Back to Authors

Fatemi, Mostafa

https://orcid.org/0000-0002-6603-9077

Mayo Clinic

Mayo Clinic

Citations 137

Linear Arrays for Vibro-Acoustography: A Numerical Simulation Study
Silva, Glauber T. , Greenleaf, James F. , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 1 | Pages: 1-17

10.1177/016173460402600101 Get It

In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave or tone-burst signals at slightly different frequencies. The system beamforming is modeled in a homogeneous and lossless fluid. In this model, the point-spread function (psf) of the system is obtained as the product of the spatial impulse function of each linear array. Three linear array configurations are analyzed for vibro-acoustography systems. Simulations considering 64 elements in each array are performed. Aspects related to clinical applications of vibro-acoustography, such as system spatial resolution, sidelobes, grating lobes and image frame-rate are discussed. It is concluded that linear array transducers can produce acceptable spatial resolution for clinical applications.
On the compressional-shear coefficient of nonlinear elasticity in soft isotropic solids
Dontsov, Egor , Kinnick, Randall R., Guzina, Bojan B. , Urban, Matthew W. , Fatemi, Mostafa

The Journal of the Acoustical Society of America | September 24, 2012 | Volume: 132 | Issue: 3_Supplement | Pages: 1982-1982

10.1121/1.4755313 Get It

Acoustoelasticity is a technique that allows quantification of the elastic nonlinearity coefficients (the so-called third-order moduli) of a material by measuring the variation of the sound speed in different directions (and/or polarizations) versus the applied uniaxial static stress. When dealing with nominally isotropic solids, the variation of the shear wave speed in two orthogonal directions with the applied stress permits the computation of two out of three independent nonlinearity coefficients. To generate the shear wave in an experimental setting, the acoustic radiation force pulse was applied to uniaxially deformed phantoms with strains of up to 30%. The results demonstrate that the compressional-shear coefficient C, which governs the variation of the (linear) shear modulus with hydrostatic pressure was found to vary substantially from one phantom to another, with the highest value observed in an agarose-based phantom. The importance of this nonlinearity parameter resides in the fact that the magnitude of the acoustic radiation force (ARF) in soft solids is proportional to C-1. For consistency, the values of C obtained from the acoustoelasticity experiment are compared to those deduced from the shear wave amplitude via its relationship to the magnitude of the ARF used to generate the shear wave.
Shear wave generation using hybrid beamforming methods
Nabavizadeh, Alireza , Greenleaf, James F. , Fatemi, Mostafa , Urban, Matthew W.

The Journal of the Acoustical Society of America | September 24, 2012 | Volume: 132 | Issue: 3_Supplement | Pages: 1982-1982

10.1121/1.4755312 Get It

Elasticity imaging is a medical imaging modality that measures tissue elasticity to aid in diagnosis of certain diseases. Shear wave-based methods have been developed to perform elasticity measurements in soft tissue. Hybrid beamforming applies both the conventional spherical and axicon focusing to produce a beam for generating a shear wave with increased depth-of-field so that measurements can be made with a plane-like shear wave. We present our aperture design and beam optimization performed using Field II simulations. We varied the number of elements devoted to spherical and axicon focusing as well as the opening angle used for axicon focusing. We tested hybrid beamforming in three elastic phantoms and an excised kidney. We evaluated the shear wave speed measurements accuracy in the phantoms as well as the depth-of-field for each hybrid beam. We compared our results with those from using beams generated using spherical and axicon focusing. Our results show that hybrid beamforming is capable of producing a long narrow beam that performs well when among the 128 elements of transducer, 48 elements are allocated to each axicon portion and 32 elements for spherical aperture while the angle of the axicon aperture is set less than 20.
Abstract 4047: Introducing a novel acoustic imaging tool for breast cancer detection
Whaley, Dana H. , Urban, Matthew M., Greenleaf, James F. , Alizad, Azra , Fatemi, Mostafa

Cancer Research | August 9, 2012 | Volume: 72 | Issue: 8_Supplement | Pages: 4047-4047

