Background The use of low-titer group O whole blood is increasing. To reduce wastage, unused units can be converted to packed red blood cells. Supernatant is currently discarded post-conversion; however, it could be a valuable transfusable product. The aim of this study was to evaluate supernatant prepared from late-storage low-titer group O whole blood being converted to red blood cells, hypothesizing it will have higher hemostatic activity compared to fresh never-frozen liquid plasma. Methods Low-titer group O whole blood supernatant (n = 12) prepared on storage day 15 was tested on days 15, 21, and 26 and liquid plasma (n = 12) on 3, 15, 21, and 26. Same-day assays included cell counts, rotational thromboelastometry, and thrombin generation. Centrifuged plasma from units was banked for microparticle characterization, conventional coagulation, clot structure, hemoglobin, and additional thrombin generation assays. Results Low-titer group O whole blood supernatant contained more residual platelets and microparticles compared to liquid plasma. At day 15, low-titer group O whole blood supernatant elicited a faster intrinsic clotting time compared to liquid plasma (257 ± 41 vs . 299 ± 36 s, P = 0.044), and increased clot firmness (49 ± 9 vs . 28 ± 5 mm, P < 0.0001). Low-titer group O whole blood supernatant showed more significant thrombin generation compared to liquid plasma (day 15 endogenous thrombin potential 1,071 ± 315 vs . 285 ± 221 nM·min, P < 0.0001). Flow cytometry demonstrated low-titer group O whole blood supernatant contained significantly more phosphatidylserine and CD41 + microparticles. However, thrombin generation in isolated plasma suggested residual platelets in low-titer group O whole blood supernatant were a greater contributor than microparticles. Additionally, low-titer group O whole blood supernatant and liquid plasma showed no difference in clot structure, despite higher CD61 + microparticle presence. Conclusions Plasma supernatant produced from late-storage low-titer group O whole blood shows comparable, if not enhanced, in vitro hemostatic efficacy to liquid plasma. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Proceedings of the 2022 NHLBI and OASH state of the science in transfusion medicine symposium
AbstractBackgroundState of the Science (SoS) meetings are used to define and highlight important unanswered scientific questions. The National Heart, Lung, and Blood Institute (NHLBI), National Institutes of Health, and the Office of the Assistant Secretary for Health (OASH), Department of Health and Human Services held a virtual SoS in transfusion medicine (TM) symposium.Study Design and MethodsIn advance of the symposium, six multidisciplinary working groups (WG) convened to define research priorities in the areas of: blood donors and the supply, optimizing transfusion outcomes for recipients, emerging infections, mechanistic aspects of components and transfusion, new computational methods in transfusion science, and impact of health disparities on donors and recipients. The overall objective was to identify key basic, translational, and clinical research questions that will help to increase and diversify the volunteer donor pool, ensure safe and effective transfusion strategies for recipients, and identify which blood products from which donors best meet the clinical needs of specific recipient populations.ResultsOn August 29–30, 2022, over 400 researchers, clinicians, industry experts, government officials, community members, and patient advocates discussed the research priorities presented by each WG. Dialogue focused on the five highest priority research areas identified by each WG and included the rationale, proposed methodological approaches, feasibility, and barriers for success.DiscussionThis report summarizes the key ideas and research priorities identified during the NHLBI/OASH SoS in TM symposium. The report highlights major gaps in our current knowledge and provides a road map for TM research.
Not as “D”eadly as once thought – the risk of D-alloimmunization and hemolytic disease of the fetus and newborn following RhD-positive transfusion in trauma
AbstractVon Willebrand factor (VWF) is a multimeric glycoprotein with essential roles in primary hemostasis. Patients with von Willebrand disease (VWD), due to quantitative and/or qualitative defects of VWF usually experience mucocutaneous bleeding. Based on the laboratory results of VWF antigen, various VWF activities, factor VIII activity, and VWF multimer patterns, VWD can be categorized as type 1, 2, and 3 VWD. VWF multimer analysis by either manual or semi-automated electrophoresis and immunoblotting is a critical part of the laboratory testing to differentiate type 1, type 2 VWD, and subtypes of type 1 or 2 VWD. The multimer distribution patterns can also help to understand the underlying molecular mechanism of VWF synthesis, multimerization, and clearance defects in VWD. This review will cover VWF synthesis, multimerization, secretion, VWF multimer analysis, and VWF multimer interpretation of various types and subtypes of VWD.
