Back to Authors

Larson, Timothy S.

Mayo Clinic

Mayo Clinic

Citations 25

Perfusion pressure and volume status determine the microvascular response of the rat kidney to NG-monomethyl-L-arginine.
Lockhart, John C. , Larson, Timothy S., Knox, Franklyn G.

Circulation Research | June 12, 2012 | Volume: 75 | Issue: 5 | Pages: 829-835

10.1161/01.res.75.5.829 Get It

This study investigated the role of volume status and perfusion pressure on the hemodynamic response of cortical and medullary renal capillaries to systemic inhibition of nitric oxide. NG-Monomethyl-L-arginine (L-NMMA) was infused intravenously (15-mg/kg bolus and 500-micrograms.min-1.kg-1 infusion), and blood flow in cortical capillaries (QCC) and in descending (QDVR) and ascending vasa recta (QAVR) was measured by fluorescence videomicroscopy in euvolemic and volume-expanded anesthetized Munich-Wistar rats. L-NMMA in euvolemic rats decreased vasa recta blood flow (delta QDVR, 3.97 +/- 0.80 nL/min [P < .01]; delta QAVR, 1.90 +/- 0.39 nL/min [P < .01]; n = 6) and QCC (delta QCC, 0.57 +/- 0.15 nL/min [P < .01]; n = 7) despite increases in renal perfusion pressure (RPP). Fractional excretion of sodium (FENa) remained unchanged. In volume-expanded rats, L-NMMA decreased vasa recta blood flow when RPP increased (delta QDVR, 1.42 +/- 0.79 nL/min [P = .05]; delta QAVR, 1.95 +/- 0.34 nL/min [P < .001]; n = 9) or was held constant by partial aortic occlusion (delta QDVR, 1.19 +/- 0.45 nL/min [P < .05]; delta QAVR, 1.44 +/- 0.40 nL/min [P < .01]; n = 8). QCC was unchanged by L-NMMA when RPP increased (delta QCC, 0.27 +/- 0.20 nL/min; n = 8) but decreased significantly by 0.61 +/- 0.11 nL/min (P < .01, n = 8) when increases in RPP were prevented. FENa increased when RPP increased (delta FENa, 2.47 +/- 0.51%; P < .001) and was held constant (delta FENa, 2.64 +/- 0.46%; P < .001).(ABSTRACT TRUNCATED AT 250 WORDS)
Relation between vasa recta blood flow and renal interstitial hydrostatic pressure during pressure natriuresis.
Farrugia, E, Lockhart, John C. , Larson, Timothy S.

Circulation Research | June 12, 2012 | Volume: 71 | Issue: 5 | Pages: 1153-1158

10.1161/01.res.71.5.1153 Get It

Pressure natriuresis may be mediated through increases in inner medullary vasa recta blood flow (QVR). By means of acute renal decapsulation to prevent increases in renal interstitial hydrostatic pressure (RIHP), the effect of increases in QVR in the presence and absence of changes in RIHP in the natriuretic and diuretic responses to increases in renal perfusion pressure (RPP) was evaluated. Blood flow in descending (QDVR) and ascending (QAVR) vasa recta was determined in the exposed papilla by fluorescence videomicroscopy in anesthetized euvolemic Munich Wistar rats. In rats with intact renal capsules (n = 12), increases in RPP from 101 +/- 0.5 to 132 +/- 2.9 mm Hg caused significant increases in QDVR (from 4.7 +/- 0.9 to 5.5 +/- 0.9 nl/min, p < 0.001) and QAVR (from 2.8 +/- 0.2 to 3.5 +/- 0.2 nl/min, p < 0.001) in association with increases in RIHP (from 4.6 +/- 1.3 to 7.6 +/- 1.3 mm Hg, p < 0.001), urine flow (from 16.2 +/- 2.6 to 20.2 +/- 3.2 microliters.min-1 x g kidney wt-1, p < 0.01), and urinary sodium excretion (from 2.10 +/- 0.38 to 3.36 +/- 0.62 mu eq.min-1 x g kidney wt-1, p < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Importance of Cystatin C Assay Standardization
Voskoboev, Nikolay, Larson, Timothy S., Rule, Andrew D. , Lieske, John C.

Clinical Chemistry | June 11, 2011 | Volume: 57 | Issue: 8 | Pages: 1209-1211

10.1373/clinchem.2011.164798 Get It

Iothalamate Quantification by Tandem Mass Spectrometry to Measure Glomerular Filtration Rate
Seegmiller, Jesse C. , Burns, Bradley E., Fauq, Abdul H. , Mukhtar, Naveen, Larson, Timothy S., Lieske, John C.