10.1158/1538-7445.am2012-4047 Get It

Abstract Objective: This paper introduces an alternative non-invasive and non-ionizing breast imaging tool called vibro-acoustography (VA). This method is based on low-frequency harmonic vibrations induced in the object by the radiation force of ultrasound. Contrast in Vibro-acoustography images represent several properties of the object, including the dynamic characteristics at the audio frequency and scattering and absorption properties at the ultrasound frequency. X-ray mammography and ultrasound are the main imaging modality used today for detection of breast lesions. X-ray mammography, however, is ionizing and its sensitivity is greatly reduced in dense breasts. Ultrasound images suffer from speckles or other or artifact that prevents the physician from delineating the mass lesion from the background tissue. Hence, VA may be used as a stand-alone imaging device or as a tool to provide supplementary information to other existing imaging modalities. Materials & Methods: Matching vibro-acoustography and mammography images of human breast are acquired using a combined mammography/vibro-acoustography machine. Images of various types of breast masses are investigated and their characteristics features are compared. Image features, such as lesion borders, interior texture, and speculation pattern, are studied. Results: Resulting images show soft tissue structures, breast lesions and microcalcifications within breast with high contrast, high resolution, and no speckles. The results have been verified using x-ray mammograms of the breast. Vibro-acoustography images demonstrate that calcified masses normally show sharp borders, benign non-calcified masses have smooth texture, and, in some cases, malignant masses are characterized with spiculation. Conclusion: The encouraging results which are based on the data collected from an ongoing study indicate that the above mentioned image features may be used for differentiation of breast masses and suggest that further development of vibro-acoustography technology may lead to a new clinical tool for various imaging applications. Work supported in part by Grant CA121579-01A1from NIH and Grant BCTR#0504550 from Susan G. Komen Breast Cancer Foundation. Citation Format: {Authors}. {Abstract title} [abstract]. In: Proceedings of the 103rd Annual Meeting of the American Association for Cancer Research; 2012 Mar 31-Apr 4; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2012;72(8 Suppl):Abstract nr 4047. doi:1538-7445.AM2012-4047
Vibro-acoustography of small spheres
Greenleaf, James F. , Chen, Shigao , Fatemi, Mostafa

The Journal of the Acoustical Society of America | July 26, 2012 | Volume: 108 | Issue: 5_Supplement | Pages: 2505-2505

10.1121/1.4743254 Get It

Vibro-acoustography is a method for imaging the acoustic energy emitted from objects in response to an oscillatory radiation force produced by two interfering focused beams of ultrasound [M. Fatemi and J. F. Greenleaf, Science 280, 82–85 (1998)]. To facilitate quantitative study, a model is presented that describes the behavior of an elastic sphere in two plane ultrasound waves of slightly different frequencies. The vibrating velocity and the resulting acoustic emission of the sphere at the difference frequency are derived from the radiation force and the impedance of the sphere. For small steel spheres in water, the velocity and emission are predicted to have a simple relationship with the difference frequency and the size of the sphere. Experiments on small stainless steel spheres of different size are carried out for a number of difference frequencies, with a laser interferometer to measure the velocity of the sphere and a calibrated hydrophone to measure the acoustic emission from the sphere. The experimental results fit the model description well. This means that vibro-acoustography may be useful in quantitative measurement.
On the numerical computation of the acoustic radiation force generated by a modulated sound field
Dontsov, Egor , Guzina, Bojan B. , Chen, Shigao , Fatemi, Mostafa

The Journal of the Acoustical Society of America | October 13, 2011 | Volume: 130 | Issue: 4_Supplement | Pages: 2424-2424

10.1121/1.3654712 Get It

The acoustic radiation force (ARF), which signifies the average transfer of momentum from the sound wave to the propagating medium, is nowadays frequently used to compute the mean displacement field in soft tissues due to the action of a focused ultrasound beam. In situations when the sound field used to generate the ARF is modulated, the latter depends on both spatial and temporal derivatives of the acoustic intensity. Unfortunately, the numerical computation of the nonlinear acoustic solution due to modulated focused ultrasound beam is complicated by the presence of two disparate time scales in the formulation. To deal with the problem, the KZK-type spatial scaling is complemented by its dual-time-scale companion, where the temporal coordinate is split into its “fast” and “slow” components, allowing one to track the ultrasound-scale oscillations and modulation-scale variations separately in the solution. In this case, the nonlinear acoustic solution (and consequently the ARF) can be effectively computed in the “fast” frequency domain and “slow” time domain for any given modulation envelope, transient, or steady-state. The proposed developments are both validated by the experimental results and illustrated via numerical examples that show the effectiveness of the computational scheme.
Vibro-acoustic doppler
Nabavizadeh, Alireza , Urban, Matthew W. , Fatemi, Mostafa , Urban, Matthew W

