic responses (i.e., aneurysmal root-mean-square velocity (Vrms), aneurysmal wall shear stress (WSS), and cross-neck flow (CNF)). Idealized models of basilar tip aneurysms were created in both virtual and physical forms to satisfy two-level multifactorial experimental designs. Steady and pulsatile flow hemodynamics were then evaluated in the virtual models using computational fluid dynamics (CFD) (before and after virtual treatment with finite element (FE) embolic coil models), and hemodynamics were also evaluated in the physical models using particle image velocimetry (PIV) (before and after treatment with actual embolic coils). Results showed that among the factors considered, PD made the greatest contributions to effects on hemodynamic responses in and around the aneurysmal sac (i.e., Vrms and WSS), while DS made the greatest contributions to effects on hemodynamics at the neck (i.e., CNF). Results also showed that while a geometric factor (e.g., PV-CA) may play a relatively minor role in dictating hemodynamics in the untreated case, the same factor can play a much greater role after coiling. We consider the significance of these findings in the context of aneurysmal recurrence and rupture, and explore potential roles for the proposed methods in endovascular treatment planning.
Total artificial heart in the pediatric patient with biventricular heart failure
Park, SS, Smith, BP, Ryan, Justin , Plasencia, Jonathan D. , Osborn, MB, Wellnitz, CM, Southard, RN, Pierce, CN, Arabia, FA, Je, Lane, Frakes, David , Velez, DA, Pophal, SG, Nigro, JJ, Sanders, Don B. , Pierce, C.N., Velez, Daniel A. , Pophal, Stephen

Perfusion | July 19, 2013 | Volume: 29 | Issue: 1 | Pages: 82-88

10.1177/0267659113496580 Get It

Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m 2 , thus, limiting pediatric application of this device. This unique case report shares this pediatric institution’s first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m 2 ) below the recommendation of 1.7m 2 . A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.