Clinical Chemistry | February 19, 2010 | Volume: 56 | Issue: 4 | Pages: 568-574

10.1373/clinchem.2009.133751 Get It

Abstract Background: Glomerular filtration rate (GFR) can be determined by measuring renal clearance of the radiocontrast agent iothalamate. Current analytic methods for quantifying iothalamate concentrations in plasma and urine using liquid chromatography or capillary electrophoresis have limitations such as long analysis times and susceptibility to interferences. We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to overcome these limitations. Methods: Urine and plasma samples were deproteinized using acetonitrile and centrifugation. The supernatant was diluted in water and analyzed by LC-MS/MS using a water:methanol gradient. We monitored 4 multiple reaction monitoring transitions: m/z 614.8–487.0, 614.8–456.0, 614.8–361.1, and 614.8–177.1. We compared the results to those obtained via our standard capillary electrophoresis (CE-UV) on samples from 53 patients undergoing clinical GFR testing. Results: Mean recovery was 90%–110% in both urine and plasma matrices. Imprecision was ≤15% for the m/z 614.8–487.0 and 614.8–456.0 transitions over a 10-day period at 1 mg/L. Method comparison for 159 patient samples (53 clearances) provided the following Passing–Bablok regressions: plasma iothalamate LC-MS/MS (y) vs CE-UV (x), y = 0.99x + 0.36; urine iothalamate LC-MS/MS vs CE-UV, y = 1.01x + 0.31; corrected GFR LC-MS/MS vs CE-UV, y = 1.00x + 0.00. Interfering substances prevented accurate iothalamate quantification by CE-UV in 2 patients, whereas these samples could be analyzed by LC-MS/MS. Conclusions: Iothalamate can be quantified by LC-MS/MS for GFR measurement. This method circumvents potential problems with interfering substances that occasionally confound accurate GFR determinations.
Comparison of Urinary Albumin Quantification by Immunoturbidimetry, Competitive Immunoassay, and Protein-Cleavage Liquid Chromatography–Tandem Mass Spectrometry
Seegmiller, Jesse C. , Sviridov, Denis, Larson, Timothy S., Borland, Timothy M., Hortin, Glen L. , Lieske, John C.

Clinical Chemistry | September 10, 2009 | Volume: 55 | Issue: 11 | Pages: 1991-1994

10.1373/clinchem.2009.129833 Get It

Abstract Background: Increased urinary albumin excretion is a well-documented diagnostic and prognostic biomarker for renal disease. Urinary albumin is typically measured in clinical settings by immunoassay methods. However, neither a reference method nor a urine albumin calibration reference material is currently available. Methods: We quantified urinary albumin in patient samples by using 3 commercially available reagent systems: DiaSorin SPQ™ and Beckman Coulter LX® 20 (immunoturbidimetric), and Siemens Immulite® (competitive immunoassay). Results were compared to values obtained by protein-cleavage liquid chromatography–tandem mass spectrometry (LC-MS/MS). Results: In general, results from the 3 immunoassays agreed with results from LC-MS/MS. However, the SPQ results showed a negative bias across all ranges of albuminuria [(0–200 mg/L, y = 0.91x – 3.74 (CI 0.86–0.96); &gt; 200 mg/L, y = 0.88x – 40.30 (CI 0.76–1.00)], whereas the LX 20 showed minimal bias in the 0–200 mg/L range [y = 0.97x − 88 (CI 0.92–1.02)] and the Immulite assay showed positive bias in the 0–200 mg/L range [y = 1.15x – 4.38 (CI 1.09–1.20)]. Conclusions: These results showed a reasonable quantification of urinary albumin by representative polyclonal and monoclonal immunoassays compared to an LC-MS/MS assay. In addition, the results do not suggest the presence of nonimmunoreactive albumin in urine. However, differences in analytic performance between assays support the need for a reference calibration material and reference method to standardize clinical laboratory measurements of urinary albumin.
Quantification of Urinary Albumin by Using Protein Cleavage and LC-MS/MS
Seegmiller, Jesse C. , Barnidge, David R. , Burns, Bradley E., Larson, Timothy S., Kumar, Rajiv , Lieske, John C. , Kumar, Rajiv