The Journal of the Acoustical Society of America | October 13, 2011 | Volume: 130 | Issue: 4_Supplement | Pages: 2423-2423

10.1121/1.3654706 Get It

This paper describes the principles and initial experimental results of a new Doppler method called vibro-acoustic Doppler (VAD). VAD uses acoustic response of a moving object to a highly localized dynamic radiation force of ultrasound to measure the velocity of the object. The low frequency radiation force is exerted by two co-focused ultrasound beams with slightly different frequencies. The acoustic response of the object is detected by a hydrophone. A formula that describes the relation between the Doppler frequency shift of the emitted acoustic field and the velocity of the moving object is reported. To verify the theory, experiments are conducted on a moving string and a fluid flow phantom. Results show that the error in velocity measurement is less than 9.1% for either phantom. An advantage of this method over the traditional ultrasound Doppler is that velocity measurement with VAD is almost independent of the angle between the ultrasound beam and motion direction. It is shows that in the worst case, the error is 10.3% for a ±30 deg angle variation. Potential biomedical applications of VAD will be discussed.
Estimation of the complex shear modulus in tissue-mimicking materials from optical vibrometry measurements
Yuan, Huina , Guzina, Bojan B. , Chen, S., Kinnick, Randall R., Fatemi, Mostafa , Chen, Shigao , Fatemi, Mostafa

Inverse Problems in Science and Engineering | September 27, 2011 | Volume: 20 | Issue: 2 | Pages: 173-187

10.1080/17415977.2011.589903 Get It

Vibro-acoustography with rotational liner array transducer.
Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa , Urban, Matthew W

The Journal of the Acoustical Society of America | October 19, 2010 | Volume: 128 | Issue: 4_Supplement | Pages: 2363-2363

10.1121/1.3508388 Get It

Vibro-acoustography with rectilinear raster scanning using confocal or linear array transducers have been reported before. Endo-cavity imaging requires a different type of scanning due to space limitation. This paper describes 3-D endo-cavity vibro-acoustography by a rotating linear array that scans the volume of interest. In this configuration a linear array is used to steer the beam electronically, which is combined with the rotational motion of the transducer to scan the beam in a cylindrical volume. This particular geometry produces special artifacts in the image. One such artifact is non-uniformity in signal power due to angular variations with respect to the hydrophone. Another artifact is related to the geometrical distortion in the image. In this paper, we will present examples of vibro-acoustography images with linear and rotational scanning and describe image characteristics and methods to reduce the artifacts. [Work supported by NIH Grant P50 CA91956P2.]
Beamforming for vibro-acoustography using a 1.75D array transducer.
Urban, Matthew W. , Fatemi, Mostafa , Alizad, Azra , Urban, Matthew W

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1828-1828

10.1121/1.3384241 Get It

Vibro-acoustography is an ultrasound-based imaging modality that maps the acoustic response of an object induced by acoustic radiation force. The method employs two ultrasound beams with frequencies separated by a small difference, typically in the kilohertz range. Using a 1.75D array transducer, which has multiple rows of elements, offers an advantage over linear array transducers because it allows for focusing in the elevation direction. We have performed simulations of different arrangements for the apertures assigned to the two ultrasound frequencies and evaluated resolution and sidelobe levels for different arrangements. However, the large size of the elements produces grating lobes in the transmitted fields. We will describe metrics for evaluating grating lobe levels compared to the main lobe of the transmitted field as a quantitative approach to optimize aperture design. We present experimental measurements of the transmitted field and compare with simulation results. Finally, we present imaging results from phantom experiments. This beamforming study is directed toward improving vibro-acoustography image formation using a General Electric Vivid 7 scanner for breast and thyroid imaging. [Mayo Clinic and two of the authors have potential financial interest related to devices or technology referenced above. Work supported by NIH Grant No. R21CA121579 and AIUM Award No. AIUM-EER#1.]