Back to Authors

Johnson, Christopher D.

0000-0002-2972-3072

Mayo Clinic

Mayo Clinic

Citations 4

Skeletal Muscle Afferent Inhibition Improves Exercise Tolerance in Heart Failure
Carlson, Alex R. , O’Malley, Kathy A., Bruhn, Eric J., Wolhart, Sarah C., Eisenach, John H., Johnson, Bruce D. , Olson, Thomas P. , Keller‐Ross, Manda L. , Johnson, Christopher D. , Curry, Timothy B. , Joyner, Michael J.

The FASEB Journal | June 21, 2021 | Volume: 29 | Issue: S1 | Pages: No page available

10.1096/fasebj.29.1_supplement.1055.30 Get It

BACKGROUND Increased activation of Group III/IV skeletal muscle afferents is suggested to play a role in exercise intolerance in heart failure (HF). PURPOSE The purpose of this study was to examine if skeletal muscle afferent feedback inhibition improves exercise tolerance in HF. METHODS 8 HF patients [59±8 yr, mean±SD] participated in two randomized incremental recumbent cycling exercise sessions to peak capacity (peak oxygen consumption, VO 2 ). Session 1: The synthetic opioid fentanyl (50 mcg), known to block afferent feedback, was injected intrathecally (INJ) in the lumbar spine (L3‐L4 intervertebral space) prior to exercise. Session 2: Participants were prepared similarly with a sham injection (placebo, PLA). Gas exchange, dyspnea and RPE were measured. RESULTS HF patients exercised for a longer duration (Δ3±3 min, p=0.02) and reached a higher power output (PLA:109±30 vs. INJ:128±34 W, p=0.02) with locomotor afferent inhibition. Additionally, peak VO 2 was non‐significantly greater (PLA:18.7±3.3 vs. INJ:21.8±4.4 ml/kg/min, p=0.10). With INJ workload matched to peak PLA workload, RPE was reduced (PLA:18±2 vs. INJ:15±2, respectively, p=0.005) and dyspnea was lower (PLA:7.5±2 vs. INJ:4.2±1, p=0.003) with no difference in VO 2 (p>0.05). CONCLUSION Inhibition of group III/IV locomotor muscle afferent feedback contributes to improved exercise tolerance and exertional symptoms in HF patients.
Acute slow‐paced breathing increases periods of sympathetic nervous system quiescence (1170.12)
Mozer, Michael T., Wallin, B., Charkoudian, Nisha , Drobish, Justin, Wehrwein, Erica A. , Fadel, Paul J. , Johnson, Christopher D. , Joyner, Michael J.

The FASEB Journal | June 16, 2021 | Volume: 28 | Issue: S1 | Pages: No page available

10.1096/fasebj.28.1_supplement.1170.12 Get It

Slow‐paced breathing is a simple strategy to reduce psychological stress. We tested the hypothesis that slow paced breathing would decrease muscle sympathetic nerve activity (MSNA). Ten young, healthy males were studied. The subjects were instructed to rest supine and breathe normally (baseline) or at six breaths per minute, each for 20 minutes. MSNA was measured (peroneal microneurography) and analyzed 5 minutes into each stage for a steady state measurement. Statistical analysis was completed using one way RM ANOVA and Tukey’s posthoc analysis (reported mean±SEM). Average respiratory rate was 11.9 ± 1.1 breaths/min during baseline and 5.8 ± 0.7 breaths/min during slow‐paced breathing. There was no significant difference from baseline compared to slow paced breathing in MSNA burst frequency (18±2.0 vs 18±2.40 bursts/min), burst incidence (31.2±4.01 vs. 30.4±3.80 bursts/100 heartbeats) or burst area (12.70±2.18 vs 13.02±1.98%). However, there was a change in the pattern of burst firing with a significant increase in quiescent periods between burst clusters during slow paced breathing compared to baseline (6.50±0.61 vs. 3.59±0.41 seconds), which was accompanied by a significant decrease in the number of bursts/cluster (2.9±0.38 vs. 5.6±0.8 bursts). This has physiological relevance since there was a significant decrease in plasma norepinephrine, increase in blood flow, and a reduction in mean arterial pressure during these same periods. These findings indicate that despite no change in burst incidence, slow paced breathing alters the pattern of MSNA firing, which may contribute to favorable cardiovascular changes. Grant Funding Source : Supported by NIH HL‐083947
Tension-Controlled Active Compression Garment for Treatment of Orthostatic Intolerance
Pettys‐Baker, Robert, Schleif, Nicholas, Lee, J. Walter, Utset-Ward, Sophia, Berglund, Mary Ellen, Dunne, Lucy E. , Holschuh, Brad , Kelly, Kevin L. , Johnson, Bruce , Joyner, Michael J. , Joyner, Michael J , Johnson, Christopher D.