Clinical Chemistry | March 27, 2009 | Volume: 55 | Issue: 6 | Pages: 1100-1107

10.1373/clinchem.2008.115543 Get It

Abstract Background: Urinary albumin excretion is a sensitive diagnostic and prognostic marker for renal disease. Therefore, measurement of urinary albumin must be accurate and precise. We have developed a method to quantify intact urinary albumin with a low limit of quantification (LOQ). Methods: We constructed an external calibration curve using purified human serum albumin (HSA) added to a charcoal-stripped urine matrix. We then added an internal standard, 15N-labeled recombinant HSA (15NrHSA), to the calibrators, controls, and patient urine samples. The samples were reduced, alkylated, and digested with trypsin. The concentration of albumin in each sample was determined by liquid chromatography–tandem mass spectrometry (LC-MS/MS) and linear regression analysis, in which the relative abundance area ratio of the tryptic peptides 42LVNEVTEFAK51 and 526QTALVELVK534 from albumin and 15NrHSA were referenced to the calibration curve. Results: The lower limit of quantification was 3.13 mg/L, and the linear dynamic range was 3.13–200 mg/L. Replicate digests from low, medium, and high controls (n = 5) gave intraassay imprecision CVs of 2.8%–11.0% for the peptide 42LVNEVTEFAK51, and 1.9%–12.3% for the 526QTALVELVK534 peptide. Interassay imprecision of the controls for a period of 10 consecutive days (n = 10) yielded CVs of 1.5%–14.8% for the 42LVNEVTEFAK51 peptide, and 6.4%–14.1% for the 526QTALVELVK534 peptide. For the 42LVNEVTEFAK51 peptide, a method comparison between LC-MS/MS and an immunoturbidometric method for 138 patient samples gave an R2 value of 0.97 and a regression line of y = 0.99x + 23.16. Conclusions: Urinary albumin can be quantified by a protein cleavage LC-MS/MS method using a 15NrHSA internal standard. This method provides improved analytical performance in the clinically relevant range compared to a commercially available immunoturbidometric assay.
Comparison between Immunoturbidimetry, Size-Exclusion Chromatography, and LC-MS to Quantify Urinary Albumin
Shaikh, Aisha , Seegmiller, Jesse C. , Borland, Timothy M., Burns, Bradley E., Ladwig, Paula M. , Kumar, Rajiv , Larson, Timothy S., Singh, Ravinder J. , Lieske, John C. , Kumar, Rajiv

Clinical Chemistry | July 11, 2008 | Volume: 54 | Issue: 9 | Pages: 1504-1510

10.1373/clinchem.2008.107508 Get It

Abstract Background: The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-exclusion HPLC. Methods: We obtained unused clinical urine samples from 150 patients who were stratified by degrees of albuminuria (&lt;20 mg/L, 20–250 mg/L, &gt;250 mg/L) as determined by the immunoturbidimetric assay used in our clinical laboratory (Roche Hitachi 912). Urine albumin was then remeasured via LC-MS and HPLC (Accumin™) assays. Results: The immunoturbidimetric assay, calibrated using manufacturer-supplied serum-derived calibrators (Diasorin), underestimated albumin compared with LC-MS. After calibration with purified HSA, this immunoturbidimetric assay correlated well with LC-MS. HPLC overestimated albumin compared with both LC-MS and immunoturbidimetry. The current LC-MS and HPLC assays both performed poorly at concentrations &lt;20 mg/L. Conclusions: Efforts are needed to establish gold-standard traceable calibrators for clinical assays. LC-MS is a specific method to quantify albumin in native urine when concentrations exceed 20 mg/L, and therefore could be employed for standardization among assays.
Patterns of quantitative sensation testing of hypoesthesia and hyperalgesia are predictive of diabetic polyneuropathy: a study of three cohorts. Nerve growth factor study group.
Dyck, Peter James , Larson, Timothy S., O’Brien, Peter C. , Velosa, Jorge A.