Improved semiautomated detection of TRBC-restricted Sézary cells unveils a spectrum of clonal cluster immunophenotypes
AbstractBackgroundWhole blood (WB) is carried by special operations forces as part of a remote damage control resuscitation strategy. The effects of an underwater mission on the quality and coagulation profile of WB were simulated by exposure to hyperbaric pressures in a chamber.MethodsWB units collected in CPDA‐1 were exposed to three different combinations of hyperbaric pressure and duration of exposure: Group A 153.52 kPa (15.24 msw; 1.52 atm) for 4 h; n = 9, Group B 506.63 kPa (50.29 msw; 5.00 atm) for 1 h; n = 9, Group C 153.52 kPa (15.24 msw; 1.52 atm) for 1 h; n = 7. The following parameters were measured on each unit: prothrombin time/international normalized ratio, activated partial thromboplastin time, thromboelastography and concentration determinations of platelets, lactate, fibrinogen, and lactate dehydrogenase. Each sample underwent baseline, prepressurization, immediate postpressurization, and 6 h postpressurization laboratory testing.ResultsSix hours following hyperbaric exposure, the lactate concentration in group C was higher than prepressurization measurement and the platelet concentration in Group A was lower than prepressurization measurement. There were no changes in any of the other analyzed biochemical, coagulation and thromboelastogram parameters following exposure to hyperbaric stress.DiscussionThese data suggest that pressurization of WB up to 5 atm did not impact parameters tested. Changes observed in lactate and platelet count need further study, as well as complementary testing of red blood cell integrity. Further investigation of the hyperbaric extremes is necessary to determine if there is a damage inducing pressure to which WB should not be exposed.
Artificial Intelligence Enhances Diagnostic Flow Cytometry Workflow in the Detection of Minimal Residual Disease of Chronic Lymphocytic Leukemia
Flow cytometric (FC) immunophenotyping is critical but time-consuming in diagnosing minimal residual disease (MRD). We evaluated whether human-in-the-loop artificial intelligence (AI) could improve the efficiency of clinical laboratories in detecting MRD in chronic lymphocytic leukemia (CLL). We developed deep neural networks (DNN) that were trained on a 10-color CLL MRD panel from treated CLL patients, including DNN trained on the full cohort of 202 patients (F-DNN) and DNN trained on 138 patients with low-event cases (MRD < 1000 events) (L-DNN). A hybrid DNN approach was utilized, with F-DNN and L-DNN applied sequentially to cases. “Ground truth” classification of CLL MRD was confirmed by expert analysis. The hybrid DNN approach demonstrated an overall accuracy of 97.1% (95% CI: 84.7–99.9%) in an independent cohort of 34 unknown samples. When CLL cells were reported as a percentage of total white blood cells, there was excellent correlation between the DNN and expert analysis [r > 0.999; Passing–Bablok slope = 0.997 (95% CI: 0.988–0.999) and intercept = 0.001 (95% CI: 0.000–0.001)]. Gating time was dramatically reduced to 12 s/case by DNN from 15 min/case by the manual process. The proposed DNN demonstrated high accuracy in CLL MRD detection and significantly improved workflow efficiency. Additional clinical validation is needed before it can be fully integrated into the existing clinical laboratory practice.
Revisiting the effects of spectral interfering substances in optical end‐point coagulation assays
AbstractIntroductionHemolysis, icterus, and lipemia (HIL) are common pre‐analytical variables in the clinical laboratory. Understanding their effects on coagulation laboratory results is essential.MethodsHIL effects on the prothrombin time (PT), activated partial thromboplastin time (APTT), dilute Russell's viper venom time (DRVVT), thrombin time (TT), and protein C chromogenic activity (CFx) were evaluated on the ACL TOP 750 optical analyzer and STA‐R Evolution mechanical analyzer (PT and APTT only) by spiking normal donor, patient, and commercial control samples with varying concentrations of hemolysate, bilirubin, or a lipid emulsion. The relative difference or bias compared to the original results was determined.ResultsHemolysis (H) indices up to 900 mg/dL did not affect the APTT, PT, DRVVT Confirm, TT, and CFx; however, H indices above approximately 200 mg/dL resulted in a false‐negative DRVVT screen and screen/confirm ratio in samples with a lupus anticoagulant. There was an artifactual prolongation of the PT and APTT when conjugated bilirubin was dissolved in aqueous solvents and not when it was dissolved in dimethyl sulfoxide. Icterus (I) indices up to 45 mg/dL did not result in significant (>15%) bias for all assays evaluated. The PT and APTT assays failed to produce a robust clot curve when the lipemia (L) index exceeded 6000 milliabsorbance units (mAbs), and the TT and DRVVT assays failed when the L index exceeded 3000 mAbs; the CFx assay was unaffected by lipemia.ConclusionsVerification of the manufacturer's recommended interference thresholds is important since it may avoid inappropriate instrument flagging and/ or sample rejection.