Back to Authors

Mehmedović, Armin

0000-0002-5528-8051

Mayo Clinic

University Hospital for Infectious Diseases, 10000 Zagreb, Croatia.

Citations 2

COVLIAS 1.0Lesion vs. MedSeg: An Artificial Intelligence Framework for Automated Lesion Segmentation in COVID-19 Lung Computed Tomography Scans
Suri, Jasjit S. , Agarwal, Sushant , Chabert, Gian Luca , Carriero, Alessandro , Paschè, Alessio , Saba, Luca , Mehmedović, Armin , Faa, Gavino , Singh, Inder M. , Turk, Monika, Chadha, Paramjit S., Johri, Amer M. , Khanna, Narendra N. , Laird, John R. , Pareek, Gyan , Miner, Martin , Sobel, David , Balestrieri, Antonella , Sfikakis, Petros P. , Tsoulfas, George, Protogerou, Athanase D. , Misra, Durga Prasanna , Agarwal, Vikas , Teji, Jagjit S. , Al-Maini, Mustafa , Dhanjil, Surinder, Rathore, Vijay , Fatemi, Mostafa , Krishnan, Pudukode R., Nagy, F. , Fouda, Mostafa M. , Naidu, Subbaram, Višković, Klaudija , Kalra, Manudeep, Mehmedović, Armin , Faa, Gavino , Sobel, David W , Tsoulfas, George , Protogerou, Athanasios , Agarwal, Vikas , Fatemi, Mostafa , Alizad, Azra , Ferenc, Nagy , Fouda, Mostafa M , Naidu, Subbaram , Viskovic, Klaudija , Misra, Durga Prasanna , Agarwal, Sushant , Suri, Jasjit S. , Danna, Pietro , Saba, Luca , Mavrogeni, Sophie , Kitas, George D. , Nicolaides, Andrew , Sharma, Aditya , Alizad, Azra , Ruzsa, Zoltán

Diagnostics | May 21, 2022 | Volume: 12 | Issue: 5 | Pages: 1283

10.3390/diagnostics12051283 Get It

Background: COVID-19 is a disease with multiple variants, and is quickly spreading throughout the world. It is crucial to identify patients who are suspected of having COVID-19 early, because the vaccine is not readily available in certain parts of the world. Methodology: Lung computed tomography (CT) imaging can be used to diagnose COVID-19 as an alternative to the RT-PCR test in some cases. The occurrence of ground-glass opacities in the lung region is a characteristic of COVID-19 in chest CT scans, and these are daunting to locate and segment manually. The proposed study consists of a combination of solo deep learning (DL) and hybrid DL (HDL) models to tackle the lesion location and segmentation more quickly. One DL and four HDL models—namely, PSPNet, VGG-SegNet, ResNet-SegNet, VGG-UNet, and ResNet-UNet—were trained by an expert radiologist. The training scheme adopted a fivefold cross-validation strategy on a cohort of 3000 images selected from a set of 40 COVID-19-positive individuals. Results: The proposed variability study uses tracings from two trained radiologists as part of the validation. Five artificial intelligence (AI) models were benchmarked against MedSeg. The best AI model, ResNet-UNet, was superior to MedSeg by 9% and 15% for Dice and Jaccard, respectively, when compared against MD 1, and by 4% and 8%, respectively, when compared against MD 2. Statistical tests—namely, the Mann–Whitney test, paired t-test, and Wilcoxon test—demonstrated its stability and reliability, with p < 0.0001. The online system for each slice was <1 s. Conclusions: The AI models reliably located and segmented COVID-19 lesions in CT scans. The COVLIAS 1.0Lesion lesion locator passed the intervariability test.
COVLIAS 1.0 vs. MedSeg: Artificial Intelligence-Based Comparative Study for Automated COVID-19 Computed Tomography Lung Segmentation in Italian and Croatian Cohorts
Suri, Jasjit S. , Agarwal, Sushant , Carriero, Alessandro , Paschè, Alessio , Danna, Pietro , Columbu, Marta, Saba, Luca , Višković, Klaudija , Mehmedović, Armin , Agarwal, Samriddhi, Gupta, Lakshya, Faa, Gavino , Singh, Inder M. , Turk, Monika, Chadha, Paramjit S., Johri, Amer M. , Khanna, Narendra N. , Laird, John R. , Pareek, Gyan , Miner, Martin , Sobel, David , Balestrieri, Antonella , Sfikakis, Petros P. , Tsoulfas, George, Protogerou, Athanase D. , Misra, Durga Prasanna , Agarwal, Vikas , Teji, Jagjit S. , Al-Maini, Mustafa , Dhanjil, Surinder, Rathore, Vijay , Fatemi, Mostafa , Krishnan, Pudukode R., Nagy, F. , Ruzsa, Zoltán , Naidu, Subbaram , Paraskevas, Kosmas I. , Danna, Pietro S C , Tsoulfas, George , Protogerou, Athanasios , Fatemi, Mostafa , Alizad, Azra , Ferenc, Nagy , Ruzsa, Zoltan , Paraskevas, Kosmas I , Misra, Durga Prasanna , Agarwal, Vikas , Faa, Gavino , Mehmedović, Armin , Agarwal, Sushant , Suri, Jasjit S. , Saba, Luca , Mavrogeni, Sophie , Kitas, George D. , Nicolaides, Andrew , Sharma, Aditya , Alizad, Azra , Gupta, Archna , Kalra, Mannudeep K.

