Abstract We provide an elaborate review of cases published between January 2005 and April 2021 on hemophagocytic lymphohistiocytosis (HLH) in HIV patients. Seventy articles describing 81 adult patients (age ≥19 years) were included. The median age was 40 years, and 78% were males. Only 65% were known to have HIV before presentation. CD4 count was ≥200 cells/mm3 in 23%, and HIV viral load was <200 copies/mL in 41%. The lack of meticulous reporting of ≥5 of 8 criteria for HLH diagnosis was evident in a third of cases. At least 1 infectious agent—other than HIV—was believed to trigger HLH in 78% of patients. The most common were Epstein-Barr virus (26%), human herpesvirus 8 (21%), and Histoplasma capsulatum (17%). Sixty percent survived. Among those, 93% received treatment for identified secondary trigger(s), while 51% received HLH-directed therapy. There was significant heterogeneity in the treatment regimens used for HLH.
92. Characteristics and Outcomes of Deep Brain Stimulation Device Related Infections: Experience from Quaternary Centers
Abstract Background Increasing use of deep brain stimulation (DBS) over the past 20 years is paralleled by a rise in DBS infections. There is a paucity of data on the diagnosis, management, and outcomes in such infections. We describe our center’s experience with DBS infections. Methods Adults ( >18 years) diagnosed with DBS associated infection between January 1, 2000 and May 1, 2020 were retrospectively reviewed. Data on patient demographics, clinical presentation, microbiology, and management was collected. Results Seventy cases were identified (table 1). The mean age at diagnosis was 58.9 ± 16.5 years. The bulk were free of comorbidities. Parkinson’s disease and essential tremors were the most common indications for DBS placement. The median time from implantation to infection was 4 months [IQR 1,24]. The neurotransmitter and extension wires were the most frequently infected parts. A microbiological diagnosis was made in 89% of cases, 47% of which were polymicrobial. The most commonly identified organisms were Staphylococcus aureus, Cutibacterium acnes, and coagulase-negative staphylococci. For patients with deep infection, 71% had complete device extraction, 20% partial extraction, and 9% device retention; clinical cure at 3 months occurred in 97%, 64% and 100%, respectively (figure 1). On the other hand, 93% of patients with superficial infection had device retention; cure at 3 months was seen in 64% (figure 2). Suppressive oral antibiotics were rarely used, 45% of patients with partial extraction and 26% with device retention. DBS was reimplanted in 71% of patients after complete extraction and led to reinfection in 30% at 1 year follow up. Median time to reimplantation was 2.7 months. All patients who failed at 3 months in the partial extraction and device retention cohorts subsequently underwent complete device removal leading to clinical cure sustained at 1 year follow up. Conclusion All patients who had complete extraction achieved clinical cure at 3-months follow-up, while high failure rates occurred in those with device retention. Most infections were polymicrobial and predominantly caused by gram-positive pathogens. Thirty percent of patients with re-implantation after complete device extraction developed re-infection within 1 year. Disclosures All Authors: No reported disclosures
57. Evaluation of the 2019 European Heart Rhythm Association International Consensus Document in Patients with Cardiovascular Implantable Electronic Devices Who Develop Staphylococcus aureus Bacteremia
Abstract Background Cardiovascular implantable electronic device (CIED) implantation has markedly increased over the past two decades. Staphylococcus aureus bacteremia (SAB) occurs in patients with CIED and determination of device infection among patients without clinical findings of pocket site infection is often difficult. Our study examines the characteristics, management, and outcomes of SAB in patients living with CIED using 2019 international criteria to define CIED infection. Methods We conducted a retrospective study of patients with CIED who were hospitalized at Mayo Clinic, Rochester, with SAB from January 1, 2012 to December 31, 2019. Patients who met CIED infection criteria following SAB based on the 2019 European Heart Rhythm Association International Concensus Document were identified. A time-to-event analysis was used to determine the impact, if any, of complete device extraction on outcomes. Results Overall, 110 patients with CIED developed SAB and 92 (83.6%) of them underwent transesophageal echocardiogram (TEE). Eighty-eight (80%) had CIED infection with 57 (51.8%) and 31 (28.2%) patients meeeting criteria for definite and possible CIED infections, respectively. Forty-three (75.4%) patients with definite CIED infection underwent complete device extraction. For possible and rejected CIED infection, the rates of complete device extraction were 35.5% and 27.3%, respectively (p< .001 for each). The primary endpoint of a composite of one-year mortality and SAB relapse had a rate that was significantly lower in patients with CIED infection who underwent complete device extraction as compared to that of patients who did not undergo device extraction (25.9% vs. 76.5%, p< .001). No significant difference in outcomes was seen in the rejected CIED infection group (33.3% vs. 62.5%, p =.27). Conclusion The rate of CIED infections following SAB was higher than that reported previously. Increased use of TEE and a novel case definition with broader diagnostic criteria were likely operative, in part, in accounting for the the higher rate of CIED infections complicating SAB. Complete device removal is critical in patients with either definite or possible CIED infection as defined by the 2019 consensus document to improve one-year mortality and SAB relapse rates. Disclosures Larry M. Baddour, MD, Boston Scientific (Individual(s) Involved: Self): Consultant; Botanix Pharmaceuticals (Individual(s) Involved: Self): Consultant; Roivant Sciences (Individual(s) Involved: Self): Consultant Muhammad R. Sohail, MD, Medtronic (Consultant)Philips (Consultant)