2018 Design of Medical Devices Conference | July 30, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2018-6884 Get It

Medical compression garments are used to treat lymphatic disorders or conditions of poor venous return (e.g. orthostatic intolerance). Conventional compression garments, namely elastic compression sleeves and inflatable compression systems, may aid in relief of these conditions but are also limited in usability. Fixed levels of compression in elastic materials may induce challenges in donning/doffing, complicating patient compliance [1]. Compression levels in inflatable systems are customizable, but these garments are also bulky and require a tethered inflation source [2]. We are interested in developing easy-to-don/-doff compression garments using shape memory alloy (SMA) coil actuators that contract with heat from an applied current which can be wrapped around the body to apply compressive forces. More specifically, we use a spring coil formation as described by Holschuh et al. [3]. Further developed in the Wearable Technology Lab at the University of Minnesota, our current SMA compression garment (SMA-CG) design improves upon the work of Duvall et al. [4] presented in previous year’s (2017) Design of Medical Devices Conference, representing a year’s evolution in active compression garment design that integrate actuators made with SMA.
The Design and Development of Active Compression Garments for Orthostatic Intolerance
Duvall, Julia, Granberry, Rachael , Dunne, Lucy E. , Holschuh, Brad , Kelly, Kevin L. , Johnson, Bruce , Johnson, Christopher D. , Joyner, Michael J.

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3480 Get It

Current compression garments are often made from a spandex-type elastic material with static levels of compression and can become uncomfortable and difficult to don/doff [1]. This limits their usability, especially for unhealthy or aging populations. The only current alternative to elastic compression stockings are inflatable compression sleeves that are controllable, but highly immobile and must be tethered to an inflation source [2]. Neither design offers a solution that is simultaneously low profile, mobile, and controllable. Here we present the design and development of compression garments with embedded shape-changing materials that can produce controllable compression without the need for a bulky inflation system. This active materials approach enables dynamic control over the degree, timing and location of compression, and allows for graded, synchronized, pulsed, and peristaltic compression patterns, which provide the medical benefit of moving fluid in the body [2]. Such a design combines the best features of both elastic and inflatable compression garments: a slim, low-profile form factor that is easy to don/doff and provides dynamic control. Shape memory alloy (SMA) coil actuators, as described by Holschuh et al., [3] have the ability to apply compressive forces to the body when paired with passive textiles and wrapped circumferentially around the body. These actuators are engineered to contract when heated, creating controllable forces and displacements that are modulated through an applied current. SMA compression garments (SMA-CG) have important applications, from consumer uses to clinical interventions, including: augmenting venous return for conditions of orthostatic intolerance (e.g., postural orthostatic tachycardia syndrome (POTS)); cardiac rehabilitation in heart failure patients; lymphedema venous insufficiency; reducing deep vein thrombosis (DVT) risk; sports performance; and countermeasures for flight or space flight. While the potential uses for this technology are broad, the basic design is similar across many conditions. Key research areas include: 1) identifying and addressing design considerations relevant to prototype development of SMA-CG; 2) determining the compression thresholds needed to dynamically oppose orthostatic changes; and 3) evaluating the effectiveness of the prototypes for augmented venous return by synchronizing compression during cardiac diastole. Here, we focus on the first question: design of SMA-CG prototypes.