Association of Noninvasive Rejection Biomarkers with 10-year Kidney Allograft Survival
Taber, David, Heilman, Raymond L. , Poggio, Emilio, Kurian, Sunil Thuruthummal, Zhao, Lihui, Gebregziabher, Mulugeta , Kleiboeker, Steve, Friedewald, John J, Kurian, Sunil M. , Friedewald, John J. , Fleming, James N , Poggio, Emilio , Kurian, Sunil , Zhao, Lihui , Kleiboeker, Steve , Friedewald, John J , Taber, David, Poggio, Emilio D. , Marsh, Christopher L.

Kidney360 | March 3, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.34067/kid.0000001167 Get It

Background The primary objective of this analysis was to assess the association between non-invasive biomarker results within the first 2-years post-kidney transplant and 10-year All Cause Graft Loss (ACGL). Methods CTOT-08 was linked with the Scientific Registry of Transplant Recipients (SRTR) to assess 10-year ACGL. Cox Regression was used to determine the association between gene expression profile (GEP) and donor-derived cell-free DNA (dd-cfDNA) results and ACGL. A Cox Regression with time-varying covariates was used to test associations with ACGL with simultaneous and repeated biomarker results. Results The final landmarked Cox model included clinical acute rejection (aHR 2.58 (1,30,5.13) for 1 rejection, aHR 3.41 (1.07,10.85) for 2 rejections), diabetes (aHR 1.71 (0.99,2.96)), recipient age (aHR 1.02 (1.00,1.04)), the highest quartile of positive GEP (aHR 2.44 (1.45,4.10)) and the highest quartile of positive dd-cfDNA (aHR 2.91 (1.77,4.78)). In the time-varying model, having both biomarkers positive at the same time carried the greatest association with ACGL (aHR 4.29 (2.10,8.76)). Conclusions In this multicenter, prospective analysis of GEP and dd-cfDNA on patient and graft outcomes, an independent association with long-term ACGL was demonstrated. Further, a time-varying analysis demonstrated that two biomarkers with independent methodologies tested at the same time can provide more information than either one alone.
Clinical Value of Peripheral Blood Gene Expression Profile and Donor-Derived Cellfree DNA for Identifying Persistent Rejection
Heilman, Raymond L. , Park, S.H., Rebello, Christabel , Kleiboeker, Steve, Holman, John , Friedewald, John J. , Fleming, James N , Holman, John , Friedewald, John J , Kleiboeker, Steve