Diabetes Care | March 5, 2007 | Volume: 23 | Issue: 4 | Pages: 510-517

10.2337/diacare.23.4.510 Get It

OBJECTIVE: To test quantitative sensation testing (QST) patterns of hypoesthesia and hyperalgesia as indicators of diabetic polyneuropathy (DPN) and its severity RESEARCH DESIGN AND METHODS: We used Computer-Assisted Sensory Examination IV; characterized the QST results of the foot of each patient in three diabetic cohorts (approximately 1,500 patients) as hyperesthetic (&lt; or = 2.5th percentile), low-normal (2.5th-50th percentiles), high-normal (50th-97.5th percentiles), or hypoesthetic (&gt; or = 97.5th percentile); and tested associations with symptoms, impairments, and test abnormalities. RESULTS: Overall neuropathic impairment was most severe in the pancreas-renal transplant and nerve growth factor cohorts, but it was much less severe in the population-based Rochester Diabetic Neuropathy Study (RDNS) cohort. The frequency distribution of sensory abnormalities mirrored this difference. When the QST spectra of diabetic cohorts were compared with those of the control subject cohort for vibration and cooling sensations, the only abnormality observed was hypoesthesia, which was expressed as an increased number of subjects with values at or above the 97.5th percentile or by an increased percentage of cases with high-normal values. Symptoms and impairments of DPN were significantly more frequent in the subjects with values at or above the 97.5th percentile than in the subjects whose values were between the 50th and 97.5th percentiles. For heat pain (HP) sensation thresholds (intermediate pain severity [HP:5], pain threshold [HP:0.5], and pain-stimulus response slope [HP:5-0.5]), an increased frequency of both hypoalgesia and hyperalgesia was observed (especially in the RDNS cohort). Steeper pain-stimulus response slopes were significantly associated with sensory symptoms, including severity of pain. CONCLUSIONS: 1) Decreased vibratory sensation (hypoesthesia) appears to be characteristic of mild DPN, whereas panmodality hypoesthesia is characteristic of severe DPN. 2) A shift of vibratory and cold detection thresholds (and also of attributes of nerve conduction and a measure of autonomic dysfunction) from low-normal (2.5th-50th percentiles) to high-normal (50th-97.5th percentiles) appears to precede overt expression of DPN and to thereby provide evidence of subclinical abnormality 3) Heat stimulus-induced hyperesthesia (low thresholds) occurs especially in mild DPN, and, because it correlates with DPN symptoms and impairments, it must be attributed to hyperalgesia rather than to supersensitivity Therefore, hypoalgesia or hyperalgesia may be an indicator of early DPN.
Trends in persistent proteinuria in adult-onset diabetes: a population-based study.
Larson, Timothy S., Santanello, Nancy C., Shahinfar, S. , O’Brien, Peter C. , Melton, L. Joseph , Leibson, C. L. , Palumbo, Pasquale J

Diabetes Care | March 5, 2007 | Volume: 23 | Issue: 1 | Pages: 51-56

10.2337/diacare.23.1.51 Get It

OBJECTIVE: This study investigates temporal trends in the prevalence and incidence of persistent proteinuria among people with adult-onset diabetes (age &gt; or =40 years). RESEARCH DESIGN AND METHODS: The complete community-based medical records of all Rochester, Minnesota, residents with a diagnosis of diabetes or diabetes-like condition from 1945 through 1989 were reviewed to determine whether they met National Diabetes Data Group (NDDG) criteria. All confirmed diabetes cases residing in Rochester on 1 January 1970 (n = 446), 1980 (n = 647), and/or 1990 (n = 940) were identified. The medical records of these prevalence cases were reviewed from the time of the first laboratory urinalysis value to the last visit, death, or 1 April 1992 (whichever came first) for evidence of persistent proteinuria (two consecutive urinalyses positive for protein, with no subsequent negative values). Similarly, the medical records of all 1970-1989 diabetes incidence cases (n = 1,252) were reviewed to investigate temporal changes in 1) the likelihood of having persistent proteinuria before the date NDDG criteria was met, i.e., baseline; 2) the risk of persistent proteinuria after baseline; and 3) the relative risk of mortality associated with persistent proteinuria. RESULTS: The proportion of diabetes prevalence cases with persistent proteinuria on or before the prevalence date declined from 20% in 1970 to 11% in 1980 and 8% in 1990. Among the 1970-1989 diabetes incidence cases, 77 (6%) had persistent proteinuria on or before baseline; the adjusted odds declined by 50% with each 10-year increase in baseline calendar year (P&lt;0.001). Among individuals free of persistent proteinuria at baseline, 136 subsequently developed persistent proteinuria; the estimated 20-year cumulative incidence was 41% (95% CI 31-59); the adjusted risk did not differ as a function of baseline calendar year. Survival of individuals with persistent proteinuria relative to those without was reduced but did not differ by baseline calendar year. CONCLUSIONS: The prevalence of persistent proteinuria among people with adult-onset diabetes in Rochester, Minnesota, declined 60% between 1970 and 1990. The decline appears because of a decrease in the proportion of diabetes incidence cases with persistent proteinuria before baseline rather than secular declines in the risk of persistent proteinuria after baseline or secular increases in the risk of mortality associated with persistent proteinuria. Similarity over time in age and fasting glucose at baseline, and at prevalence dates, is evidence that earlier detection of diabetes is not the sole explanation for the decline.
A Liquid Chromatography-Mass Spectrometry Method for the Quantification of Urinary Albumin using a Novel 15N-Isotopically Labeled Albumin Internal Standard
Crow, Frank W., Babić, Nikolina , Lutz, Ward H, Larson, Timothy S., Kumar, Rajiv , Singh, Ravinder , Lütz, W, Lieske, John C. , Kumar, Rajiv

Clinical Chemistry | February 27, 2007 | Volume: 53 | Issue: 3 | Pages: 540-542

10.1373/clinchem.2006.078832 Get It