Back to Authors

Lundstrom, Brian Nils

0000-0002-5310-5549

Mayo Clinic

Department of Neurology, Mayo Clinic, Rochester, Minnesota, USA.

Citations 25

Distributed brain co-processor for tracking spikes, seizures and behaviour during electrical brain stimulation
Sladky, Vladimir , Nejedlý, Petr , Brinkmann, Benjamin H. , Kim, Inyong , Louis, Erik K. St. , Gregg, Nicholas M. , Lundstrom, Brian N. , Crowe, Chelsea M. , Attia, Tal Pal , Crepeau, Daniel, Balzekas, Irena , Wheeler, Lydia , Cook, Mark , Sturges, Beverly K., Leyde, Kent, Miller, Kai J. , Křemen, Václav , Mívalt, Filip , Brinkmann, Benjamin H , St Louis, E K , Gregg, Nicholas M , Lundstrom, Brian Nils , Pal Attia, Tal , Marks, Victoria S , Wheeler, Lydia P, Van Gompel, Jamie J , Kremen, Vaclav , Cook, Mark J , Marks, Victoria S. , Cimbálník, Jan , Janča, Radek , Gompel, Jamie J. Van , Denison, Timothy , Worrell, Gregory A.

Brain Communications | May 6, 2022 | Volume: 4 | Issue: 3 | Pages: No page available

10.1093/braincomms/fcac115 Get It

Abstract Early implantable epilepsy therapy devices provided open-loop electrical stimulation without brain sensing, computing, or an interface for synchronized behavioural inputs from patients. Recent epilepsy stimulation devices provide brain sensing but have not yet developed analytics for accurately tracking and quantifying behaviour and seizures. Here we describe a distributed brain co-processor providing an intuitive bi-directional interface between patient, implanted neural stimulation and sensing device, and local and distributed computing resources. Automated analysis of continuous streaming electrophysiology is synchronized with patient reports using a handheld device and integrated with distributed cloud computing resources for quantifying seizures, interictal epileptiform spikes and patient symptoms during therapeutic electrical brain stimulation. The classification algorithms for interictal epileptiform spikes and seizures were developed and parameterized using long-term ambulatory data from nine humans and eight canines with epilepsy, and then implemented prospectively in out-of-sample testing in two pet canines and four humans with drug-resistant epilepsy living in their natural environments. Accurate seizure diaries are needed as the primary clinical outcome measure of epilepsy therapy and to guide brain-stimulation optimization. The brain co-processor system described here enables tracking interictal epileptiform spikes, seizures and correlation with patient behavioural reports. In the future, correlation of spikes and seizures with behaviour will allow more detailed investigation of the clinical impact of spikes and seizures on patients.
EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
Cox, Benjamin C. , Danoun, Omar A. , Lundstrom, Brian N. , Lagerlund, Terrence D., Brinkmann, Benjamin H. , Lundstrom, Brian Nils , Wong-Kisiel, Lily C. , Brinkmann, Benjamin H , Wong‐Kisiel, Lily C.

Brain Communications | November 16, 2021 | Volume: 3 | Issue: 4 | Pages: No page available

10.1093/braincomms/fcab278 Get It

Abstract EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patients and compare EEG source imaging of both ictal and interictal scalp EEG to the seizure onset zone on intracranial EEG. Concordance of EEG source imaging with intracranial EEG was determined on a sublobar level and was quantified by measuring the distance between the source imaging result and the centroid of the active seizure onset zone electrodes. The EEG source imaging results of a subgroup of 26 patients with high density 76-channel EEG were compared with the localization of three experienced epileptologists. Of 87 patients, 95% had at least one analysis concordant with intracranial EEG and 74% had complete concordance. There was a higher rate of complete concordance in temporal lobe epilepsy compared to extratemporal (89.3 and 62.8%, respectively, P = 0.015). Of the total 282 analyses performed on this cohort, higher concordance was also seen in temporal discharges (95%) compared to extratemporal (77%) (P = 0.0012), but no difference was seen comparing high-density EEG with standard (32-channel) EEG. Subgroup analysis of ictal waveforms showed greater concordance for ictal spiking, compared with rhythmic activity, paroxysmal fast activity, or obscured onset. Median distances from the dipole and maximum distributed source to a centroid of seizure onset zone electrodes were 30.0 and 32.5 mm, respectively, and the median distances from dipole and maximum distributed source to nearest seizure onset zone electrode were 22.8 and 21.7, respectively. There were significantly shorter distances in ictal spiking. There were shorter distances in patients with Engel Class 1 outcome from surgical resection compared to patients with worse outcomes. For the subgroup of 26 high-density EEG patients, EEG source localization had a significantly higher concordance (92% versus 65%), sensitivity (57% versus 35%) and positive predictive value (60% versus 36%) compared with epileptologist localization. Our study demonstrates good concordance between ictal and interictal source imaging and intracranial EEG. Temporal lobe discharges have higher concordance rates than extratemporal discharges. Importantly, this study shows that source imaging has greater agreement with intracranial EEG than visual review alone, supporting its role in surgical planning.
Experience and consensus on stimulation of the anterior nucleus of thalamus for epilepsy
Fasano, Alfonso , Eliashiv, Dawn, Herman, Susan T. , Lundstrom, Brian N. , Polnerow, Dara, Henderson, Jaimie M. , Fisher, Robert S. , Lundstrom, Brian Nils , Fisher, Robert