Kidney360 | August 14, 2024 | Volume: 5 | Issue: 10 | Pages: 1534-1542

10.34067/kid.0000000000000549 Get It

Key Points Peripheral blood biomarkers may have value in monitoring kidney transplant recipients after treatment of acute rejection. The donor-derived cellfree DNA may be more sensitive to identifying antibody-mediated rejection and gene expression profile may be more sensitive to identifying acute cellular rejection. Background Persistent rejection is an increasingly recognized barrier to long-term kidney allograft survival. A noninvasive method to help identify patients with persistent rejection in need of biopsy would be valuable. Methods This was a post hoc analysis of a multicenter observational study. Patients who had a biopsy-proven acute rejection, had another biopsy within 9 months (270 days), and had a biopsy-paired biomarker sample were included. Results A total of 64 index rejections in 58 patients with repeat biopsies were identified with a median time to repeat biopsy of 100 days. Persistent rejection was present in 61%; 69% of follow-up biopsies were performed in clinically stable patients. Peripheral blood gene expression profile (GEP) demonstrated a sensitivity of 59%, specificity of 76%, positive predictive value (PPV) of 79%, and negative predictive value of 54%. Donor-derived cellfree DNA (dd-cfDNA) demonstrated a sensitivity of 62%, specificity of 86%, PPV of 88%, and negative predictive value of 56%. For repeat biopsies within 90 days of rejection in clinically stable patients (63% of repeat biopsies), both GEP and dd-cfDNA had specificities and PPVs of 100%. GEP was more likely to be positive in T-cell–mediated rejection while dd-cfDNA was more likely to be positive in antibody-mediated rejection. Conclusions Both GEP and dd-cfDNA may have utility in identifying clinically stable patients with persistent rejection in need of biopsy; however, they identify different types of rejections. Clinical Trial registration number: NCT01531257.
Prognostic Biomarkers in Kidney Transplantation: A Systematic Review and Critical Appraisal
Raynaud, Marc , Awadhi, Solaf Al, Louis, Kévin , Zhang, Huanxi , Su, Xiaojun , Goutaudier, Valentin , Wang, Jiali, Demir, Zeynep , Wei, Yongcheng , Truchot, Agathe , Bouquegneau, Antoine , Bailly, É. , Maanaoui, Mehdi , Naser, Sofía , Wang, Changxi , Liu, Longshan , Lefaucheur, Carmen , Riella, Leonardo V. , Collins, Professor Gary S. , Al-Awadhi, Solaf , Bailly, Élodie , Lombardi, Yannis , Giarraputo, Alessia , Naser, Sofia , Divard, Gillian , Aubert, Olivier , Murad, M Hassan , Liu, Longshan , Bestard, Oriol , Naesens, Maarten , Friedewald, John J , Lefaucheur, Carmen , Riella, Leonardo V , Collins, Gary , Ioannidis, John P A , Loupy, Alexandre , Bello, Arnaud Del , Divard, Gillian , Murad, M. Hassan , Bestard, Oriol , Naesens, Maarten , Friedewald, John J. , Ioannidis, John P. A. , Loupy, Alexandre

Journal of the American Society of Nephrology | December 6, 2023 | Volume: 35 | Issue: 2 | Pages: 177-188

10.1681/asn.0000000000000260 Get It

Significance Statement Why are there so few biomarkers accepted by health authorities and implemented in clinical practice, despite the high and growing number of biomaker studies in medical research ? In this meta-epidemiological study, including 804 studies that were critically appraised by expert reviewers, the authors have identified all prognostic kidney transplant biomarkers and showed overall suboptimal study designs, methods, results, interpretation, reproducible research standards, and transparency. The authors also demonstrated for the first time that the limited number of studies challenged the added value of their candidate biomarkers against standard-of-care routine patient monitoring parameters. Most biomarker studies tended to be single-center, retrospective studies with a small number of patients and clinical events. Less than 5% of the studies performed an external validation. The authors also showed the poor transparency reporting and identified a data beautification phenomenon. These findings suggest that there is much wasted research effort in transplant biomarker medical research and highlight the need to produce more rigorous studies so that more biomarkers may be validated and successfully implemented in clinical practice. Background Despite the increasing number of biomarker studies published in the transplant literature over the past 20 years, demonstrations of their clinical benefit and their implementation in routine clinical practice are lacking. We hypothesized that suboptimal design, data, methodology, and reporting might contribute to this phenomenon. Methods We formed a consortium of experts in systematic reviews, nephrologists, methodologists, and epidemiologists. A systematic literature search was performed in PubMed, Embase, Scopus, Web of Science, and Cochrane Library between January 1, 2005, and November 12, 2022 (PROSPERO ID: CRD42020154747). All English language, original studies investigating the association between a biomarker and kidney allograft outcome were included. The final set of publications was assessed by expert reviewers. After data collection, two independent reviewers randomly evaluated the inconsistencies for 30% of the references for each reviewer. If more than 5% of inconsistencies were observed for one given reviewer, a re-evaluation was conducted for all the references of the reviewer. The biomarkers were categorized according to their type and the biological milieu from which they were measured. The study characteristics related to the design, methods, results, and their interpretation were assessed, as well as reproducible research practices and transparency indicators. Results A total of 7372 publications were screened and 804 studies met the inclusion criteria. A total of 1143 biomarkers were assessed among the included studies from blood ( n =821, 71.8%), intragraft ( n =169, 14.8%), or urine ( n =81, 7.1%) compartments. The number of studies significantly increased, with a median, yearly number of 31.5 studies (interquartile range [IQR], 23.8–35.5) between 2005 and 2012 and 57.5 (IQR, 53.3–59.8) between 2013 and 2022 ( P < 0.001). A total of 655 studies (81.5%) were retrospective, while 595 (74.0%) used data from a single center. The median number of patients included was 232 (IQR, 96–629) with a median follow-up post-transplant of 4.8 years (IQR, 3.0–6.2). Only 4.7% of studies were externally validated. A total of 346 studies (43.0%) did not adjust their biomarker for key prognostic factors, while only 3.1% of studies adjusted the biomarker for standard-of-care patient monitoring factors. Data sharing, code sharing, and registration occurred in 8.8%, 1.1%, and 4.6% of studies, respectively. A total of 158 studies (20.0%) emphasized the clinical relevance of the biomarker, despite the reported nonsignificant association of the biomarker with the outcome measure. A total of 288 studies assessed rejection as an outcome. We showed that these rejection studies shared the same characteristics as other studies. Conclusions Biomarker studies in kidney transplantation lack validation, rigorous design and methodology, accurate interpretation, and transparency. Higher standards are needed in biomarker research to prove the clinical utility and support clinical use.
Combining Blood Gene Expression and Cellfree DNA to Diagnose Subclinical Rejection in Kidney Transplant Recipients
Park, Sookhyeon , Guo, Kexin , Heilman, Raymond L. , Poggio, Emilio D. , Kurian, Sunil M. , Kleiboeker, Steve, Weems, Juston C. , Holman, John , Zhao, Lihui , Brietigam, S., Rebello, Christabel , Friedewald, John J. , Friedewald, John J , Kurian, Sunil , Taber, David J. , Marsh, Christopher L. , Kleiboeker, Steve , Sinha, Rohita , Abecassis, Michael M.

