Detection of Hypo‐N‐Glycosylation Using Mass Spectrometry of Transferrin
Lacey, Jean M., Bergen, H. Robert, O’Brien, John F.

Current Protocols in Human Genetics | July 24, 2007 | Volume: 54 | Issue: 1 | Pages: No page available

10.1002/0471142905.hg1704s54 Get It

AbstractMany congenital disorders of glycosylation (CDG) can be diagnosed by observing the extent of glycosylation of the abundant serum glycoprotein transferrin (Trf). Trf is an N‐glycosylated protein with two asparagine glycation sites. CDG types I are those genetic defects which occur prior to transfer of the complex oligosaccharide to the acceptor asparagine in the cotranslated polypeptide chain. CDG Ia constitutes by far the most frequent form of CDG and is the result of mutations in the phosphomannomutase gene. CDG Ia and the Ib subtype (Phosphomannoisomerase deficiency) result in low cellular mannose‐1‐phosphate levels, a required precursor for oligosaccharide assembly in the endoplasmic reticulum. The deficiency in oligosaccharides with branched mannose structures is thereafter expressed by the appearance of glycoproteins with unoccupied N‐glycosylation sites (hypoglycosylation). Currently, there have been at least 11 Type I defects, type Ia being by far the most frequently occurring. Most, if not all type I defects result in unoccupied N‐glycation sites. Hypoglycosylated Trf, also known as carbohydrate‐deficient Trf (CDT), can be detected using mass spectrometry (MS) to measure the masses of the serum Trf. The methods for sample preparation using affinity chromatography and MS analysis are described in this unit. Curr. Protoc. Hum. Genet. 54:17.4.1‐17.4.9 © 2007 by John Wiley & Sons, Inc.
Improved Specificity of Newborn Screening for Congenital Adrenal Hyperplasia by Second-Tier Steroid Profiling Using Tandem Mass Spectrometry
Lacey, Jean M., Minutti, Carla , Magera, Mark J , Tauscher, Angela L., Casetta, Bruno , McCann, Mark, Lymp, James, Hahn, Si Houn , Rinaldo, Piero, Matern, Dietrich

Clinical Chemistry | February 23, 2004 | Volume: 50 | Issue: 3 | Pages: 621-625

10.1373/clinchem.2003.027193 Get It

Abstract Background: Newborn screening for congenital adrenal hyperplasia (CAH) involves measurement of 17α-hydroxyprogesterone (17-OHP), usually by immunoassay. Because this testing has been characterized by high false-positive rates, we developed a steroid profiling method that uses liquid chromatography–tandem mass spectrometry (LC-MS/MS) to measure 17-OHP, androstenedione, and cortisol simultaneously in blood spots. Methods: Whole blood was eluted from a 4.8-mm (3/16-inch) dried-blood spot by an aqueous solution containing the deuterium-labeled internal standard d8-17-OHP. 17-OHP, androstenedione, and cortisol were extracted into diethyl ether, which was subsequently evaporated and the residue dissolved in LC mobile phase. This extract was injected into a LC-MS/MS equipped with pneumatically assisted electrospray. The steroids were quantified in the selected-reaction monitoring mode by use of peak areas in reference to the stable-isotope-labeled internal standard. We analyzed 857 newborn blood spots, including 14 blood spots of confirmed CAH cases and 101 of false-positive cases by conventional screening. Results: Intra- and interassay CVs for 17-OHP were 7.2–20% and 3.9–18%, respectively, at concentrations of 2, 30, and 50 μg/L. At a cutoff for 17-OHP of 12.5 μg/L and a cutoff of 3.75 for the sum of peak areas for 17-OHP and androstenedione divided by the peak area for cortisol, 86 of the 101 false-positive samples were within reference values by LC-MS/MS, whereas the 742 normal and 14 true-positive results obtained by conventional screening were correctly classified. Conclusion: Steroid profiling in blood spots can identify false-positive results obtained by conventional newborn screening for CAH.