Epilepsia | October 26, 2021 | Volume: 62 | Issue: 12 | Pages: 2883-2898

10.1111/epi.17094 Get It

Abstract Deep brain stimulation of the anterior nuclei of thalamus (ANT‐DBS) is effective for reduction of seizures, but little evidence is available to guide practitioners in the practical use of this therapy. In an attempt to fill this gap, a questionnaire with 37 questions was circulated to 578 clinicians who were either engaged in clinical trials of or known users of DBS for epilepsy, with responses from 141, of whom 58.2% were epileptologists and 28.4% neurosurgeons. Multiple regions of the world were represented. The survey found that the best candidates for DBS were considered those with temporal or frontal seizures, refractory to at least two medicines. Motivations for renewing therapy upon battery depletion were reduced convulsive, impaired awareness, and severe seizures and improved quality of life. Targeting of leads mainly was by magnetic resonance imaging, sometimes with intraoperative imaging or microelectrode recording. The majority used transventricular approaches. Stimulation parameters mostly imitated the SANTE study parameters, except for initial stimulation amplitudes in the 2–3‐V or ‐mA range, versus 5 V in the SANTE study. Stimulation intensity was most often increased or reduced, respectively, for lack of efficacy or side effects, but changes in active contacts, cycle time, and pulse duration were also employed. Mood or memory problems or paresthesias were the side effects most responsible for adjustments. Off‐label sites stimulated included centromedian thalamus, hippocampus, neocortex, and a few others. Several physicians used DBS in conjunction with vagus nerve stimulation or responsive neurostimulation, although our study did not track efficacy for combined use. Experienced users varied more from published parameters than did inexperienced users. In conclusion, surveys of experts can provide Class IV evidence for the most prevalent practical use of ANT‐DBS. We present a flowchart for one protocol combining common practices. Controlled comparisons will be needed to choose the best approach.
Low frequency novel interictal EEG biomarker for localizing seizures and predicting outcomes
Lundstrom, Brian N. , Brinkmann, Benjamin H. , Lundstrom, Brian Nils , Brinkmann, Benjamin H , Worrell, Gregory A.

Brain Communications | October 5, 2021 | Volume: 3 | Issue: 4 | Pages: No page available

10.1093/braincomms/fcab231 Get It

Abstract Localizing hyperexcitable brain tissue to treat focal seizures remains challenging. We want to identify the seizure onset zone from interictal EEG biomarkers. We hypothesize that a combination of interictal EEG biomarkers, including a novel low frequency marker, can predict mesial temporal involvement and can assist in prognosis related to surgical resections. Interictal direct current wide bandwidth invasive EEG recordings from 83 patients implanted with 5111 electrodes were retrospectively studied. Logistic regression was used to classify electrodes and patient outcomes. A feed-forward neural network was implemented to understand putative mechanisms. Interictal infraslow frequency EEG activity was decreased for seizure onset zone electrodes while faster frequencies such as delta (2–4 Hz) and beta-gamma (20–50 Hz) activity were increased. These spectral changes comprised a novel interictal EEG biomarker that was significantly increased for mesial temporal seizure onset zone electrodes compared to non-seizure onset zone electrodes. Interictal EEG biomarkers correctly classified mesial temporal seizure onset zone electrodes with a specificity of 87% and positive predictive value of 80%. These interictal EEG biomarkers also correctly classified patient outcomes after surgical resection with a specificity of 91% and positive predictive value of 87%. Interictal infraslow EEG activity is decreased near the seizure onset zone while higher frequency power is increased, which may suggest distinct underlying physiologic mechanisms. Narrowband interictal EEG power bands provide information about the seizure onset zone and can help predict mesial temporal involvement in seizure onset. Narrowband interictal EEG power bands may be less useful for predictions related to non-mesial temporal electrodes. Together with interictal epileptiform discharges and high-frequency oscillations, these interictal biomarkers may provide prognostic information prior to surgical resection. Computational modelling suggests changes in neural adaptation may be related to the observed low frequency power changes.
Anterior nucleus of the thalamus seizure detection in ambulatory humans
Gregg, Nicholas M. , Marks, Victoria S. , Sladky, Vladimir , Lundstrom, Brian N. , Klassen, Bryan T. , Brinkmann, Benjamin H. , Miller, Kai J. , Gompel, Jamie J. Van , Křemen, Václav , Klassen, Bryan, Messina, Steven A. , Brinkmann, Benjamin H , Van Gompel, Jamie J , Worrell, Gregory A , Kremen, Vaclav , Lundstrom, Brian Nils , Gregg, Nicholas M , Marks, Victoria S , Worrell, Gregory A.

Epilepsia | August 21, 2021 | Volume: 62 | Issue: 10 | Pages: No page available

10.1111/epi.17047 Get It

AbstractThere is a paucity of data to guide anterior nucleus of the thalamus (ANT) deep brain stimulation (DBS) with brain sensing. The clinical Medtronic Percept DBS device provides constrained brain sensing power within a frequency band (power‐in‐band [PIB]), recorded in 10‐min averaged increments. Here, four patients with temporal lobe epilepsy were implanted with an investigational device providing full bandwidth chronic intracranial electroencephalogram (cEEG) from bilateral ANT and hippocampus (Hc). ANT PIB‐based seizure detection was assessed. Detection parameters were cEEG PIB center frequency, bandwidth, and epoch duration. Performance was evaluated against epileptologist‐confirmed Hc seizures, and assessed by area under the precision‐recall curve (PR‐AUC). Data included 99 days of cEEG, and 20, 278, 3, and 18 Hc seizures for Subjects 1–4. The best detector had 7‐Hz center frequency, 5‐Hz band width, and 10‐s epoch duration (group PR‐AUC = .90), with 75% sensitivity and .38 false alarms per day for Subject 1, and 100% and .0 for Subjects 3 and 4. Hc seizures in Subject 2 did not propagate to ANT. The relative change of ANT PIB was maximal ipsilateral to seizure onset for all detected seizures. Chronic ANT and Hc recordings provide direct guidance for ANT DBS with brain sensing.