Clinical Journal of the American Society of Nephrology | October 7, 2021 | Volume: 16 | Issue: 10 | Pages: 1539-1551

10.2215/cjn.05530421 Get It

Background and objectives Subclinical acute rejection is associated with poor outcomes in kidney transplant recipients. As an alternative to surveillance biopsies, noninvasive screening has been established with a blood gene expression profile. Donor-derived cellfree DNA (cfDNA) has been used to detect rejection in patients with allograft dysfunction but not tested extensively in stable patients. We hypothesized that we could complement noninvasive diagnostic performance for subclinical rejection by combining a donor-derived cfDNA and a gene expression profile assay. Design, setting, participants, & measurements We performed a post hoc analysis of simultaneous blood gene expression profile and donor-derived cfDNA assays in 428 samples paired with surveillance biopsies from 208 subjects enrolled in an observational clinical trial (Clinical Trials in Organ Transplantation-08). Assay results were analyzed as binary variables, and then, their continuous scores were combined using logistic regression. The performance of each assay alone and in combination was compared. Results For diagnosing subclinical rejection, the gene expression profile demonstrated a negative predictive value of 82%, a positive predictive value of 47%, a balanced accuracy of 64%, and an area under the receiver operating curve of 0.75. The donor-derived cfDNA assay showed similar negative predictive value (84%), positive predictive value (56%), balanced accuracy (68%), and area under the receiver operating curve (0.72). When both assays were negative, negative predictive value increased to 88%. When both assays were positive, positive predictive value increased to 81%. Combining assays using multivariable logistic regression, area under the receiver operating curve was 0.81, significantly higher than the gene expression profile ( P <0.001) or donor-derived cfDNA alone ( P =0.006). Notably, when cases were separated on the basis of rejection type, the gene expression profile was significantly better at detecting cellular rejection (area under the receiver operating curve, 0.80 versus 0.62; P =0.001), whereas the donor-derived cfDNA was significantly better at detecting antibody-mediated rejection (area under the receiver operating curve, 0.84 versus 0.71; P =0.003). Conclusions A combination of blood-based biomarkers can improve detection and provide less invasive monitoring for subclinical rejection. In this study, the gene expression profile detected more cellular rejection, whereas donor-derived cfDNA detected more antibody-mediated rejection.