Diagnostics | December 15, 2021 | Volume: 11 | Issue: 12 | Pages: 2367

10.3390/diagnostics11122367 Get It

(1) Background: COVID-19 computed tomography (CT) lung segmentation is critical for COVID lung severity diagnosis. Earlier proposed approaches during 2020–2021 were semiautomated or automated but not accurate, user-friendly, and industry-standard benchmarked. The proposed study compared the COVID Lung Image Analysis System, COVLIAS 1.0 (GBTI, Inc., and AtheroPointTM, Roseville, CA, USA, referred to as COVLIAS), against MedSeg, a web-based Artificial Intelligence (AI) segmentation tool, where COVLIAS uses hybrid deep learning (HDL) models for CT lung segmentation. (2) Materials and Methods: The proposed study used 5000 ITALIAN COVID-19 positive CT lung images collected from 72 patients (experimental data) that confirmed the reverse transcription-polymerase chain reaction (RT-PCR) test. Two hybrid AI models from the COVLIAS system, namely, VGG-SegNet (HDL 1) and ResNet-SegNet (HDL 2), were used to segment the CT lungs. As part of the results, we compared both COVLIAS and MedSeg against two manual delineations (MD 1 and MD 2) using (i) Bland–Altman plots, (ii) Correlation coefficient (CC) plots, (iii) Receiver operating characteristic curve, and (iv) Figure of Merit and (v) visual overlays. A cohort of 500 CROATIA COVID-19 positive CT lung images (validation data) was used. A previously trained COVLIAS model was directly applied to the validation data (as part of Unseen-AI) to segment the CT lungs and compare them against MedSeg. (3) Result: For the experimental data, the four CCs between COVLIAS (HDL 1) vs. MD 1, COVLIAS (HDL 1) vs. MD 2, COVLIAS (HDL 2) vs. MD 1, and COVLIAS (HDL 2) vs. MD 2 were 0.96, 0.96, 0.96, and 0.96, respectively. The mean value of the COVLIAS system for the above four readings was 0.96. CC between MedSeg vs. MD 1 and MedSeg vs. MD 2 was 0.98 and 0.98, respectively. Both had a mean value of 0.98. On the validation data, the CC between COVLIAS (HDL 1) vs. MedSeg and COVLIAS (HDL 2) vs. MedSeg was 0.98 and 0.99, respectively. For the experimental data, the difference between the mean values for COVLIAS and MedSeg showed a difference of <2.5%, meeting the standard of equivalence. The average running times for COVLIAS and MedSeg on a single lung CT slice were ~4 s and ~10 s, respectively. (4) Conclusions: The performances of COVLIAS and MedSeg were similar. However, COVLIAS showed improved computing time over MedSeg.