ABSTRACT Histoplasma and Blastomyces antigen detection assays are commonly used diagnostic tools. However, a high level of cross-reactivity between these antigens prevents definitive pathogen identification by these assays alone. Retrospective analysis of 3,529 patients with Histoplasma and Blastomyces antigen testing performed on the same serum sample yielded an overall percent agreement of 99.3% (3,506 of 3,529; kappa: 0.859) between the two assays, suggesting that use of a single assay to detect both antigens may be an alternative diagnostic approach. We assessed performance of the Gotham BioTech Blastomyces antigen (GBA) enzyme immunoassay (EIA) (Portland, Maine) for detection of Blastomyces and Histoplasma antigens in serum. Comparison to the MiraVista Diagnostics Blastomyces (MVB) EIA showed 100% positive (24 of 24), negative (57 of 57), and overall (81 of 81) percent agreement. Additionally, 171 sera were used to compare the GBA EIA to the MiraVista Diagnostics Histoplasma (MVH) EIA, which showed 91.3% (63 of 69), 98% (100 of 102), and 95.3% (163 of 171) positive, negative, and overall percent agreement, respectively. Among eight patients with discordant GBA/MVH EIA results, seven had additional fungal testing performed, and results suggested that the MVH and GBA results were inaccurate for two and five samples, respectively. Overall, this study suggests that the GBA EIA has a high level of agreement with both of the commonly used, individual Blastomyces and Histoplasma antigen EIAs. By taking advantage of the high level of cross-reactivity between Blastomyces and Histoplasma antigen EIAs, utilization of a single antigen detection assay for these fungi provides an opportunity to optimize test utilization and decrease patient cost while maintaining a high level of diagnostic accuracy.
Use of next-generation sequencing to detect mutations associated with antiviral drug resistance in cytomegalovirus
ABSTRACT Cytomegalovirus (CMV) is a significant cause of morbidity and mortality among immunocompromised hosts, including transplant recipients. Antiviral prophylaxis or treatment is used to reduce the incidence of CMV disease in this patient population; however, there is concern about increasing antiviral resistance. Detection of antiviral resistance in CMV was traditionally accomplished using Sanger sequencing of UL54 and UL97 genes, in which specific mutations may result in reduced antiviral activity. In this study, a novel next-generation sequencing (NGS) method was developed and validated to detect mutations in UL54 / UL97 associated with antiviral resistance. Plasma samples ( n = 27) submitted for antiviral resistance testing by Sanger sequencing were also analyzed using the NGS method. When compared to Sanger sequencing, the NGS assay demonstrated 100% (27/27) overall agreement for determining antiviral resistance/susceptibility and 88% (22/25) agreement at the level of resistance-associated mutations. The limit of detection of the NGS method was determined to be 500 IU/mL, and the lower threshold for detecting mutations associated with resistance was established at 15%. The NGS assay represents a novel laboratory tool that assists healthcare providers in treating patients who are infected with CMV harboring resistance-associated mutations and who may benefit from tailored antiviral therapy.