Back to Authors

Kweon, Christopher

0000-0001-6864-4599

Mayo Clinic

Department of Orthopaedics & Sports Medicine, University of Washington, Seattle, Washington.

Citations 2

Reconstructing a Patellar Tendon Rupture Neglected for 14 Years When Anatomic Restoration Is Not Possible
Jurgensmeier, Kevin , Kweon, Christopher Y. , Kweon, Christopher , Jurgensmeier, Kevin

JBJS Case Connector | July 21, 2023 | Volume: 13 | Issue: 3 | Pages: No page available

10.2106/jbjs.cc.23.00016 Get It

Case: This case highlights the utility and outcomes of an Achilles tendon bone-block allograft in reconstructing the patellar tendon of a 44-year-old man in the setting of a high-riding, irreducible patella after a chronic patellar tendon rupture of 14 years. Conclusion: In cases of a neglected patellar tendon rupture with an irreducible high-riding patella, an Achilles tendon bone-block allograft can provide the length and tissue necessary to reconstruct the extensor mechanism. Although reconstruction may not be anatomic, patients can still experience great subjective and objective functional improvement with restoration of the extensor mechanism even after delayed reconstruction.
Capsular Closure Following Hip Arthroscopy for Femoroacetabular Impingement
Chhabra, Anikar , Hassebrock, Jeffrey D. , Kweon, Christopher Y. , Economopoulos, Kostas J. , Chhabra, Anikar , Hassebrock, Jeffrey D , Kweon, Christopher

JBJS Essential Surgical Techniques | November 8, 2021 | Volume: 11 | Issue: 4 | Pages: No page available

10.2106/jbjs.st.20.00037 Get It

Background: Recent literature has suggested that capsular closure following hip arthroscopy restores native hip-joint kinematics and may lead to better patient-reported outcomes, especially in high-level athletes 1–4 . Description: Capsular closure of the hip occurs following standard hip arthroscopy, which typically includes labral repair and osteoplasty of the femoral neck and/or acetabulum accessed through an interportal capsulotomy. Viewing through an anterolateral portal with use of a 70° scope, a suture-passing device loaded with a #2 FiberWire (Arthrex) is passed down into the mid-anterior portal. The suture is then passed through the anterior aspect of the proximal leaflet of the capsulotomy. The suture-passing device is then passed through the distal leaflet, and the previously passed suture is grasped and brought out of the cannula. The capsular bites are typically made 1 cm from the edge of the capsule. This process is repeated 1.5 cm posteriorly to the initially placed suture. Typical capsular closure takes 2 to 3 sutures for complete closure. Once the sutures are passed, they are tied with use of half-hitches and excess suture is cut. Alternatives: Alternatives include capsular plication, which is more frequently performed in the setting of capsular laxity preoperatively or connective-tissue disorders 5,6 . Additionally, there is evidence suggesting that leaving the capsulotomy unrepaired may lead to similar results in select populations 7 . Rationale: This procedure is performed largely secondary to the restoration of native anatomy and kinematics of the hip joint 3,8 . Arthroscopy of the hip requires a capsulotomy in order to access the joint, unlike other, more superficial joints such as the shoulder. Capsular closure is often technically challenging and adds length to the procedure. However, recent literature has shown improved patient-reported outcomes with routine capsular closure specifically among high-level athletes 9,10 . Expected Outcomes: Routine capsular closure has been associated with good mid-term patient-reported outcomes 10 . Patients who undergo hip arthroscopy and routine capsular closure can expect to meet the minimal clinically important difference and the patient acceptable symptomatic state for the modified Harris hip score and the Hip Outcome Score Activities of Daily Living component. Patients who participate in high-level sports activities may experience a quicker return to play and more normal kinematics with routine capsular closure. Important Tips: Clear off the capsule immediately following the capsulotomy. Utilize an over-the-top view to better visualize the capsule. Place the sutures from anterior to posterior.